SECTION 8 LCD SCREEN
8.7.6 Dispense times
The ability to change the maximum
dispensing time for both the hot and
cold water has been introduced. The
default settings for the maximum
dispensing times is 15 seconds. The
operator may change both the hot and
cold dispensing times from 5 to 15
seconds, in increments of 1 second.
•
Press the [MENU] button for main
menu.
•
Press the [Settings] button.
•
Enter your 4-digit password and
press [Enter].
•
Press the [Dispense Time] button.
•
Select the option to change and
scroll using the up and down
arrow keys.
The HydroTap
G4 notifies when filter replacement is due. If you notice one of
the following, you will need to change the filter.
•
The white change filter light will flash and remain so until reset.
•
The filter percentage will show 0% on the home screen.
Note
Depending on local water quality conditions and usage, the filter may
require changing anywhere from 1,000 Ltrs to 10,000 Ltrs. You may also
need to replace the filter if you notice unpleasant odours or tastes.
Some water may drip from the filter head (socket) during replacement. Keep
a towel handy to dry up any drips.
•
Open the door of the Command Centre.
•
Relieve system pressure via the filter flush stop cock, a quick open and
close will do. Use the bucket to catch the discharge.
•
Grasp filter cartridge, rotate the cartridge a quarter turn clockwise, then
gently pull down.
SECTION 9 FILTER MAINTENANCE
9.1 Water filter
9.2 Water filter change