802265US v1.27 06.21 BCS, BCS100-75 Install Instructions

Section 3 - CO

2

 Cylinder

STORAGE  WARNING: 

CO

2

 gas cylinders must be installed in an open plan area or in an enclosed room, with a volume no less than 

50 cubic metres (65 cubic yards) for each 2.6kg (6lb) of stored gas. If more than 1 gas cylinder containing 

CO

2

 is present within the same location, the recommended ventilated area should be in proportion to the 

number of gas cylinders stored in that location. A ventilated area is a non-enclosed area which could include 

the kitchen, living room etc. See gas bottle and MSDS sheet for a complete list of warnings.

3.1 

Secure the cylinder cradle:

After marking out the cradle location, secure it to a suitable wall, within 3 feet of the Command Center. Make 

sure the gas bottle, regulator and cradle assembly can comfortably fit, with sufficient clearances, before 

securing the cradle inside the cabinet. Due to regulatory requirements the gas bottle must be stored securely 

and in an upright position. Secure the bottle with the hook-and-loop straps provided.

3.2

 Connect the regulator:

After removing all packing material, fit the regulator to the gas bottle as shown in the diagrams. Ensure the 

plastic seal is fitted securely inside the large chrome nut, before attaching to the gas bottle. If the plastic seal 

is not an easy fit over the spigot, soak it in hot water, before re-applying. Do not force the seal to fit. 
Turn the regulator OFF by rotating the regulator knob, all the way out, in an anti-clockwise direction.

NOTE:

 Two plastic seals are supplied with a new regulator. Only one is required, the other is supplied as 

a spare part. 

3.3

 Connect the gas hose: 

Connect the braided gas hose to the top of the Command Center via the John Guest fitting marked ‘Gas IN’  

Then connect the threaded end to the regulator (Do not lose the small sealing olive). When commissioning, 

first, turn the regulator, grey knob, all the way out (anticlockwise). Then turn the gas ON by rotating the black 

knob on top of the cylinder, anti-clockwise. Finally, adjust the outlet pressure by rotating the grey regulator 

knob in a clockwise direction, to 3.0±0.1 bar (39±1 psi) (green zone) 

NOTE:

 The arrow should sit in the green zone of the regulator gauge; it should not fall in the red or yellow 

sections. 

3.4

 Test for gas leaks:

When commissioning, use soapy water to perform a leak test. Apply the soapy water to the gas connections 

using a sponge or brush. If any bubbles appear and grow, there is a gas leak at the connection. Clean away 

the soapy residue and tighten or refit the leaking connection. Make sure the gas is turned off when tightening 

or refitting the leaking connection. 
Fit the gas bottle into the cradle and secure with the Hook-and-loop strap. Ensure the bottle is in an upright 

position.

NOTE:

 Care must be taken when working with high pressure carbon dioxide, and in no cases should the 

normal operating pressure of 3.0±0.1 bar (39±1 psi) be exceeded.

!

Содержание HydroTap BCS Series

Страница 1: ...27 06 21 BCS BCS100 75 Install Instructions Page 1 of 36 BCS100 75 and BCS Series Zip HydroTap Installation and Operating Instructions Scan QR Code to download the latest version of this document Eng...

Страница 2: ...before installing the Command Center The installation procedure for each of the faucets is detailed in the Faucet Installation instruction book supplied with the faucet For all operational features o...

Страница 3: ...s cylinder Section 3 CO2 Cylinder 3 1 Secure the cylinder cradle 14 3 2 Connect the regulator 14 3 3 Connect the gas hose 14 3 4 Test for gas leaks 14 STEP 4 Install the Command Center Section 4 Comma...

Страница 4: ...unter cabinet supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the Command Center has been installed correctly 2 Check all plu...

Страница 5: ...water and an immersion heating element to boil the water and all utilise a CO2 gas cylinder to carbonate the chilled water Depending on the model these units will dispense boiling water factory set t...

Страница 6: ...ction Venting Sometimes steam and or condensed droplets may discharge through a vent outlet at the faucet If the faucet is not installed using the Font pedestal ensure the faucet body is located so th...

Страница 7: ...ocated near or cleaned with water jets 7 Zip HydroTaps are not to be exposed to the elements of nature 8 Due to the process of continuous improvement Zip reserves the right to change details mentioned...

