background image

10

805757 v1.05 06.21 Miniboil Install Instructions

Sleep mode (for BA model only)

The unit can be set to Sleep mode to save energy. If Sleep mode is 
enabled, the unit will switch to Sleep if it has not been used for two 
hours. The water temperature will be maintained at 64 °C. Operation 
of the tap during this time will wake the system from sleep and the 
water will start heating up again. Boiling water is available as soon as 
the red LED shows a steady light.
Press the BLUE lever and the SAFETY button and hold them for about 5 
seconds to enable or disable Sleep mode.

The red LED and the white LED will flash simultaneously to confirm 
that Sleep is enabled. They will flash alternately to confirm that Sleep is 
disabled. 

Long period of non-use

Note: In ambient / warm water, microorganisms can multiply 
faster. It is recommended to leave your drinking water system 
switched on even during long periods of non-use.

If you still want to shut down your drinking water system for an 
extended period of time, proceed as follows:
1.  Turn off the water supply.
2.  Use the tap to dispense ambient and hot water until no more water 

flows to empty the system.

3.  Disconnect the appliance from the power supply.

After prolonged non-use

1.  Reconnect the water supply. Pay attention to any leaks.
2.  Reconnect the appliance to the power supply.
3.  After non-use of several days: Drain at least four litres of ambient 

water from the fitting. If necessary collect the water in a suitable 
container. As soon as the LED in red lever lights up continuously, 
drain hot water. Repeat this process until the LED flashes again.

 

CAUTION! Hot water will be dispensed.

4.  The appliance is now ready for use.

Operation

A font kit is available for this product, sold separately as an  accessory. 
For details of the available font kits, please contact your Zip customer 
service provider. The font installation instructions and mounting 
template are supplied with the font kit. 

Part No. 90915Z00: Font Kit, Chrome

Font installation

Activate / deactivate sleep mode 
(BA model):

Press the blue lever and the Safety 
button and hold them for about 
five seconds.

LEDs light up simultaneously when 
sleep mode is activated.
LEDs light up alternating when 
sleep mode is deactivated.

Содержание Miniboil BA

Страница 1: ...1 805757 v1 05 06 21 Miniboil Install Instructions Installation instructions user manual Zip Miniboil AFFIX PRODUCT LABEL HERE 805757 Models Boiling Ambient Boiling Only...

Страница 2: ...of the appliance when full of water Before Commissioning 1 Check the unit has been secured correctly 2 Flush the supply line before connecting 3 Check all plumbing fittings have been tightened 4 Ensur...

Страница 3: ...lation requirements 5 Special tools required 6 Installation 6 Step A Installing the tap 6 Step B Installing the filter 7 Step C Installing the Command Centre 7 Step D Connecting the water supply 7 Ste...

Страница 4: ...s steam and or boiling water may discharge through a vent outlet at the mouth of the tap If the tap is not installed using the Font pedestal ensure the tap body is located so the tap outlet safely dra...

Страница 5: ...site Sufficient space in the cupboard to install the command centre in accordance with these Installation Instructions NOTE Allow clearance of 50 mm around all sides and 200mm above the command centre...

Страница 6: ...ture seal against the bench sink top A light smearing of silicon sealant on the underside of the spacer will ensure a watertight fit 4 Pass the hoses through the 35mm hole and carefully locate the Hea...

Страница 7: ...essary for efficient operation Adjust cupboard door hinges and attach the supplied silicone door buffers to create a 4 mm air gap between the doors and the cupboard This is the minimum ventilation req...

Страница 8: ...ntre It should be fitted together tightly until a click is felt Failure to fully insert the connector will prevent tap operation Once connected fix the cable to the wall ensuring it is off the floor a...

Страница 9: ...be dispensed All LEDs Fault Flashing there is a fault in the unit In that case switch off the unit for at least 20 seconds If the fault has not been corrected when the unit is switched on again contac...

Страница 10: ...ed as follows 1 Turn off the water supply 2 Use the tap to dispense ambient and hot water until no more water flows to empty the system 3 Disconnect the appliance from the power supply After prolonged...

Страница 11: ...ed on Check for loom connection Slow water recovery after use Unit is in Sleep Mode Possible internal fault Touch Hot lever and wait for Red LED to stop flashing Wait for Red LED to stop flashing Cont...

Страница 12: ...7 The terms Zip and HydroTap are registered trade marks of Zip Water Aust Pty Ltd Zip products described in this publication are manufactured under one or more patents and further patent applications...