background image

3

Installation instructions & user manual

 

T210023 v1.02 NOV 2018 - ZIP AP430S-AP4100S

Technical support 

 

Tel: 0345 6 005 005 email: service@zipindustries .co.uk  www.zipwater.co.uk

•  These instructions will guide you through the installation, maintenance and use of the Zip 

Aquapoint, however, if you require any further information please call Zip customer service 

on 0345 6 005 005.

•  The Zip Aquapoint is an unvented water heater designed for connection directly to 

incoming mains water supply and can serve one or more outlets using conventional 

taps.

•  Care should be taken that the unit being chosen can meet the demands of the outlets 

being supplied.

•  The casing is constructed of powder coated steel and heat losses are minimised by the 

high efficiency polyurethane foam insulation.

•  The inner vessel is constructed from glass enamelled steel sheet and pressure tested to 

1.2 MPa (12 bar).

•  A manually resettable safety cut out automatically cuts off the electrical supply to the 

heating element in the event of a malfunction.

• 

A sacrificial magnesium anode is fitted to the vessel to provide anti-corrosion protection for 

the vessel and the heating element.

•  Gradual erosion of the anode will occur depending on local conditions and in extreme 

cases, conditions may cause rapid erosion resulting in particles being deposited as a 

residue or emitted from the heater.

•  The Aquapoint should not therefore, be used in applications where the quality of the water 

is paramount. Regular preventative maintenance inspections are vital to achieve optimum 

performance and durability of the Aquapoint.

•  The condition of the anode should be checked regularly by an authorised Zip service 

provider as part of the preventative maintenance programme.

•  If the hot water system is not used for two weeks or more, it is recommended that a hot 

tap be turned on for several minutes at a sink, basin or bath, it is not recommended that 

either a dishwasher, clothes washer or other appliance be used before the heater is 

returned to service. 

•  The Aquapoint must be installed in accordance with these instructions and all current 

legislation, codes of practice and regulations governing the installation of unvented hot 

water cylinders in force at the time of installation.

•  Please contact Zip Customer Service for advice on 0345 6 005 005.

 

Approvals

 

•  Aquapoint complies with LVD and EMC directives and is CE endorsed.

General product description

Содержание Aquapoint AP430S SmartEco

Страница 1: ...0023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk Zip Aquapoint Installation instructions user manual Modelnumber AP430S...

Страница 2: ...nstruction manual please visit www zipwater co uk to download the latest copy Please leave these instructions with the end user after installation General Product Description 3 Approvals 3 Technical D...

Страница 3: ...ection for the vessel and the heating element Gradual erosion of the anode will occur depending on local conditions and in extreme cases conditions may cause rapid erosion resulting in particles being...

Страница 4: ...564 49 740 Weekly electricity consumption without smart control kWh 16 215 28 501 30 049 57 832 Thermostat temperature setting eco Smart value 1 Storage volume V l 29 1 49 1 78 8 98 1 Mixed water at 4...

Страница 5: ...ating suitable for the nomi nal current of the Aquapoint The cross sectional area of the connection cable must be appropriate for the power rating and location of the Aquapoint The connecting cable mu...

Страница 6: ...unvented systems Temperatures in excess of approximately 43 C are perceived as hot especially by children and may cause a feeling of burning Please consider using the temperature controls This Aquapo...

Страница 7: ...vertically on the wall can be drained through the heater s inlet pipe For this purpose it is advisable to install a T piece with an outlet valve between the inlet pipe and safety valve Please do not...

Страница 8: ...ement 2000W 002 AQ0331 Gasket 005 94807 Bimetal safety cut out 006 AQ0320 Sacrifying anode 30 l 006 AQ0306 Sacrifying anode 50 l 006 AQ0307 Sacrifying anode 80 l 100 l 013 AQ0338 Fixing flange 019 950...

Страница 9: ...rced where the Aquapoint will be installed The AP4 model may only be mounted vertically To facilitate future service interventions you are advised to install the heater in accordance with the installa...

Страница 10: ...m Fig 4 pressurised mix taps should be used at the outlet points To ensure safe operation of the heater a safety valve should be installed on the inlet pipe to prevent elevation of pressure for more t...

Страница 11: ...th the capacity of at least 5 of the heater volume To ensure proper operation of the safety valve periodical inspections must be carried out to remove limescale and make sure the safety valve is not b...

Страница 12: ...xpansion vessel with wall bracket from cold inlet set take off 4 Hot water outlet 5 Temperature control 6 Neon indicator 7 Tundish to drain 8 Temperature and pressure relief valve 9 Expansion relief v...

Страница 13: ...hrough a double pole isolating switch with at least 3mm contact separation in each pole and with a minimum rating of 13A All internal wiring is factory mounted and should not be altered or modified A...

Страница 14: ...email service zipindustries co uk www zipwater co uk Electrical wiring diagram 1 2 4 5 3 N L 230V AC REF DESCRIPTION 1 Connection terminal 2 Thermal cut out 3 Electronic regulator 4 Electrical heating...

Страница 15: ...Safety device e g temperature relief valve Tundish Metal Discharge Pipe D2 From Tundish with Continuous Fall Metal Discharge Pipe D1 From Temperature Relief Valve to Tundish with Continuous Fall Disch...

Страница 16: ...hich you can reduce the use of electric energy Fig 8 Control panel Display of Set temperature Actual temperature of water in the heater Errors On Off button temperature setting Indication of the SMART...

Страница 17: ...to start recording During the recording time the electronic regulator remembers your habits and takes them into account while heating the water after the recording period has ended The recording takes...

Страница 18: ...ssary clean the limescale that accumulates depending on the quality quantity and temperature of the water inside the heater The service provider will also recommend the date for the next inspection de...

Страница 19: ...nded to open the warm water tap on the mixing tap and let the water run for at least two minutes through the outlet pipe the water stream should be steady medium strength about as thick as a pencil Er...

Страница 20: ...icates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling o...

Страница 21: ...Provider or the cost of removal cartage and re installation of any component of the Aquapoint if it needs to be returned for repair to Zip or its Distributor This warranty does not cover damage result...

Страница 22: ...22 Installation instructions user manual T210023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk Notes...

Страница 23: ...23 Installation instructions user manual T210023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk Notes...

Страница 24: ...T210023 v1 02 NOV 2018 ZIP AP430S AP4100S Technical support Tel 0345 6 005 005 email service zipindustries co uk www zipwater co uk ZipWaterUK 14BertieWardWay Dereham Norfolk NR191TE 03456005005sales...

Отзывы: