26
Quick Start Installation Guide
807118 v1.06 10.22 G5 BC Quick Start Guide
Quick Start Installation Guide
807118 v1.06 10.22 G5 BC Quick Start Guide
27
12.6 System priming
SECTION 12: Commissioning
• Read the on screen information.
• Touch the run arrow to go to the next
screen.
SYSTEM PRIMING
12:12 PM
The system reticulation will be primed
with mains water.
Ambient water will automatically be
dispensed from the tap.
SYSTEM PRIMING
12:12 PM
Hot Tank
Pause:
Cold Tank
Completed
Cold tank
emptying.
[Normal operation]
Auto
Dispense
• Monitor the on screen information.
• Note
if ‘Font’ has been selected on the drain away option (see section
12.4) and auto dispense is disabled on entry into this screen; the screen
prompts the user to dispense using the tap during the process.
12.7 Cleaning preparation
HYDROTAP CLEAN PREPARATION
12:12 PM
Step 1.
Insert cloth below filter.
Step 2.
Remove filter and refit dust cap.
• Read the on screen information.
• Place a cloth under the filter.
• Remove the filter, refit the dust cap,
and set aside in a clean environment.
SECTION 12: Commissioning
• Check the adapter seal
is present and correctly
positioned in the adapter.
• Install the HydroTap Clean
adapter (1) into the filter
head.
• Turn the adapter a quarter
turn to the right until it
comes to a stop and locks.
HYDROTAP CLEAN PREPARATION
12:12 PM
Step 3.
Install HydroTap Clean adapter (1) into filter head.
Step 4.
Insert HydroTap Clean can (2) into adapter (1).
Filter head
HydroTap Clean
adapter (1)
• Remove the lid from the HydroTap
Clean can (2).
HydroTap Clean
Gently cleans for pure tasting water
ORGANIC AND pH-NEUTRAL
HydroTap Clean
can (2)