Zip Hydro Tap Installation and Operating Instructions - 81759 - February 2013 v2.01
Page 11 of 16
Auxiliary Fan Attachment
Auxiliary fan
connection
Cold water
connection
Mains Electrical Power
connection
The HydroTap is equipped with an auxiliary fan connection point on the side
panel close to the cold water inlet / flex and plug area. The fan kit is available
as a spare part. The fan operates in parallel with the Condensor fan helping
to remove heat from the cupboard space. This fan should be purchased and
connected to the HydroTap if the airfow characteristics of the cupboard space
are inadequate for the effective removal of hot air thereby adversly affecting
the operation of the HydroTap.
The fan can be installed so that it extracts air from, or forces air into the
cupboard space, whichever is the most effective for your installation.
Application of the fan is of paramount importance in situations where the
cupboard space reaches temperatures greater than 35ºC.
The exhaust fan kit must be fitted, when supplied with the appliance.
Tap Control Loom
connections
Set the Cold water dispensing times
The ability to change the maximum dispensing time for the Cold water has
been introduced. The default settings for the maximum dispensing times is 15
secs. The ability to change the Cold dispensing times between 5 to 15 secs, in
increments of 1 sec, is acessible through the Menu screen on the LCD.
Scroll through the Menu until the Dispense Cold screen is displayed, then use
the adjust buttons to set the required dispensing time for the Cold Water.