Step E - Testing and commissioning
(applies to all models except HT boiling only)
Filter Flush Mode (filtered models only)
The display screen will show which model you have.
Have a bucket or similar container (not supplied) at the ready to hold a
quantity of water that is ejected while the Filter Flush Mode is in operation.
Open the filter access door on the front of the HydroTap and the filter
cartridge will be exposed (or undo 2 screws near the lower corners of the
compact model to remove the front cover ). Located to the rear RHS of the
cartridge is a fixed flush line, approx 600mm long and the flush line stop
cock. Place the free end of the flush line into the bucket or container (not
supplied).
Turn “ON” both water and electricity supplies and open the flush line stop
cock. The display will show Filter Flush Menu. To activate press adjust
>
and run at least 7.5 Ltrs of water through to activate the filter membrane.
Press the adjust
>
button again to stop the Filter Flush Mode. Turn OFF the
Filter Flush stop cock and re-locate the tube and stop cock in the filter
compartment. Turning OFF the Filter Flush Mode puts the HydroTap into
calibration mode. Press adjust
>
to start calibration. The element will now
cycle On and heat the water to 95ºC maintaining it at that temperature for a
short stabilisation period.
Once stabilised, the element will cycle On, bring the water to boiling point and
hold it there for a short period.
Calibration
The unit now carries out a self calibration function to ensure correct
temperatures are maintained. During this period the Red LED on the Tap Head
assembly flashes slowly until the calibration function is complete.
Once this step is complete (approx 5 minutes) the unit will default to normal
operation.
When starting, both Boiling and Chilled cycles activate simultaneously after
calibration has taken place, the descriptions below indicate what happens
during each cycle.
Boiling
The unit is now running in normal operating mode. The Red LED will flash
until usable temperature is reached.
Before using the HydroTap wait 5 minutes after this point to allow adequate
fill time. The unit is now ready for use. Use cable clips (not supplied) to tidy
and secure wiring.
Chilled
(excluding Domestic Compact model)
When water and power are turned On, the Blue LED flashes slowly on the Tap
Head assembly. The compressor activates and water begins to fill the chiller
tank at the prescribed rate. When the water is chilled to 10ºC the Blue LED on
the Tap Head assembly stops flashing and stays illuminated.
Continued on P. 15
Installation procedure
continued
Boiling Water Lever
Chilled Water
Red Light White Light Blue Light
Use these buttons to
scroll through the menu
Use these buttons to
activate and de-activate
the program selected
NOTE :
New hose sets supplied with the
unit should be used. Do not use
old hose sets.
Содержание HydroTap 30009UK
Страница 11: ...Hydro Tap Installation and Operating Instructions 89026UK June 2009 Page 11 of 24...
Страница 12: ......
Страница 13: ......
Страница 14: ...Page 14 of 24 Hydro Tap Installation and Operating Instructions 89026UK June 2009...