INDEX

HydroTap specifications

Installation check list ....................................................................................................................4

General product features .............................................................................................................5

Important safety instructions ........................................................................................................6

Warnings and regulatory information ...........................................................................................6

Major components and accessories .............................................................................................7 

Technical specifications ...............................................................................................................8

Before installation and site requirements .....................................................................................9

Installation instructions

Step 1 

-

 

Measure and cut all the tap holes, fit the taps : Refer to 803341UK Tap installation 

                 instructions supplied with the tap head, for tap mounting arrangements.            

Step 2 

- Check for adequate ventilation. 

           Section 1- Ventilation.

                     1.1- Ventilation for all models.............................................................................................10

Step 3 

- Install the filter & tap.

           Section 2 -  Filter system & tap installation.      

           2.1- Installing the filter system ...........................................................................................11

           2.2- Mounting the filter head .............................................................................................11

           2.3- Filter installation .........................................................................................................11

           2.4- Connecting the tap .....................................................................................................12

Step 4 

- Install the Command Centre.

           Section 3 - Command Centre installation.           

           3.1- Command Centre installation  ....................................................................................12

           3.2- HydroTap Boiling Ambient models  ............................................................................13

           3.3- HydroTap Celsius Boiling & mixer tap models ...........................................................14

Step 5

 - Commission the HydroTap.

           Section 4 - Commissioning.

           4.1- Filter flush  .................................................................................................................15

           4.2- System flush ..............................................................................................................15           

           4.3- Filter replacement ......................................................................................................15

           

          Section 5 - Tap operation.

           5.1- Arc and Cube tap operation .......................................................................................16           

           5.2- Celsius tap operation .................................................................................................18

Trouble shooting

Trouble shooting table ..................................................................................................................20

End of life disposal .......................................................................................................................21

Warranty .......................................................................................................................................22

Contact details .............................................................................................................................24

Содержание HYDROTAP 2500UK

Страница 1: ...AL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK ZIP HYDROTAP INSTALLATION INSTRUCTIONS USER MANUAL MODEL NUMBER 2500UK 2501UK Filtered boiling and ambient drinking w...

Страница 2: ...5 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK The HydroTap series offers a range of interchangeable taps to suit the customer s needs Arc range Celsius Arc range These standalone ta...

Страница 3: ...arrangements Step 2 Check for adequate ventilation Section 1 Ventilation 1 1 Ventilation for all models 10 Step 3 Install the filter tap Section 2 Filter system tap installation 2 1 Installing the fi...

Страница 4: ...o a wholesome water supply Check the Command Centre rating plate and ensure correct power is available Check the under counter cupboard floor supporting the Command Centre is adequate for its total we...

Страница 5: ...ap mounted on a sink or worktop which has been designed for residential applications The HydroTap utilises an immersion heating element to boil the water These boiling models will dispense boiling wat...

Страница 6: ...led using the font ensure the tap body is located so the tap outlet vent safely dispense into the sink bowl area Lifting Take care when lifting The Command Centre may exceed safe lifting limits If you...

Страница 7: ...water jets Do not expose the Zip HydroTap to the elements of nature Due to the process of continuous improvement Zip reserves the right to change details mentioned in this manual without notice Visit...

Страница 8: ...ered Boiling 1 8 1x13A 1 50 216 x 272 x 338 6 5 Min Max water supply pressure Arc and Cube HydroTaps 0 17 MPa 1 7 bar 0 5 MPa 5 0 bar Celsius mixer taps 0 17 MPa 1 7 bar 0 5 MPa 5 0 bar Filter 0 17 MP...

Страница 9: ...required The Command Centre must be installed in accordance with IEE regulations See Technical specification page 8 for power ratings Note Check all cable and hose lengths against inlet outlet positio...

Страница 10: ...ated in the specification sheets and installation instructions must be observed Adequate ventilation must be provided to ensure that the cupboard space temperature does not exceed 350 C 1 2 Preferred...

Страница 11: ...ter through the supply line thoroughly before connection Connect the pressure limiting valve to the isolating valve not supplied Mount the filter head and connect the stop cock in a convenient positio...

Страница 12: ...tic pipe and connect it to the ambient outlet located on the top of the Command Centre ambient models only Measure and trim the CLEAR silicone tube and connect it to the vent outlet located on the top...

Страница 13: ...ET RED CLEAR BLUE AMBIENT OUTLET BLUE Note Electrical power cable length is 3 0m Position the Command Centreaccording to the hose and cable lengths supplied Note All silicon tubes plastic pipes to the...

Страница 14: ...m 50mm 535mm Note Electrical power cable length is 3 0m Position the Command Centreaccording to the hose and cable lengths supplied Note All silicon tubes plastic pipes to the taps must be cut to size...

Страница 15: ...ck the water is clear with no soapy looking bubbles from the residue of the factory sanitisation process 4 3 Filter replacement For safe operation the filter cartridge should be replaced at least ever...

Страница 16: ...e manually returned to the OFF position When unattended the control light will automatically default to the AMBIENT blue illuminated mode after a short period To dispense boiling water Touch the selec...

Страница 17: ...mode was just disabled the safety and select lights will alternatively flash red By default the sleep mode setting is disabled Red boiling water light Continually illuminated This indicates that the b...

Страница 18: ...as shown in the adjacent diagram The integral safety lock cannot be disabled Indicator light Safety button To dispense mixed hot and cold water The mixer tap lever is operated as a conventional flick...

Страница 19: ...t Warning Lights If there is a fault with the system both the safety light and the warning light will flash for 1 2 second ON and 1 2 second OFF until the fault is rectified Call Zip on 0345 6 005 005...

Страница 20: ...Water supply not connected Check to ensure plumbing connection is made Power supply not connected Check power plug is correctly fitted and switch is turned on Water or moisture on the tap control Eli...

Страница 21: ...wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for collection...

Страница 22: ...uthorised parts or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary a...

Страница 23: ...23 INSTALLATION INSTRUCTIONS USER MANUAL 804428UK V1 03 OCT 2017 ZIP EP HYDROTAP TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK NOTES...

Страница 24: ...428UK V1 03 OCT 2017 ZIP EP HYDROTAP TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK Zip Water UK 14 Bertie Ward Way Dereham Norfolk NR19 1TE 0345 6 005 005 s...

Отзывы: