Zip Command-Centre Скачать руководство пользователя страница 8

Page 8 of 20 

   804052UK - Residential chilled and sparkling installation instructions - Sept 2016 - v3.02

Major components and accessories

Accessories

Description

Font kit

Classic & Elite

or

Arc / Cube

Replacement  

internal 0.2 micron 

filter

Disabled lever kit

(Classic HydroTap

®

)

1 X

 CO

2

 gas cylinder  

Recommended  

water block

Parts supplied

Description

Tap options

1 x HydroTap

®

G4 

Classic

Elite or 

Arc / Cube

#

(inc. Tube kit)

Command-Centre

TM

 and components

Vent kit

2 x outlet vent

1 x inlet vent

1 x

Command-Centre

TM

 

with air and water 

filters

1  x  Mains  water            

connection hose

1 x User guide and 

1 x Quick start 

guide

1 x Installation 

instruction

1 x 

CO

2

 gas cylinder 

assembly

801599 - HydroTap User Guide - Nov 2013 UK - V1.05

Page 1 of 20

ZIP HydroTap

User Guide

®

Tap Operation...................(Pages 2-5)

LCD Screen & Menu .......(Pages 6-18)

Maintenance.................... (Pages 18-20)

Date of Installation.........

Affix Model Number Label 

Here

 801599

BC160/125G4

BC240/175G4

BCH160/125G4

BCH240/175G4

AV160/125G4

AN160/125G4

AV240/175G4

AN240/175G4

801600 - Zip Quick Start Guide - October 2013 - V1.06

Parts Supplied

Description

Parts Supplied

Description

1 off

Hydrotap Tap

and hoses

Duct kit

1x Air Duct

1 x Mounting 

plate

1 off

Undersink Unit 

with air and water-

filter

Vent kit

1 x Kickboard 

louvre

1 x Door vent 

louvre

1 x front vent grill

1 x Restrictaflow 

valve and Tee 

piece for Mixer 

Taps

1 off

HydroTap 

Booster heater 

and hoses

(Supplied with 

240/175 models)

1 off Mains water 

connection hose

QUICK START GUIDE

Note: This quick start guide must be read in conjunction with 

the main installation and user instructions 

• 

Before proceeding, read the installation and user instructions

• 

Check all the components are present and correct.

• 

Check that you have all the necessary tools

• 

Ensure the underbench can support the product weight when full of water,                                   

(Check the specifications in the main book and allow an extra 5-8kg when full. )

Before installing ensure the following have been provided at 

the installation site:

• 

Sufficient space in the cupboard to install all of the undersink units in accordance 

with these Installation Instructions. Refer to technical specification for dimensions. If 

required, make allowance for a booster heater. (Refer to the main book, for detailed 

installation instructions). 

• 

A potable water supply connection with isolating valve inside the cupboard within 

reach of the flexible braided hose and positioned so that the connection point and the 

stop cock will not be obstructed when all the undersink units are installed. 

• 

For Zip HydroTap 160/125 &160/175 models, a 220-240Vac, 10A GPO will be 

required. For Zip HydroTap 240/175 models, two 220-240Vac, 10A GPOs will be 

required. (One GPO is for the Zip HydroTap and the other for the Booster heater).                                                                                                                         

NOTE: Check the cable lengths and outlet positions before proceeding. 

• 

A potable cold water supply with a minimum working pressure of 172kPa and a 

maximum working pressure of 700kPa connected via an isolation valve. 

• 

For the mains pressure All-IN-ONE, both a hot and cold water supply will be required.

• 

The undersink appliances must be mounted in upright positions as shown in the 

diagrams. 

IMPORTANT!

  Do not proceed with the installation if these 

requirements are not met.

STEP 1- 

Prepare and fit the Taps

Hole positioning: 

Position the tap such that it dispenses into 

the sink bowl with ample clearance for a cup or tea pot. Alternatively, 

the tap could be mounted away from the sink using a Zip Font, avail-

able as an accessory.

Apply a light smearing of silicon sealant 

on the underside of the upper spacer to 

ensure a watertight fi t.

For HydroTap and Mixer taps 

cut a 35mm hole in the bench / sink top.

BENCH TOP

Ø35mm

HydroTap Tap

Mixer Tap 

4-in-1

 

(If required)

NUT

LOWER RUBBER 

WASHER

UPPER 

RUBBER 

WASHER

WASHER

BRAIDED 

HOSE x 3

UPPER RUB-

BER WASHER

LOWER RUB-

BER WASHER

WASHER

NUT

White Hose

Ext. Mains

Blue band

Mixer  IN

Red band

Mixer Out 

O-RING

BASE 

BLOCK  

SPIDER

BASE 

BLOCK 

NUT

USB 

CABLE

ALL 

THREAD 

ROD

NOTE: feed each of 

the tubes and elec-

trical cable evenly in 

between the legs of 

the BASE BLOCK 

SPIDER.

All-In-One Tap 

(If required)

For AIO mains and vented Taps

Cut a 50mm hole in the bench / sink top.

NOTE: make sure the tap location will allow the nozzle to drain into the sink. 

SINK TOP

50mm

ALL THREAD 

ROD

STAINLESS 

STEEL  

WASHER

SPIDER 

CLAMP

NUT

BLACK 

PLASTIC 

SPACER

NOTE: feed each of the three tubes and 

electrical cable evenly in between the legs of 

the SPIDER CLAMP when installing. 

Fit the 

STAINLESS STEEL           

WASHER, 

SPIDER CLAMP, 

AND 6mm NUT.  

6mm 

NUT

SPIDER 

CLAMP

Stainless 

washer

Black plastic 

spacer

35mm dia hole

Sink

O-RING

SINK TOP

Fit the O-ring to the underside of the AIO tap 

then pass all hoses through the 50mm hole. 

Chiller 

connection 

BLUE

From 

Mixer OUT

 to Tap - Vented version only

Boiler 

connection 

RED

Blue ring on 

RHS mains IN to

       

Mixer IN

White ring

on LHS to 

Mains in

Tap

O ring Base

Clear tube to Vent

For Accessories contact Zip:

Tel 0345 6 005 005

Website: www.zipwater.com/uk

Email: [email protected]

Содержание Command-Centre

Страница 1: ...02 Page 1 of 20 Zip HydroTap G4 Installation instructions Chilled sparkling model Command CentreTM Filtered chilled and sparkling drinking water for residential kitchens Affix model number label here...

Страница 2: ...taps to suit the customer s needs Classic HydroTap G4 range Arc Cube HydroTap G4 range Elite HydroTap G4 range These standalone taps are directly compatible with the G4 Command CentreTM Celsius HydroT...

Страница 3: ...ead Step 2 Check for adequate ventilation Section 1 Ventilation 1 1 Ventilation on all models 11 Step 3 Fit the CO2 gas cylinder Section 2 CO2 cylinder and regulator 2 1 2 4 Connect secure and test th...

Страница 4: ...er cupboard floor has sufficient strength to support the Command CentreTM when full of water see page 9 for weights Before commissioning Check the Command CentreTM has been installed correctly Check a...

Страница 5: ...r residential applications The Zip HydroTap G4 Command CentreTM utilises a conventional refrigerant compressor to chill the water and uses a CO2 gas cylinder to carbonate the chilled water The Command...

Страница 6: ...n To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Lifting Take...

Страница 7: ...nd CentreTM is rated for 230V 50Hz AC operation Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the power supply The Zip HydroTap G4 Command...

Страница 8: ...o that the connection point and the stop cock will not be obstructed when all the undersink units are installed For Zip HydroTap 160 125 160 175 models a 220 240Vac 10A GPO will be required For Zip Hy...

Страница 9: ...sparkling models 1x13A 0 35 280 x 405 x 333 30kg Min Max water supply pressure HydroTaps and Mains All in One taps 0 25 MPa 2 5 bar 0 7 MPa 7 bar Chilled and sparkling HydroTap G4 range Chilled spark...

Страница 10: ...40V AC 13A socket will be required The Command CentreTM must be installed in accordance with IEE regulations See Technical specification page 9 for power ratings Note Check all cable and hose lengths...

Страница 11: ...the cupboard position A2 Where possible air inlet vent and the air outlet vent should be positioned at opposite ends of the same cupboard space 1 1 Ventilation for all models The clearance envelope di...

Страница 12: ...upright position 2 2 Connect the regulator Remove the gas cylinder from the strap Make sure the regulator knob is turned fully clockwise to the end stop before fitting Screw the regulator clockwise o...

Страница 13: ...eak test to check for gas leaks between regulator and cylinder and between regulator and braided hose Stage 1 1 Turn the gas off 2 Using soapy water applied with a sponge or with a brush cover all of...

Страница 14: ...mand CentreTM The blue chilled and white sparkling pipes must be insulated with the sleeving provided CHILLED OUT Note Mains hose length is 750mm Electrical power cable length is 3 0m nom Position the...

Страница 15: ...lope Note Mains hose length is 750mm Electrical power cable length is 3 0m nom Position the Command CentreTM according to the hose and cable lengths supplied 3 3 Chilled sparkling and mixed hot cold C...

Страница 16: ...oning the system may be customised by selecting further options in section G Settings of the user manual Section 4 Commissioning Commissioning Press the MENU button for main menu Press the Install but...

Страница 17: ...ter Flush Menu Stop cock operation Have a bucket or similar container not supplied at the ready to hold a quantity of water that will be ejected while the filter flush mode is in operation Open the fi...

Страница 18: ...ocked Blocked air filter Remove blockage clean filter check user guide Water leak Isolate Mains Water leak Turn off mains water supply call for service Compressor Over Run Compressor too hot Check ven...

Страница 19: ...n of the appliance the use of non authorised parts or consequential damage to any other goods furnishings or property No warranty applies to the life of any filtration cartridge installed with the app...

Страница 20: ...rks of Zip Heaters Aust Pty Ltd Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US510385...

Отзывы: