ChillTap Extra - Installation & Operating Instructions -  CT2/140 - June 2013 v1.01          

 

                                     Page 2 of 8

Contents

Safety \ Information

Safety Information ............................................................................................................................................. Page 2 - 3
Technical Data / Installation Requirements ...............................................................................................................Page 3
Spare Parts & Accessories .......................................................................................................................................Page 3 
Installation Instructions ...................................................................................................................................... Page 3 - 5
Commissioning ........................................................................................................................................................Page 6
Operating Procedure ................................................................................................................................................Page 6
Maintenance ............................................................................................................................................................Page  6      
Cleaning ..................................................................................................................................................................Page 7
Service ....................................................................................................................................................................Page 7
End of Life Disposal .................................................................................................................................................Page 7
Warranty Information ...............................................................................................................................................Page 8
Contact Details ........................................................................................................................................................Page 8

 

WARNING:

•  Please read all installation requirements, installation procedures and precautions before installing any Zip ChillTap.
•  Never attempt to install any Zip ChillTap without reading all of the applicable instructions.
•  Installation, commissioning and maintenance of this appliance must only be carried out by a competent installer who 

will then be responsible for adhering to all relevant standards and regulations.

•  Appliance to be wired to a double pole switched fused spur with a minimum breaking capacity of 13A. The circuit 

should be protected by a suitably rated RCD.

•  Installation must comply with current IEE regulations and any Local Authority requirements.
• 

 This appliance must be earthed.

•  Check that the power supply is switched off prior to electrical connection.
•  The appliance, its wiring and piping must not be modified in any way.
•  In case of malfunction isolate the power supply immediately. In case of leaks also isolate the water supply. Repairs 

must only be carried out by Zip Heaters (UK) Ltd or an authorised Zip service engineer.

•  If the power supply cable is damaged it must be replaced by a Zip Service Engineer or a qualified electrician.
•  The power supply cable must be adequately secured and power outlet must be in a safe and accessible position after 

installation.

•  Check that the power supply is switched off prior to electrical connection.
•  Do not remove the appliance cover under any circumstances without first isolating the appliance from the power supply.
•  This unit is designed for indoor use and must not be installed outdoors or exposed to the elements.

WARNING:

Situations that could cause injury to yourself or others.

CAUTION:

Situations that could cause damage to your appliance or other equipment.

NOTE:

Notes, usage tips or additional information.

IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. 

NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT 

CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO 

SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. 

 

RETAIN THESE INSTRUCTIONS FOR FUTURE USE.

Содержание ChillTap Extra

Страница 1: ... 8 ChillTap Extra Installation Operating Instructions CT2 140 June 2013 v1 01 Zip ChillTap Extra Filtered Ambient and Chilled drinking water Affix Model Number Label Here Installation and Operating Instructions ...

Страница 2: ...witched off prior to electrical connection The appliance its wiring and piping must not be modified in any way In case of malfunction isolate the power supply immediately In case of leaks also isolate the water supply Repairs must only be carried out by Zip Heaters UK Ltd or an authorised Zip service engineer If the power supply cable is damaged it must be replaced by a Zip Service Engineer or a q...

Страница 3: ...ly wit no accessories Font Kit ZT004 Sub Micron Filter ZT002 Pressure Reducer set at 0 35 MPa 3 5 bar AQ3 Water Block Water Shut Down System HE45004 The recommended optional Water Block is ideal for limiting potential leakage and resulting water damage from water chillers and their supply pipe work which are subject to mains water pressure It is easily installed via standard 3 4 BSP water connecti...

Страница 4: ...sink oriented so both the operating levers are easily accessible Slide the rubber washer then the brass washer followed by the nut over the plastic tubes from under the sink tighten the nut to secure the tap firmly into place Install the Filtration Unit The filtration unit should be mounted as close as possible to the front of the cupboard to allow for ready and easy access during filter changes U...

Страница 5: ...careful not to nick scratch or damage it during installation Ensure there is adequate ventilation available through the cupboard If there is inadequate ventilation and the cupboard temperature rises to above 40 C the chiller may become damaged and malfunction which will void the product warranty The air temperature should be no more than 35 C There must be a minimum 168cm of cupboard cross flow ve...

Страница 6: ... filtration cartridges when required may cause the water to become biologically unsafe Make an entry in your diary to check the water quality of the ChillTap at least six months after installation and after every subsequent filter change Use only a Zip ZT002 Filter to match that used with this ChillTap Replacement filter cartridges can be obtained through plumbing suppliers or directly from Zip Re...

Страница 7: ...r Service for advice on 0845 6 005 005 Cleaning Service End of Life Disposal Never use strong corrosive or abrasive cleaning materials on the Zip ChillTap Wipe clean the outer surfaces with a sponge or a soft cloth using a mild soap and water The louvres on the sides of the chiller unit need to be kept free of dust and lint to permit free flow of air through the vents They should be checked regula...

Страница 8: ...nstalled with the appliance as cartridge life may vary according to water quality and the rate of water consumption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted or modified as between the owner or user and Zip under the laws applicable Furthermore this warranty does not displac...

Отзывы: