Page 10 of 16
Zip Hydroboil Plus - Installation & Operating Instructions - 86584UK - May 2012 v1.00
DESCRIPTION
The Electronic Hydroboil Plus has user interface that consists of a graphic LCD and 4 Capacitive Sensor Switches, (CSS).
The user interface gives the current status of the Hydroboil Plus and allows the user to configure it as required.
Legend:
1 = ZIP Symbol
2 = Day of the Week indicator
3 = Setpoint Value
4 = CHANGE FILTER indicator
5 = ON indicator
6 = OFF indicator
7 = Sleep Symbol
8 = Sleep mode ( Stand by ) indicator
9 = Low light Symbol
10 = 24hour Clock
11 = BOILING WATER indicator
CSS1 = Capacitive Sensor Switch 1
CSS2 = Capacitive Sensor Switch 2
CSS3 = Capacitive Sensor Switch 3
CSS4 = Capacitive Sensor Switch 4
The LCD and capacitive sensor switches connect to the Controller PCB via a 4-way serial cable.
The DIP Switches on the Controller PCB should be configured as follows.
The Electronic Hydroboil Plus has a real time clock that operates in 24 hour mode, and can have 2 ON-OFF times per
day. If the user selects either of the energy saver modes, (see below), ON-OFF mode cannot be used, (The user is not
able to access this part of the configuration). The real time clock is battery backed meaning the unit does not loose the
configuration data if power is removed.
The Hydroboil Plus has two energy saver ( stand by ) modes that can be used in an either/or configuration. The energy
saver modes differ from on/off mode in that the water in the tank is maintained at 65ºC rather than allowing it to drift
back to ambient.
1) Sleep
Mode,
and
2)
Low Light Mode. (Sleep-when-it’s-dark feature)
Sleep Mode can be set to 2 hours or 4 hours.
Sleep Mode is indicated by the Sleep symbol on the LCD.
Low Light Mode is indicated by the Low Light symbol on the LCD.
When the unit actually enters energy saver mode it is indicated by the Sleep Mode Indicator on the LCD.
Z
Z
z
SUN
MON
TUE
WED
THU
FRI
SAT
SETPOINT
CHANGE FILTER
BOILING WATER
C
ON
OFF
2
3
4
5
6
7
8
10
11
9
1
CSS1
CSS2
CSS3
CSS4
Operating Procedures
(setting the controls)
The user interface is shown below.