![Zip InLine CEX-U Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/zip/inline-cex-u/inline-cex-u_installation-instructions-and-user-manual_3984925022.webp)
18
Installation instructions & user manual
9120-25693 v3.00 Oct 2018 - ZIP CEX
Technical support
Tel: 0345 6 005 005 email: [email protected] www.zipwater.co.uk
OPERATION
Temperature setting
Select preset temperature
A1
A2
B1
B2
Store temperature
2
Press
≥ 3 sec
Display of new value
(e.g. 43 °C)
Set required
temperature
(e.g. 43 °C)
4
3
1
Temperature limit on
+
Press
≥ 3 sec
1
2
Set temperature
1
–1 °C
+1 °C
Convenience zone 35,0..42,0 °C
1
–0,5
°C
+0,5 °C
Programme buttons
This instantaneous water heater is equipped with an
optional temperature limiting function. This scalding
protection is deactivated in the factory setting.
• Switch on: Select the limit tempe ra ture, then press
and simul taneously for at least 3 sec. The
dis play briefly confirms the activation by “
HI
“.
• Switch off: press program key and
simultaneously for at least 3 sec. The display
briefly confirms the deactivation by “
--
“.
Temperature limitation
To set the required temperature gradually to a lower
or higher value, use the arrow keys and .
• Pressing a key once briefly changes the
temperature by 0.5°C between 35°C and 42°C
and by 1°C outside that range.
• Pressing a key for a longer time changes the
temperature continuously.
Note: If temperature is set below 20 °C with arrow
key the display shows “
--
“ and the appliance
switches off the heating function.
Note: If the water heater supplies a shower, the
maximum temperature was reduced during initial
operation. This limitation cannot be exceeded.
The two programme buttons allow to quickly
select the preset temperature. When pressing a
programme key, the preset temperature is selected
and displayed. The factory setting for programme
is 35 °C and for programme it is 48 °C. To assign
settings for the programme keys:
• Prolonged pressing of the programme key stores
the previously selected temperature. The display
changes from ”
P1
” or “
P2
“ to the newly stored
temperature value. This newly set temperature
is now available each time you press the
corresponding program key.