Trouble shooting

System fault          

message

Possible cause

Solutions

Power Board Fault

Electrical disruption

Check power supply and all fuses

Interface Fault

Internal fault

Call Zip Service

Level Board Fault

Internal fault

Call Zip Service

Condenser Screen Blocked Blocked Air filter

Remove blockage / Clean filter / check user guide

Water leak, Isolate Mains Water leak

Turn off mains water supply / Call for service

Compressor Over Run

Compressor too Hot

Check ventilation

Water Supply Failure

No water

Check water supply is turned ON

Hot Sensor Open

Internal fault

Call Zip Service

Hot Sensor Closed

Internal fault

Call Zip Service

Cold Sensor Open

Internal fault

Call Zip Service

Cold Sensor Closed

Internal fault

Call Zip Service

Flood Sensor Open

Internal fault

Call Zip Service

Condenser Sensor Closed Internal fault

Check Ventilation / Call Zip Service

Condenser Sensor Open

Internal fault

Check ventilation / Call Zip service

Heater Fuse / Driver Fault Internal fault

Call Zip Service

Heater Driver Fault

No hot water 

Call Zip Service

Compressor. Driver Fault No chilled water

Call Zip Service

Hot Sensor Degraded

Internal fault

Call Zip Service

A DC pump is faulty

Internal fault

Call Zip Service

Condenser Overtemp.

Blocked air filter

Remove blockage / Clean filter / check user guide

Steam too Cool

Internal fault

Call Zip Service

Steam Sensor Open

Internal fault

Call Zip Service

Steam Sensor Closed

Internal fault

Call Zip Service

Over Steamed

Internal fault

Call Zip Service

Hot Tank Overfilled

Internal fault

Call Zip Service

Comp Fuse / Driver Fault Internal fault

Call Zip Service

Hot tank under filled

Low water pressure

Check water supply

Boil dry protection

Safety activated

Turn OFF / On power to reset

Flash Mem corrupted

Internal fault

Call Zip Service

Flow Sensor Fault

Internal fault

Call Zip Service

Call an electrician, a plumber, or Zip on 0845 6 005 005 or 0345 6 005 005 for assistance, service, spare parts 

or enquiries.

Содержание Celsius HydroTap G4 range

Страница 1: ...HydroTap G4 Celsius Installation instructions Filtered boiling chilled and chilled sparkling drinking water with unfiltered mixed hot and cold water for residential kitchens Affix model number label h...

Страница 2: ...rs a complete range of features and functionality to suit the customer s needs Celsius Arc range Celsius Cube range Boiling mixed hot cold These taps are directly compatible with the G4 residential Co...

Страница 3: ...ation Section 2 Ventilation 2 1 Ventilation on all models 14 Step 3 Mount the external filter softener if required 3 1 Mounting the filter head and cartridge installation 15 3 2 Cartridge installation...

Страница 4: ...under counter cupboard supporting the Command CentreTM is adequate for the total weight of Command CentreTM when full of water Before commissioning Check the Command CentreTM has been installed correc...

Страница 5: ...to chill the water for chilled models and an immersion heating element to boil the water for boiling models Chilled sparkling models utilise a CO2 gas cylinder to carbonate the chilled water Boiling...

Страница 6: ...the font pedestal ensure the tap body is located so the tap outlet safely dispenses into the sink bowl area Lifting Take care when lifting the Command CentreTM which may exceed safe lifting limits If...

Страница 7: ...s of nature Due to the process of continuous improvement Zip reserves the right to change details mentioned in this manual without notice Visit www zipwater com uk to ensure you have the latest copy C...

Страница 8: ...on with isolating valve inside the cupboard within reach of the flexible braided hose and positioned so that the connection point and the stop cock will not be obstructed when all the undersink units...

Страница 9: ...will continue to be dispensed after the rated capacity has been used although this may affect the dispense temperature Min Max water supply pressure Celsius Boiling mixed hot cold 0 17 MPa 1 7 bar 0...

Страница 10: ...ecification page 9 for power ratings Note Check all cable and hose lengths against inlet outlet positions before proceeding See section 5 for general layout A potable water supply connection with isol...

Страница 11: ...nut runner not supplied for fixing the tap assembly Hole size and positioning Position the tap such that it dispenses into the sink bowl with ample clearance for a jug cup or tea pot 35mm hole require...

Страница 12: ...ation will allow the tap spout to drain into the sink 35mm Fit the brass and rubber washers and secure with brass nut Installation instructions 35mm hole 1 2 Chilled and sparkling mixed hot cold tap i...

Страница 13: ...d hot cold tap installation Nut Brass washer Lower rubber washer Upper rubber washer USB lead Chilled blue or Boiling red pipe depending on model Vent clear pipe Mains hot and cold braided hoses Vent...

Страница 14: ...drawn in from the bottom of the cupboard and expelled through the top of the cupboard The outlet vent A should be towards the top of the door position A1 or side of the cupboard position A2 Where pos...

Страница 15: ...a quarter turn anticlockwise until cartridge comes to a complete stop Cartridge installation is complete Note The following instructions to flush the filter must be undertaken AFTER commissioning of...

Страница 16: ...O2 may be discharged from the connection to the regulator as the cylinder and the regulator are be assembled together Any CO2 released will be cold Screw on the regulator to stop this leakage Note The...

Страница 17: ...lied with a sponge or with a brush cover all of the gas joints with a liberal amount of suds Stage 2 1 Turn the gas ON 2 Adjust the pressure to between 2 7 3 0 bar 3 Inspect the joint for leaks 4 If a...

Страница 18: ...ion B if a scale filter is fitted before flushing the scale filter as described on page 22 5 2 Braided hose fitting Install the mains water braided hoses to the Command CentreTM before locating in pla...

Страница 19: ...G OUT BYPASS IN VENT BYPASS OUT 280mm 50mm 50mm 535mm COLD isolation valve not supplied Clearance Envelope Note All plastic pipes silicon tubes must be trimmed to size They must have a constant fall t...

Страница 20: ...lves not supplied 280mm 50mm 50mm 535mm Male to male adaptor to T piece supplied T piece supplied Clearance Envelope Note All plastic pipes silicon tubes must be trimmed to size They must have a const...

Страница 21: ...lope Note Mains hose length is 750mm Electrical power cable length is 3 0m nom Position the Command CentreTM according to the hose and cable lengths supplied 5 3 Chilled sparkling and mixed hot cold A...

Страница 22: ...he filter flush mode is in operation Open the filter access door on the front of the HydroTap G4 Celsius and the filter cartridge will be exposed Located to the rear right hand side of the cartridge i...

Страница 23: ...ished close the stop cock then press STOP to end filter flush mode Press NEXT for the boiling calibration screen boiling models OPEN Position CLOSED Position ON OFF Filter flush menu Stop cock operati...

Страница 24: ...ck Ventilation Call Zip Service Condenser Sensor Open Internal fault Check ventilation Call Zip service Heater Fuse Driver Fault Internal fault Call Zip Service Heater Driver Fault No hot water Call Z...

Страница 25: ...o be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for collection and recycling of unwanted electrical and electronic...

Страница 26: ...or This warranty does not cover damage resulting from non operation of the appliance the use of non authorised parts or consequential damage to any other goods furnishings or property No warranty appl...

Страница 27: ...802149UK Celsius residential Installation instructions Jan 2016 v2 03 Page 27 of 28 Notes...

Страница 28: ...Aust Pty Ltd Zip products described in this publication are manufactured under one or more of the following patents AU675601 AU637412 AU635979 GB0422305 GB2065848 US4354049 US5103859 US5099825 and SA2...

Отзывы: