Operation

Commissioning

Operating the Tap

Chilled water is dispensed (within the rated capacity) by rotating the spring 
loaded lever. In the upright position the tap is off. When the lever is rotated 
forward water will flow until the lever is released. When released, the lever will 
spring back to the upright (off) position.

Purge the air from the unit when the plumbing connections are complete by turning ‘ON’ the water supply and operating 
the tap until the water flows through without spluttering. 

Check for leaks. Repair any found.

Installation instructions 

continued

Plumbing. 

NOTE

 If the mains water pressure is greater than 0.7 MPa (7 bar) a pressure reducer will be required. AQ3 is available 

as an option (see options table page 5).

Connect a cold water supply to the 1/2” BSP female inlet at the back of the chiller where shown in the diagram.

Connect a drain to the 40 mm PVC female outlet at the back.

Alternatively, there are pre-punched holes in the base of the Chillmaster for bottom access to plumbing services.

This appliance incorporates backflow protection. No further backflow protection is required for connection to the water 
supply. 

Electrical

Electrical connection is to be made by a Zip Service Engineer or a qualified electrician.  
Installation must comply with current IEE regulations and any Local Authority requirements. 

Appliance to be wired to a double pole switched fused spur with a minimum breaking capacity of 13 amps. The supply 
flex should be minimum 3 core 0.75mm

2

 and securely fixed to the clamp provided within the unit behind the front cover.

       

This appliance must be earthed.

DO NOT

 turn the electric supply ‘ON’ until the unit is purged.

If not yet installed, fit the filter change reminder light batteries to the circuit board matching the polarity. The batteries are 
located on the inside of the front cover. To remove, undo the the two security fittings at the base of the cover with the 
supplied key.

ROTATE

FORWARD

Operating the Bubbler

Chilled water is obtained momentarily by 
pressing the bubbler button. Water will stop 
flowing once the button is released. 

The water is chilled by a refrigeration unit 
fitted within the cabinet stand, under the 
basin.

PRESS

Содержание CH101

Страница 1: ...85UK Zip Chillmaster Installation operating instructions Mar 2016 v1 05 Installation and operating instructions Zip Chillmaster Floor Mounted Chiller CH101 Floor mounted chiller Affix model number lab...

Страница 2: ...information Page 3 Technical data Page 4 Spare parts and accessories Page 5 Installation instructions Page 6 Commissioning Page 7 Operation Page 7 Maintenance Page 8 Filter replacement Page 8 Cleaning...

Страница 3: ...r a qualified electrician The cross sectional area of the power supply cable must be appropriate for the power rating and location of the appliance The power supply cable must be adequately secured Ch...

Страница 4: ...17 MPa 1 7 bar Power Supply 1 N PE 240 V Power Rating 300 W Rated Current 1 5 A Chiller type Fan cooled condenser with a compressor rated at 200 W Stainless steel water bowl and outer case Storage ca...

Страница 5: ...ter Block 2 The Optional ZG500 Installation Kit allows the Zip Chillmaster to be installed fully in accordance with the requirements of BREEAM Health Wellbeing Credit HEA 16 Drinking Water by enabling...

Страница 6: ...on a level floor and screw the feet in or out as appropriate to make the unit level and steady Leave at least a 50 mm gap between the sides of the unit and any walls to allow air flow through the vent...

Страница 7: ...the base of the Chillmaster for bottom access to plumbing services This appliance incorporates backflow protection No further backflow protection is required for connection to the water supply Electri...

Страница 8: ...r periods of non use longer than 12 hours Not changing the filter cartridges when required may cause the water to become biologically unsafe Use only a Zip filter to match the one used in your system...

Страница 9: ...e personnel Before calling for service check that both the water and electricity supplies are turned ON and functional Call an electrician a plumber or Zip customer service for assistance service spar...

Страница 10: ...s to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling of unwanted electrical and ele...

Страница 11: ...returned for repair to Zip or its Distributor This warranty does not cover damage resulting from non operation of the appliance or consequential damage to any other goods furnishings or property No wa...

Страница 12: ...ation operating instructions Mar 2016 v1 05 Page 12 of 12 Contact Details Zip Water UK 14 Bertie Ward Way Dereham Norfolk NR19 1TE Telephone 0845 6005 005 Mobile 0345 6005 005 Web www zipwater com uk...

Отзывы: