802149UK Celsius residential - Installation instructions -Jan 2016 v2.03
Section 2
Ventilation
2.1 Ventilation for all models
• The clearance envelope dimensions stated in the specification sheets and installation instructions must
be observed.
• Adequate ventilation must be provided to ensure that the cupboard space temperature does not exceed
35
0
C.
Preferred arrangement
• 4mm door buffers (at the four corners of each door) supplied with the Command-Centre
TM
should be used
to provide adequate ventilation in normal usage, see diagram below left.
Note
The vent kit has to be installed in a way that allows
air to be drawn in from the bottom of the cupboard and
expelled through the top of the cupboard. The outlet vent
A
should be towards the top of the door (position
A1
) or side
of the cupboard (position
A2
). (Where possible air inlet vent
and the air outlet vent should be positioned at opposite ends
of the same
cupboard
space).
Vent cut-out details
*
A
Air outlet vent
B Air inlet vent
Alternative arrangement
For chilled sparkling models in high use applications where
the cupboard space temperature is near 35
0
C or higher, the
vent kit (supplied with chilled and chilled sparkling models)
can be used to provide further ventilation by convection.
* For dual
exhaust
fan cut-out
dimensions
see the
instructions
provided with
the kit.
Door buffers
A1
A2
B
Note
Flat outlet vent shown in adjacent diagram, louvred
vent also supplied with CS models.