background image

Page 12 of 12 

 Zip Econoboil- Installation & Operating Instructions - 87546 - May 2012 v1.01

Certain warranties may be implied by law into your contract with Zip. The 
warranty provided below is additional to these implied warranties and nothing 
set out below shall limit your statutory rights or rights at law. 
Zip Heaters (Aust.) Pty. Ltd warrants that, should any part fail within 12 
calendar months of installation, that part will be repaired or replaced free of 
charge by Zip or its Distributor or Service Provider, except as set out below, 
provided the appliance is installed and used strictly in accordance with the 
instructions supplied, and that failure is not due to accident, misuse, abuse, 
unsuitable water conditions, or to any alteration, modification or repair by any 
party not  expressly nominated by Zip. 

No costs are payable by the customer other than any mileage or travelling-time 
charges incurred by a Zip Service Provider or the cost of removal, cartage and 
re-installation of any component of the appliance if it needs to be returned for 
repair to Zip or its Distributor. 

This warranty does not cover damage resulting from non-operation of the 
appliance, the use of non authorised parts or consequential damage to any 
other goods, furnishings or property.

No warranty applies to the life of any filtration cartridge installed with the 
appliance as cartridge life may vary according to water quality and the rate of 
water consumption.  

Zip does not exclude, restrict or modify any liability that cannot be excluded, 
restricted or modified or which cannot, except to a limited extent, be excluded, 
restricted or modified as between the owner or user and Zip under the laws 
applicable. 

Furthermore, this warranty does not displace any statutory warranty, but, 
to the extent to which Zip is entitled to do so, the liability of Zip under any 
statutory warranty will be limited at Zip’s option to the replacement of the 
appliance or supply of equivalent appliance, the payment of the cost of 
replacing the appliance or acquiring an equivalent appliance, or the payment of 
the cost of having the appliance repaired or the repair of the appliance.

Registering Your Purchase

Registering your Zip installation on the Zip website may help to establish date 
of installation should it become necessary to service the appliance under terms 
of the Zip warranty. To register your installation go to www.zipheaters.com and 
look under the heading “Warranty”.

As Zip policy is one of continuous product improvement, changes to 
specifications may be made without prior notice. Images in this booklet have 
been modified and may not be true representations of the finished goods.

Warranty Information

Head Office

Zip Heaters (UK) Ltd
14 Bertie Ward Way
Dereham
Norfolk NR19 1TE

Website:  www.zipheaters.co.uk
 [email protected]
Telephone: 0870 608 8888
Facsimile: 01362 692 448

Содержание Econoboil HS507

Страница 1: ...2 v1 01 Page 1 of 12 Installation and Operating Instructions Zip Econoboil Budget priced instant boiling water for canteens and kitchens 103592 Zip Econoboil 3 0 litre White HS503 105592 Zip Econoboil 5 0 litre White HS505 107592 Zip Econoboil 7 5 litre White HS507 ...

Страница 2: ...Page 2 of 12 Zip Econoboil Installation Operating Instructions 87546 May 2012 v1 01 This page intentionally left blank ...

Страница 3: ...s 5 Step 1 Positioning 5 Step 2 Fastening 5 Step 3 Connecting 6 a Plumbing 6 b Venting 6 c Electrical 7 Step 4 Assembling 7 Step 5 Commissioning 7 Operating Procedures 7 Tap Operation 7 Cleaning Case 8 Earthing Continuity Verification 8 Problem Solving 8 Wall Mounting Template Dimensions 9 End of Life Disposal 9 Spare Parts List 10 Exploded View Diagram 11 Warranty Information 12 ...

Страница 4: ... strong corrosive or abrasive cleaners to clean the case of the heater Frost protection If this heater is located where ambient air temperature could fall below 5ºC when the heater is not in use do not turn off the appliance electrically This safeguard does not offer the same protection to the connecting pipework and fittings The ambient temperatures this unit must operate within are 5ºC 50ºC This...

Страница 5: ...will drain on to a draining board or drip tray Position the base of the tap to be not less than 200 mm above the draining board height should be increased only if essential for filling larger vessels Provide clearance for service access of not less than 150 mm top 65 mm left 20 mm right Mark corner positions for the heater on the wall so as to position the paper mounting hole template Step 2 Faste...

Страница 6: ...sure limiting valve must be installed in the cold water supply line Zip recommends a valve rated at 3 5 bar for this application b Venting A vent at the base of the heater must be plumbed to a safe visible location as under certain conditions it may discharge cold or boiling water and or steam For exposed vent plumbing connect vent outlet from the base of heater to a 1 2 or 12 7 mm pipe which has ...

Страница 7: ...tap one full rotation until the handle is fully vertical If the tap still feels loose continue to rotate one further turn leaving the tap in a vertical position Step 5 Commissioning Check previous steps Turn water supply ON Water is now flowing into heater check connections for leaks Wait approximately 5 minutes and check outlet tap for water This is acheived by pulling the tap handle forward Powe...

Страница 8: ...al resistance does not exceed 1 ohm If required an earth continuity test can be performed by testing between the earth pin on the products lead and a exposed piece of metal on the case Operating Procedures continued Cleaning Case Do not use strong corrosive spray or abrasive cleaners Clean the case with a soft cloth or brush and mild soap and water Symptom Possible Cause Solution Fails to dispense...

Страница 9: ... Page 9 of 12 Wall Mounting Template Dimensions Wiring Diagram 3 0 L 3 0 L 3 0 L 414 3 0L End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection centre details ...

Страница 10: ...90102 CISTERN FLOAT KIT W NUT SCREW 9 90495 BANJO SCREW HYDROBOIL 2000B 10 90501 TAP TOP KIT HYDROBOIL 11 90512 ESCUTCHEON KIT EB2000B 12 90502 TAP ASSY COMPLETE 13 90081 THERMOSTAT KIT 14 90045 ELEMENT KIT 1500W 3Litre 14 90085 ELEMENT KIT 2400W 5 7 5Litre 15 90107 FILTER KIT COLD INLET BUSH 16 90175 DRAIN PLUG KIT MB HB AB EB STAINLESS STEEL CISTERN VERSION 17 90487 CISTERN LID CLAMP KIT HB AB 1...

Страница 11: ...Zip Econoboil Installation Operating Instructions 87546 May 2012 v1 01 Page 11 of 12 Exploded View Diagram ...

Страница 12: ...talled with the appliance as cartridge life may vary according to water quality and the rate of water consumption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted or modified as between the owner or user and Zip under the laws applicable Furthermore this warranty does not displace ...