Tel: 0345 6 005 005 email: [email protected]  www.zipwater.co.uk

Before making the electrical connection, fill the mains and the appliance with water 

by carefully opening and closing the hot water tap in order to vent completely. 
To ensure a maximum flow, remove any existing aerator from the faucet. Flush the 

warm and cold water pipes each at least for one minute.
After every draining (e.g. after work on the plumbing system or following repairs to 

the appliance), the heater must be re-vented in this way before starting it up again.

If the water heater cannot be put into operation, the temperature cut-out or the 

pressure cut-out may have tripped during transport . Check that the power supply is 

switched off and reset the cut-out, if necessary .

Selection of power rating

Only by authorised specialist, otherwise lapse of guarantee! 

On delivery, the display shows the screen “APPROVED” (see left) . If not, the device 

has already been powered once . In this case, please follow the section “Reinstallation” .
Upon first connection of the appliance to the supply voltage, select the maximum 

power rating . Only after having set the power rating, the heater provides its standard 

operation mode . 
The maximum allowable power rating at installation site depends on the local situa-

tion . It is imperative to observe all data shown in the table “Technical specifications”, 

in particular the required cable size and fuse protection for the electrical connection . 

Moreover, the electrical installation must comply with the statutory regulations of the 

respective country and those of the local electricity supply company (Germany: DIN 

VDE 0100) . 
1 .  Switch on the power supply to the appliance . 
2 .  When switching on the supply voltage for the first time, the display shows the menu 

to select the language . Choose your language, after that the selection of power rat-

ing appears .

3 .  Select the maximum allowable power rating depending on the local situation via 

sensor keys .

4 .  Select “

OK

” to confirm the setting .

5 .  Mark the set power rating on the rating plate .
6 .  After having set the maximum allowable power rating, the heating element will be 

activated after approx . 10 – 30 sec of continuous water flow .

7 .  Open the hot water tap . Check the function of the appliance .
8 .  Explain the user how the instantaneous water heater works and hand over the oper-

ating instructions .

9 .  Complete the product registration card and return it to Zip or register the product 

on line at www .zipwater .co .uk/product-registration .

7. Initial operation

SDB

STB

Multiple Power System MPS

®

:

The rated capacity of DEX Next (max . 

power consumption) is 27 kW / 400 V and 

can be changed internally to 24 kW, 21 kW 

or 18 kW .
The rated capacity of DEX 12 Next is 

11 .5 kW at 230 V and can be changed 

internally to 8 .8 kW

Содержание InLine DEX Next

Страница 1: ...umber DEXNext DEX12Next Electronicallycontrolledinstantaneouswaterheaters 1 Installation instructions user manual 9120 34378 v1 00 Sept 2020 ZIP DEX Next DEX12 Next Technical support Tel 0345 6 005 00...

Страница 2: ...12 Installation instruction 1 Overview 13 2 Technical specifications 14 3 Dimensions 14 4 Installation 15 Installation site 15 Mounting accessories 15 Installing the wall bracket 16 Installing connect...

Страница 3: ...fittings and taps may be very hot when the appliance has been in use for some time The values stated on the rating plate must be observed In case of malfunction disconnect the mains power supply immed...

Страница 4: ...pressure of 0 2 to 0 4MPa 2 4bar The appli ance must not be subjected to pressure exceeding 1 0MPa 10bar The appliance must only be used when correctly installed and in perfect working order The appli...

Страница 5: ...nd where collected data can be read out The inlet temperature can be up to 70 C so that operation in connection with reheat ing e g in solar systems is possible It is possible to use the instantaneous...

Страница 6: ...ations Preset applications can be selected here Simply tap on the right sensor key to open the selection Tap on the sensor key under an application symbol to activate it The temperatures are set at th...

Страница 7: ...iance and dis played in graph format Water consumption Power consumption Total consumption costs Select or to scroll through the different periods The consumptions are dis played in diagrams over a pe...

Страница 8: ...own electricity supplier Water price currency m Specify the water price of your own water supplier Load Shedding no function for DEX12 Next If further three phase appliances are connected a load shed...

Страница 9: ...erature you need on the appliance and open the hot water tap Once you feel that the water is too hot do not add any cold water and instead enter a lower temperature on the appliance If you were to add...

Страница 10: ...hows error symbol The appliance has detected an error Switch fuses off and on If sym bol wrench is still indicated contact customer service Flow rate of hot water too weak Outlet fitting dirty or calc...

Страница 11: ...onsumption g Additional load profile the appropriate energy efficiency and the annual power consumption if applicable h Temperature setting for the temperature controller i Sound power level internal...

Страница 12: ...ider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage resulting...

Страница 13: ...re cut out SDB Connecting terminal DEX Next 3 PE DEX12 Next 1 N PE Frame Cold water connection Fine filter Water splash protection sleeve DEX Next hood Non return valve Flow sensor Thermal sensor Ther...

Страница 14: ...at t 38K 4 5 3 3 5 9 2 4 3 9 2 2 6 8 10 7 2 7 9 12 3 2 9 0 2 13 8 2 10 2 2 Rated volume 0 4l Rated pressure 1 0MPa 10bar Connecting type pressure resistant pressureless Heating system Bare wire heati...

Страница 15: ...the wiring could be installed surface mounted Extension kit UDX Art no 34110 RDX RDX3 is necessary The instant water heater can be installed by means of this extension kit if the water connections ar...

Страница 16: ...oles in the template fit over the double nipples Mark the drill holes according to the template and drill them using a 6mm drill Insert the included dowels 3 Pull down the faceplate and unscrew the ma...

Страница 17: ...y slight cor rections are possible by carefully bending the threaded rod of the wall bracket However it must be possible to screw on the water connection pipes of the appli ance without applying force...

Страница 18: ...ater flow reducer D into the hot water connection piece The hot water and cold water connectors must then be screwed into the inch union nut of the appliance inlet and outlet pipe together with the in...

Страница 19: ...s to check the correct operation of the load shedding relay at low appliance output 35 degree celsius setpoint and low water flow rate Mode 2 must be selected if the load shedding relay flickers Only...

Страница 20: ...itched off prior to electrical connection 1 Open the prepared breaking point S in the upper part of the appliance by pressing with a blunt implement e g srewdriver For surface mounted connection cable...

Страница 21: ...rating at installation site depends on the local situa tion It is imperative to observe all data shown in the table Technical specifications in particular the required cable size and fuse protection...

Страница 22: ...to 55 C if it is connected to a show er The temperature limit must be set to a value less or equal 55 C in the setting menu in consultation with the customer and the lock level must be activated When...

Страница 23: ...filiated warm water tap valve several times until air no longer emerges from the pipe 9 Fit the hood of the appliance Then switch on the power again e g via activating the fuses The cold water connect...

Страница 24: ...8 v1 00 Sept 2020 ZIP DEX Next DEX12 Next Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk ZipWaterUK TrafalgarHouse Rash sGreen Dereham Norfolk NR191JG 034560...

Отзывы: