Zip Econoboil - Installation & Operating Instructions - 87546 - May 2012 v1.01
Page 5 of 12
c) Cold water supply with a minimum working pressure of 0.7 bar and a
maximum working pressure of 7 bar connected via an isolation valve.
d) Outlet drainage to a sink draining board or to a drip tray.
e) Access to drainage from a vent situated at the base of the heater.
If the water pressure is likely to exceed 7 bar, a 3.5 bar pressure reducing
valve must be installed in the cold water supply line.
f) In all installation instances the walls of the heater must be vertical and the
base horizontal, there can be no exceptions to this rule.
Before You Begin
Locate the paper mounting-hole template packed with the heater.
Read the installation and operating instructions completely.
Decide whether to install with concealed or exposed plumbing and/or electrical
connections. Concealed connections are preferred for superior appearance.
Step 1 – Positioning
Position the heater so the tap will drain on to a draining board or drip tray.
Position the base of the tap to be not less than 200 mm above the draining board
(height should be increased only if essential for filling larger vessels).
Provide clearance for service access of not less than 150 mm top, 65 mm left,
20 mm right.
Mark corner positions for the heater on the wall so as to position the paper
mounting-hole template.
Step 2 – Fastening
Position mounting-hole template on wall and drill holes where shown.
Drill holes for water inlet, vent outlet and wiring if rear access is intended.
Remove
cover fastening
screws from
heater and
lift
whole cover
off
heater.
Install plumbing
and wiring
and
prepare
pipe ends
and
wiring ends
as
required.
Screw heater chassis to the wall using screws or bolts suited to the walling.
Screws or bolts must be capable of supporting the heater weight when filled.
(Refer to table to the left).
Step 3 – Connecting
a) Plumbing
Installation Procedures
3 Litre model
12.5 kg
5.0 Litre model
16.5 kg
7.5 Litre model
20.5 kg
Approximate Weight When Filled
150 mm
minimum
clearance
20 mm
minimum
clearance
from right
edge to wall
200 mm
65 mm
Installation Requirements
continued