Страница 8: ...ent 1x Outlet vent 9x Screws 1x Installation Instructions this book and 1x User Guide 1x CO2 gas cylinder regulator assy Major components and accessories Accessories Description Softener and head asse...

Страница 9: ...been certified by IAPMO R T against NSF ANSI Standard 372 for low lead requirement NSF ANSI Standard 42 NSF ANSI Standard 53 CSA B483 1 ASSE 1023 and ASSE 1087 This will deliver the required bacterios...

Страница 10: ...ection point and the stop cock will not be obstructed when the Command Centers are installed For the Celsius All In One an external hot and cold water supply will be required For other faucets the sys...

Страница 11: ...saw and a 12mm Drill Keyhole or Wall Board saw 2 1 Ventilation for All Models Proper air circulation must be provided for all models The system will operate correctly only if the recommended air gaps...

Страница 12: ...ing temperatures then the inlet vent and door outlet vent See item D below will need to be fitted Alternatively a fan kit may be installed using the AUX din plug of the right hand side of the applianc...

Страница 13: ...let and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cabinet space 3 Fit the inlet vent as shown and secure with 5 screws 4 Fi...

Страница 14: ...water before re applying Do not force the seal to fit Turn the regulator OFF by rotating the regulator knob all the way out in an anti clockwise direction NOTE Two plastic seals are supplied with a n...

Страница 15: ...for leaks 4 If any bubbles appear the joint will need to be resealed CO2 Regulator Leak Test Pressure regulating knob ON OFF knob Green zone Relief valve NOTE Be careful not to lose the small sealing...

Страница 16: ...etermine which bypass position you need for your product Section 4 Command Center Installation A Rotate 90 only 1 2 3 4 NOTE Before installation determine whether a water softener or an external filte...

Страница 17: ...le 2 Remove any swarf or unwanted material 3 Push the tube into the John Guest fitting making sure all connections to the John Guest fittings are pushed in past the O ring to full depth at least 15mm...

Страница 18: ...e the the hoses need to hoses need to have a constant have a constant downward downward gradient to the gradient to the HydroTap to HydroTap to allow all water allow all water to drain back to drain b...

Страница 19: ...UT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT SPARKLING OUTLET CO2 IN WHITE External HOT and COLD isolation valves Not Supplied Note Note the the hoses need to hoses need to have a constant have a...

Страница 20: ...commissioning the system may be customised by selecting further options in Section G Settings within the User Guide BC Sparkling 10 30 Wed 04 Jul 2018 BC Sparkling 10 30 Wed 04 Jul 2018 A new filter c...

Страница 21: ...lected BC Sparkling 10 30 Wed 04 Jul 2018 BC Sparkling 10 30 Wed 04 Jul 2018 NOTE For any subsequent filter changes or any operational procedures please refer to the HydroTap user guide located inside...

Страница 22: ...liters 2 6 gallons of chilled water from the chilled outlet of the HydroTap equivalent to 4 complete tanks full of water 3 If water bubbles or foams repeat steps 1 and 2 above 4 Let filled tanks stand...

Страница 23: ...y backflow of gas and or water out of the internal carbonator In addition to the HydroTap s integral Backflow prevention Some authorities require additional Backflow Prevention to be installed to comp...

Страница 24: ...iver fault No chilled water Call Zip Service Hot sensor degraded Internal fault Call Zip Service Condenser overtemp Blocked air filter Remove blockage Clean filter check user guide A DC Pump is faulty...

Страница 25: ...than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements...

Страница 26: ...han or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements R...

Страница 27: ...han or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements R...

Страница 28: ...limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requirement Average Red...

Страница 29: ...ss than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requiremen...

Страница 30: ...to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Req...

Страница 31: ...o the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requi...

Страница 32: ...to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requ...

Страница 33: ...al to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction R...

Страница 34: ...the Zip Product Determination to repair or replace will be in Zip s sole discretion Repair or replacement services will be at no cost to the Zip Customer provided that a the Zip Product is installed...

Страница 35: ...icer Provider who performed the warranty service the purchase date a detailed description of the problem and the address and phone number at which the Zip Customer can be reached Zip is committed to r...

Страница 36: ...and against NSF ANSI Standard 42 and NSF ANSI Standard 53 This will deliver the required bacte riostatic effect and the reduction of aesthetic chlorine taste odor nominal particulate Class I 0 5 m to...

Отзывы: