ChillTap Extra - Installation & Operating Instructions -  CT2/140 - June 2013 v1.01

Technical Data / Installation requirements

Spare Parts & Accessories

•  Power supply:

 220-240V AC  50Hz for connection via a double pole switched fused spur with a minimum breaking 

capacity of 13A. The circuit should be protected by a suitably rated RCD.

•  Operating temperatures:

 5ºC -  35ºC.

Installation Requirements:

•  A potable water supply with a minimum supply pressure of 0.07 MPa - 0.7 MPa  (0.7 bar to 7 bar).

  

For best results we recommend minimum static pressure of 0.2 MPa (2 bar).

•  NOTE!

 We recommend you supply and install an isolating valve in the supply line before the connection to the product 

as an independent means of isolating the water in order to carry out maintenance or servicing.

•  Site the chiller unit into the cupboard as close to the proposed outlet tap position as is possible, to minimise the 

length of tubing exposed between the chiller unit and the tap.

•  Allow at least 50mm around the chiller unit to permit free airflow. Both the top and the front of the chiller must 

remain accessible for servicing purposes. 

Model Chilled  

Water

Ambient  

Water

Chilled Water  

glasses* per hour 

@ 5 - 10°C

Initial Draw  

Glasses*

Recovery  

Glasses*

Total rating  

Watts

Weight 

Empty 

Kg**

Weight 

Full 

Kg

Under-Sink  

W x H x D

CT1/140

ü

ü

140 

8

140

300

22.7

24.27 353 x 291 x 385

*Standard Glass = 200ml    ** Weight is chiller unit only wit no accessories

Font Kit .............................................................ZT004 
Sub Micron Filter ..............................................ZT002
Pressure Reducer set at 0.35 MPa (3.5 bar)  .....AQ3
*Water Block (Water Shut Down System) ..........HE45004

*The recommended optional Water Block is ideal for limiting potential leakage 
and resulting water damage from water chillers and their supply pipe work 
which are subject to mains water pressure.
It is easily installed via standard 3/4” BSP water connection and can be pre-set 
from 5 to 50 litres. The Water Block also incorporates a non-return valve.

HE45004

•  This appliance must not be used by any person (including children) with limited physical, sensorial or mental  

abilities or failing experience and / or knowledge unless they are supervised by a person responsible for their safety 
or received instructions about how to use the appliance.

•  Children should be supervised in order to make sure that they do not play with the appliance.
•  The appliance must only be used when correctly installed and in perfect working order.
•  This product is approved to the LVD and EMC directives and CE endorsed.
•  Zip Heaters (UK) Ltd cannot be held liable for any damages caused by failure to observe these instructions.

Please leave these instructions with the end user after installation.
To ensure you have a copy of the latest instructions please visit www.zipheaters.co.uk. 

 Caution: Refrigerant

•  The ChillTap contains R134a refrigerant under pressure. No part of the unit should be exposed to a naked flame. 
•  Maintenance of the refrigeration unit must be carried out by an accredited service provider or qualified refrigeration  

mechanic.

Safety \ Information

 Cont.

Содержание ChillTap Extra

Страница 1: ... 8 ChillTap Extra Installation Operating Instructions CT2 140 June 2013 v1 01 Zip ChillTap Extra Filtered Ambient and Chilled drinking water Affix Model Number Label Here Installation and Operating Instructions ...

Страница 2: ...witched off prior to electrical connection The appliance its wiring and piping must not be modified in any way In case of malfunction isolate the power supply immediately In case of leaks also isolate the water supply Repairs must only be carried out by Zip Heaters UK Ltd or an authorised Zip service engineer If the power supply cable is damaged it must be replaced by a Zip Service Engineer or a q...

Страница 3: ...ly wit no accessories Font Kit ZT004 Sub Micron Filter ZT002 Pressure Reducer set at 0 35 MPa 3 5 bar AQ3 Water Block Water Shut Down System HE45004 The recommended optional Water Block is ideal for limiting potential leakage and resulting water damage from water chillers and their supply pipe work which are subject to mains water pressure It is easily installed via standard 3 4 BSP water connecti...

Страница 4: ...sink oriented so both the operating levers are easily accessible Slide the rubber washer then the brass washer followed by the nut over the plastic tubes from under the sink tighten the nut to secure the tap firmly into place Install the Filtration Unit The filtration unit should be mounted as close as possible to the front of the cupboard to allow for ready and easy access during filter changes U...

Страница 5: ...careful not to nick scratch or damage it during installation Ensure there is adequate ventilation available through the cupboard If there is inadequate ventilation and the cupboard temperature rises to above 40 C the chiller may become damaged and malfunction which will void the product warranty The air temperature should be no more than 35 C There must be a minimum 168cm of cupboard cross flow ve...

Страница 6: ... filtration cartridges when required may cause the water to become biologically unsafe Make an entry in your diary to check the water quality of the ChillTap at least six months after installation and after every subsequent filter change Use only a Zip ZT002 Filter to match that used with this ChillTap Replacement filter cartridges can be obtained through plumbing suppliers or directly from Zip Re...

Страница 7: ...r Service for advice on 0845 6 005 005 Cleaning Service End of Life Disposal Never use strong corrosive or abrasive cleaning materials on the Zip ChillTap Wipe clean the outer surfaces with a sponge or a soft cloth using a mild soap and water The louvres on the sides of the chiller unit need to be kept free of dust and lint to permit free flow of air through the vents They should be checked regula...

Страница 8: ...nstalled with the appliance as cartridge life may vary according to water quality and the rate of water consumption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted or modified as between the owner or user and Zip under the laws applicable Furthermore this warranty does not displac...

Отзывы: