background image

Hydro Tap Installation and Operating Instructions - 89026UK - June 2009                                                Page 21 of 24

The Zip HydroTap notifies when filter replacement is due. The default setting 
is 6000 Ltrs, but this can be set in increments of 1000Ltr from 1000Ltr to 
10000Ltrs. When a filter change is due, the Change Filter light will flash white 
once a minute and remain so until reset. A filter status light is located between 
the Red and Blue Lights on the tap head assembly. 

Depending on local water quality conditions and usage, the filter may require 
changing anywhere from 1000 Ltrs to 10000 Ltrs. You may also need to 
replace the filter if you notice unpleasant odours or tastes.

Some water may drip from the filter head (socket) during replacement. Keep a 
bucket and towel handy to catch drips and mop up any spills.

To change the Filter:

1.  Scroll through the screen menu to “Filter Flush Off” this isolates the water 

supply.

2.   Open the left door or on the compact model, remove the front cover by 

unscrewing the two Phillips headed screws and lift off to expose the filter. 
Unravel the Blue filter flush line and place the open end in the bucket.

3.  Relieve system pressure via the filter flush stop cock, a quick open and 

close will do.

4.  Grasp filter cartridge and twist right to left one quarter turn until it stops.

5.  Ease cartridge downwards to detach it from the filter head (socket).

6.  Do not tilt the cartridge as dirty water may spill from it if tilted.

7.  Unpack replacement cartridge and write today’s date where shown on the 

label. 

8.  Avoid touching the filter “O” rings and filter opening as this may cause 

bacterial contamination of the cartridge.

9.  Align cartridge tabs with the slots on the under-side of the filter head.

10. Slide cartridge upward into head and rotate left to right until it stops.

11. Locate the filter flush hose situated behind the filter cartridge and run to a 

container ready for flushing. Open the flush hose tap lever. On the control 
panel press adjust 

>

, this will start the water flushing the cartridge. Allow 

at least 7.5 Ltrs of water to run through to activate the filter and then press 
adjust 

>

 to stop the flow.

12. Isolate the filter flush stop cock and re-fit behind the filter cartridge.

13. Wipe up any spills and dispose of spent filter cartridge and packaging 

thoughtfully.

14. Scroll through the menu to “Litres Filtered”, press adjust 

>

 to reset litre 

counter. Press adjust 

>

 and it asks “are you sure”. Press adjust 

>

 again 

to lock in the command. 

15. Scroll through the menu to “Filter Used (Days)”, press adjust 

>

 to reset 

the timer. Press adjust 

>

 and it asks “are you sure”. Press adjust 

>

 again 

to lock in the command. After approx 10 seconds it will default to the 
selected mode.

16. Close the door or refit the front cover to secure the appliance. 

 Replacing the Filter 

(filtered models only)

Warning:

 

If the Zip HydroTap is switched off for a long period of time    

(e.g. More than a weekend), run water through the chilled water outlet for 
at least 5 minutes before consumption.

Domestic compact filter location

HydroTap filter location

Содержание HydroTap 30009UK

Страница 1: ...ater for kitchens Installation and Operating Instructions This Installation Instruction covers the following Domestic HydroTap models Domestic models 30009UK DOMHB1 HydroTap Boiling Only Unfiltered 37...

Страница 2: ...rd supporting the appliance is adequate for the total weight of the appliance when full of water Before commissioning 1 Check the unit has been secured correctly 2 Check all plumbing fittings have bee...

Страница 3: ...ting and commissioning 10 15 Pull out Font Template pages 11 12 13 14 Step F Temp and Set Point adjustment 15 Font Installation procedure 16 Operating the Tap 17 Child safety lock 18 Setting the Energ...

Страница 4: ...ake the system through a calibration process which causes the unit to over boil for a period of 45 90 secs This is normal operation once this mode is completed the system reverts back to normal operat...

Страница 5: ...ost Protection If this appliance is located where the ambient air temperature could fall below 5 C when the heater is not in use do not turn off the appliance electrically This safeguard does not offe...

Страница 6: ...for timber bench tops not supplied Nut runner tube spanner supplied for fixing tap assembly When installing a Font unit For Font installation a 108mm diameter sheet metal or hole saw to suit surface b...

Страница 7: ...A power supply of 220 240 Volt AC for connection to the heater via a 13 amp fused spur The power outlet socket must be positioned within 1 8 metres of the under sink appliance so the plug is made acc...

Страница 8: ...dersink unit SPECIAL NOTE The HydroTap undersink units are heavy take note of the weights listed in the table on page 4 If you think you cannot lift the unit safely get help and avoid possible injury...

Страница 9: ...and trim the blue tube and connect it to the chilled water outlet located on the top rear left hand side of the undersink unit Use spring clamps provided Measure and trim the red marked tube and conn...

Страница 10: ...for a short stabilisation period Once stabilised the element will cycle On bring the water to boiling point and hold it there for a short period Calibration The unit now carries out a self calibration...

Страница 11: ...Hydro Tap Installation and Operating Instructions 89026UK June 2009 Page 11 of 24...

Страница 12: ......

Страница 13: ......

Страница 14: ...Page 14 of 24 Hydro Tap Installation and Operating Instructions 89026UK June 2009...

Страница 15: ...al not the set temperatures To revert back to the Normal Operation screen press the adjust buttons together again until screen changes Press the Menu plus button once to enter the Hot Temperature Adju...

Страница 16: ...base is flush with the bench top NOTE The fixing nut above the drain elbow can be loosened to correctly position the direction of the elbow Ensure when the re positioning is complete the nut is re ti...

Страница 17: ...of this document Child Safety Lock boiling chilled models The child safety lock can be activated to prevent boiling water flowing if the hot lever is inadvertently activated To activate first press th...

Страница 18: ...s the tap to operate in a no touch mode Water will flow from between 5 and 15 seconds This is user adjustable To reset return the handle to the Off position and repeat the step The lever has to be man...

Страница 19: ...t Press either Menu or Menu button until Litres Filtered is displayed Press Adjust once and Reset Counter will be displayed press Adjust button once and Are You Sure will be displayed Press Adjust onc...

Страница 20: ...from right to left 3 three times This operation confirms de activation 6 The LCD will show Normal Operation 7 If de activation mode is required de activate by scrolling through the menu and selecting...

Страница 21: ...ill from it if tilted 7 Unpack replacement cartridge and write today s date where shown on the label 8 Avoid touching the filter O rings and filter opening as this may cause bacterial contamination of...

Страница 22: ...rmation Check filter usage on LCD screen if filter change is displayed follow instructions on page 13 Touch Hot lever and wait for Red LED to stop flashing Wait for Red LED to stop flashing Contact lo...

Страница 23: ...e 23 of 24 Typical undersink layout Domestic Compact model 437677UK shown NOTE The pressure limiting valve supplied must be fitted between the external service valve and the appliance Domestic Compact...

Страница 24: ...water conditions or to any alteration modification or repair by any party not expressly nominated by Zip No costs are payable by the customer other than any mileage or travelling time charges incurred...

Отзывы: