![Zip 82232 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/zip/82232/82232_installation-and-operating-instructions-manual_3796408002.webp)
Page 2 of 8
Zip Filter Tap - Installation & Operating Instructions - 82232 - January 2012 v1.01
#
Read these Warnings First
# Installation
Instructions
Install the Filtration Unit
The filtration unit (A) should be mounted
as close as possible to the front of the
cupboard, to allow for ready and easy
access during filter changes.
1. Usually the side of the cupboard, near
the door, is most suitable.
2. Using the two screws provided,
screw the filter head to the inside of the
cupboard, allowing 260 mm miniumum
between the underside of the filtration
head and any obstructions like shelves,
etc.
3. Write the installation date on the
filter cartridge. Fit the cartridge into
the housing. The model you have
may appear slightly different to that
illustrated, however, operation and function is identical.
4. Align the tabs of the cartridge with the filter housing and insert it into the socket. Turn the cartridge a quarter turn to
the right until it stops and locks into position.
5. Check that the direction of flow on the filter head is correct.
Install the Filter Tap
1. Position the filter tap at the back of the sink where there is a 45 mm wide flat area within the draining areas of the
sink. The recommended position is over one corner of the bowl. Make sure the selected position allows the spout to
overhang the sink bowl.
The cutout size is 25 mm. Mark the centre of the new Filter Tap position on the sink with a centre punch.
Please read all installation requirements, installation procedures and precautions before installing any Zip FilterTap.
Never attempt to install any Zip FilterTap without reading all of the applicable instructions.
The outlet from any Zip Filter must be connected directly to an outlet spout on the sink and must not be obstructed by a
tap or valve or in any other way.
These appliances ares not intended for use by persons (Including Children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use
of the appliances by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliances
The units are for indoor use only and must not be exposed to the elements of nature.
These units must not be positioned in an area that may be cleaned by a water jet and must not be cleaned by a water jet.
All plumbing connections must be made in accordance with AS/NZS3500.
Before installing, ensure there is cold water supply with a minimum working pressure of 50 kPa and a maximum working
pressure of 600 kPa. (A 600 kPa limiting pressure valve is supplied)
A