19
Installation instructions & user manual
T210023 v1.02 NOV 2018 - ZIP AP430S-AP4100S
Technical support
Tel: 0345 6 005 005 email: service@zipindustries .co.uk www.zipwater.co.uk
• Before draining, please disconnect the Aquapoint from the power supply, open the warm
water handle on the mixing tap and drain the warm water.
•
When the water in the Aquapoint is cooled, close the flow of cold water into the heater and
unscrew the flexible pipe on the warm water outlet.
• The Aquapoint can now be drained through the outlet valve on the inlet pipe.
• After draining the water through the inlet pipe, a small quantity of water remains in the
heater.
•
When refilling the heater with water it is recommended to open the warm water tap on the
mixing tap and let the water run for at least two minutes through the outlet pipe (the water
stream should be steady, medium strength, about as thick as a pencil).
Error functions
In case of error, control lights start to flash on the display
Error
Description
Indicator
Solution
E1
Temperature
sensor error
Repeated 2x quick pulse
of the control light on the
display
Call service (heater out of order).
E5
Overheating
Repeated 3x quick pulse
of the control light on the
display
The error is automatically deleted when
the temperature drops below the set
value. Should the error repeat, please
call the service company.
E44
Dry start
Repeated 4x quick pulse
of the control light on the
display
Fill the heater with water. The error is
deleted by switching off the heater or
by holding button for 3 seconds.
Troubleshooting
Service & maintenance
1
1
1
1
2