Page 11 of 16
Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00
In 2 Hour Sleep Mode, if there has been no water drawn through the tap or no touches of the capacitive switch sensors
for two hours, the temperature of the water in the tank will be allowed to drop to and be maintained at 65ºC. (The time
taken for the water temperature to drop to 65ºC can be as much as 12 hours depending on ambient conditions and other
external factors).
In 4 Hour Sleep Mode, if there has been no water drawn through the tap or no touches of the capacitive switch sensors
for four hours, the temperature of the water in the tank will be allowed to drop to and be maintained at 65ºC.
As soon as water is drawn through the tap, or there is a touch on the capacitive switch sensors, the Hydroboil Plus
returns to full power mode.
In Low Light Mode, as soon as the ambient light (in the room where the Hydroboil Plus is installed ) drops below 100lux,
the unit goes into energy saver mode and will allow the temperature of the stored water to drop to and be maintained at
65ºC. As soon as the ambient light rises above 100lux, the Hydroboil Plus returns to full power mode.
A normal office has an ambient light level of 200-300lux.
The Default configuration for the Hydroboil Plus is as follows.
tting operational modes
Default settings
TEMPERATURE SETPOINT: 98ºC
FILTER
TIMER:
OFF
SLEEP
MODE:
OFF
LOW LIGHT MODE:
OFF
SUN ON TIME 1:
--:--
SUN OFF TIME 1: --:--
SUN ON TIME 2:
--:--
SUN OFF TIME 2: --:--
MON ON TIME 1: 08:00
MON OFF TIME 1: --:--
MON ON TIME 2: --:--
MON OFF TIME 2: --:--
TUE ON TIME 1:
--:--
TUE OFF TIME 1: --:--
TUE ON TIME 2:
--:--
TUE OFF TIME 2: --:--
WED ON TIME 1: --:--
WED OFF TIME 1: --:--
WED ON TIME 2: --:--
WED OFF TIME 2: --:--
THU ON TIME 1:
--:--
THU OFF TIME 1: --:--
THU ON TIME 2:
--:--
THU OFF TIME 2: --:--
FRI ON TIME 1:
--:--
FRI OFF TIME 1:
--:--
FRI ON TIME 2:
--:--
FRI OFF TIME 2:
--:--
SAT ON TIME 1:
--:--
SAT OFF TIME 1: --:--
SAT ON TIME 2:
--:--
SAT OFF TIME 2: --:--
Setting operational modes
The Hydroboil Plus has 2 modes of operation:
1).Normal operation mode 2). Configuration mode
Note:
The BOILING WATER symbol is not displayed until the water reaches
temperature.
In Normal operation mode the LCD will display as follows:
Normal display
Normal mode