background image

802265US v1.27 06.21 BCS, BCS100-75 Install Instructions 

Page 9 of 36

   Technical Specifications

NOTES:

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection 

before or after the system. Systems certified for cyst reduction may be used on disinfected waters that contain 

filterable cysts.

* Available in a range of premium metallic finishes. XX refers to the specific finish of the faucet.

** BCS – Classic XX, BCS – CUBE XX, BCS – ARC XX, BCS – Celsius AIO XX, BCS100/75 – Classic XX, 

BCS100/75 – CUBE XX, BCS100/75 – ARC XX and BCS100/75 – Celsius AIO XX  have been tested and 

certified by WQA against NSF/ANSI Standard 372 for low lead requirement, and against NSF/ANSI Standard 

42 and NSF/ANSI Standard 53. This will deliver the required bacteriostatic effect and the reduction of aesthetic 

chlorine, taste, odor, nominal particulate Class I (≥ 0.5 µm to < 1 µm), cyst and lead as verified and substanti

-

ated by test data. See Performance Data Sheets for specific performance claims. Certified performance claims 

are only valid when filter cartridge 1Z-LS (Culligan Part Number 01034276) is used.

*** BCS - Classic XX, BCS - ARC XX, BCS - CUBE XX, BCS - Wave XX, BCS100/75 - Classic XX, 

BCS100/75 - CUBE XX and BCS100/75 - ARC XX have been certified by IAPMO R&T against NSF/ANSI 

Standard 372 for low lead requirement, NSF/ANSI Standard 42, NSF/ANSI Standard 53, CSA B483.1, ASSE 

1023, and ASSE 1087. This will deliver the required bacteriostatic effect and the reduction of aesthetic chlo-

rine, taste, odor, nominal particulate Class I (≥ 0.5 μm to < 1 μm), cyst and lead as verified and substantiated 

by test data. See Performance Data Sheets for specific performance claims. Certified performance claims are 

only valid when filter cartridge 1Z-LS (Culligan Part Number 01034276) is used. 

**** Add an extra 5 kg (11 lb) when full of water.

Models*: 

BCS100/75 (230V) - Classic XX

 

     

BCS100/75 (230V) - CUBE XX

 

     

BCS100/75 (230V) - ARC XX

 

     

BCS100/75 (230V) - Celsius AIO XX

 

     

BCS (230V) - Classic XX

 

     

BCS (230V) - CUBE XX

 

     

BCS (230V) - ARC XX

 

     

BCS (230V) - Wave XX

 

     

BCS (230V) - Celsius AIO XX

 

     

BCS (110-120V) - Classic XX

 

     

BCS (110-120V) - CUBE XX

 

     

BCS (110-120V) - ARC XX

 

     

BCS (110-120V) - Wave XX

 

     

BCS (110-120V) - Celsius AIO XX

Model

BCS100/75 (230V)

BCS (230V)

BCS (110-120V)

Command Center dimensions, 

WxDxH, mm (in)

340 x 460 x 333

(13.5” x 18.5” x 13.0”)

340 x 460 x 333

(13.5” x 18.5” x 13.0”)

340 x 460 x 333

(13.5” x 18.5” x 13.0”)

Dry weight, kg (lb)****

24 kg (53 lb)

24 kg (53 lb)

24 kg (53 lb)

Water inlet connection

1/2” BSP

1/2” BSP

1/2” BSP

Power outlets required

1x NEMA6-15:

230V, 50/60Hz, 15A

1x NEMA6-15:

230V, 50/60Hz, 15A

1x NEMA5-15: 120V, 

50/60Hz, 15A

Power rating

9.5A (2.03kW)

at 230V, 60Hz

6.9A (1.45kW)

at 230V, 60Hz

9.9A (1.33kW) at 

110-120V, 50/60Hz

Refrigerant

R134a

R134a

R134a

***

**

Содержание HydroTap BCS Series

Страница 1: ...27 06 21 BCS BCS100 75 Install Instructions Page 1 of 36 BCS100 75 and BCS Series Zip HydroTap Installation and Operating Instructions Scan QR Code to download the latest version of this document Eng...

Страница 2: ...before installing the Command Center The installation procedure for each of the faucets is detailed in the Faucet Installation instruction book supplied with the faucet For all operational features o...

Страница 3: ...s cylinder Section 3 CO2 Cylinder 3 1 Secure the cylinder cradle 14 3 2 Connect the regulator 14 3 3 Connect the gas hose 14 3 4 Test for gas leaks 14 STEP 4 Install the Command Center Section 4 Comma...

Страница 4: ...unter cabinet supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the Command Center has been installed correctly 2 Check all plu...

Страница 5: ...water and an immersion heating element to boil the water and all utilise a CO2 gas cylinder to carbonate the chilled water Depending on the model these units will dispense boiling water factory set t...

Страница 6: ...ction Venting Sometimes steam and or condensed droplets may discharge through a vent outlet at the faucet If the faucet is not installed using the Font pedestal ensure the faucet body is located so th...

Страница 7: ...ocated near or cleaned with water jets 7 Zip HydroTaps are not to be exposed to the elements of nature 8 Due to the process of continuous improvement Zip reserves the right to change details mentioned...

Страница 8: ...ent 1x Outlet vent 9x Screws 1x Installation Instructions this book and 1x User Guide 1x CO2 gas cylinder regulator assy Major components and accessories Accessories Description Softener and head asse...

Страница 9: ...been certified by IAPMO R T against NSF ANSI Standard 372 for low lead requirement NSF ANSI Standard 42 NSF ANSI Standard 53 CSA B483 1 ASSE 1023 and ASSE 1087 This will deliver the required bacterios...

Страница 10: ...ection point and the stop cock will not be obstructed when the Command Centers are installed For the Celsius All In One an external hot and cold water supply will be required For other faucets the sys...

Страница 11: ...saw and a 12mm Drill Keyhole or Wall Board saw 2 1 Ventilation for All Models Proper air circulation must be provided for all models The system will operate correctly only if the recommended air gaps...

Страница 12: ...ing temperatures then the inlet vent and door outlet vent See item D below will need to be fitted Alternatively a fan kit may be installed using the AUX din plug of the right hand side of the applianc...

Страница 13: ...let and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cabinet space 3 Fit the inlet vent as shown and secure with 5 screws 4 Fi...

Страница 14: ...water before re applying Do not force the seal to fit Turn the regulator OFF by rotating the regulator knob all the way out in an anti clockwise direction NOTE Two plastic seals are supplied with a n...

Страница 15: ...for leaks 4 If any bubbles appear the joint will need to be resealed CO2 Regulator Leak Test Pressure regulating knob ON OFF knob Green zone Relief valve NOTE Be careful not to lose the small sealing...

Страница 16: ...etermine which bypass position you need for your product Section 4 Command Center Installation A Rotate 90 only 1 2 3 4 NOTE Before installation determine whether a water softener or an external filte...

Страница 17: ...le 2 Remove any swarf or unwanted material 3 Push the tube into the John Guest fitting making sure all connections to the John Guest fittings are pushed in past the O ring to full depth at least 15mm...

Страница 18: ...e the the hoses need to hoses need to have a constant have a constant downward downward gradient to the gradient to the HydroTap to HydroTap to allow all water allow all water to drain back to drain b...

Страница 19: ...UT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT SPARKLING OUTLET CO2 IN WHITE External HOT and COLD isolation valves Not Supplied Note Note the the hoses need to hoses need to have a constant have a...

Страница 20: ...commissioning the system may be customised by selecting further options in Section G Settings within the User Guide BC Sparkling 10 30 Wed 04 Jul 2018 BC Sparkling 10 30 Wed 04 Jul 2018 A new filter c...

Страница 21: ...lected BC Sparkling 10 30 Wed 04 Jul 2018 BC Sparkling 10 30 Wed 04 Jul 2018 NOTE For any subsequent filter changes or any operational procedures please refer to the HydroTap user guide located inside...

Страница 22: ...liters 2 6 gallons of chilled water from the chilled outlet of the HydroTap equivalent to 4 complete tanks full of water 3 If water bubbles or foams repeat steps 1 and 2 above 4 Let filled tanks stand...

Страница 23: ...y backflow of gas and or water out of the internal carbonator In addition to the HydroTap s integral Backflow prevention Some authorities require additional Backflow Prevention to be installed to comp...

Страница 24: ...iver fault No chilled water Call Zip Service Hot sensor degraded Internal fault Call Zip Service Condenser overtemp Blocked air filter Remove blockage Clean filter check user guide A DC Pump is faulty...

Страница 25: ...than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements...

Страница 26: ...han or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements R...

Страница 27: ...han or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements R...

Страница 28: ...limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requirement Average Red...

Страница 29: ...ss than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requiremen...

Страница 30: ...to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Req...

Страница 31: ...o the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requi...

Страница 32: ...to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction Requ...

Страница 33: ...al to the permissible limit for water leaving the system as specified in NSF ANSI 42 and NSF ANSI 53 Substance Average Influent Challenge Concentration Max Permissible Product Requirements Reduction R...

Страница 34: ...the Zip Product Determination to repair or replace will be in Zip s sole discretion Repair or replacement services will be at no cost to the Zip Customer provided that a the Zip Product is installed...

Страница 35: ...icer Provider who performed the warranty service the purchase date a detailed description of the problem and the address and phone number at which the Zip Customer can be reached Zip is committed to r...

Страница 36: ...and against NSF ANSI Standard 42 and NSF ANSI Standard 53 This will deliver the required bacte riostatic effect and the reduction of aesthetic chlorine taste odor nominal particulate Class I 0 5 m to...

Отзывы: