background image

26

Quick Start Installation Guide

 

807118 v1.06 10.22 G5 BC Quick Start Guide

Quick Start Installation Guide

 

807118 v1.06 10.22 G5 BC Quick Start Guide

27

12.6 System priming

SECTION 12: Commissioning

•  Read the on screen information.
•  Touch the run arrow to go to the next 

screen.

SYSTEM PRIMING

12:12  PM

The system reticulation will be primed 

with mains water.

Ambient water will automatically be 

dispensed from the tap.

SYSTEM PRIMING

12:12  PM

Hot Tank

Pause:

 

Cold Tank

Completed

Cold tank 

emptying.

[Normal operation]

Auto 

Dispense

 

•  Monitor the on screen information. 

•  Note

 if ‘Font’ has been selected on the drain away option (see section 

12.4) and auto dispense is disabled on entry into this screen;  the screen 
prompts the user to dispense using the tap during the process.

12.7 Cleaning preparation

HYDROTAP CLEAN PREPARATION

12:12  PM

Step 1.

 

Insert cloth below filter. 

Step 2.

 

Remove filter and refit dust cap.

•  Read the on screen information.

•  Place a cloth under the filter.
•  Remove the filter, refit the dust cap, 

and set aside in a clean environment.

SECTION 12: Commissioning

•  Check the adapter seal 

is present and correctly 
positioned in the adapter.

•  Install the HydroTap Clean 

adapter (1) into the filter 
head.

•  Turn the adapter a quarter 

turn to the right until it 
comes to a stop and locks.

HYDROTAP CLEAN PREPARATION

12:12  PM

Step 3.

 

Install HydroTap Clean adapter (1) into filter head.

Step 4.

 

 Insert HydroTap Clean can (2) into adapter (1). 

Filter head

HydroTap Clean  

adapter (1)

•  Remove the lid from the HydroTap 

Clean can (2). 

HydroTap Clean

Gently cleans for pure tasting water

ORGANIC AND pH-NEUTRAL

HydroTap Clean  

can (2)

Содержание Zip HydroTap G5

Страница 1: ...tion Guide 807118 v1 06 10 22 G5 BC Quick Start Guide 1 Zip HydroTap G5 Quick Start Installation Guide Command Centre Boiling Chilled models AFFIX PRODUCT LABEL HERE Visit our website to download the...

Страница 2: ...ECTION 9 Fit the Booster 17 SECTION 10 Connect the Booster 18 SECTION 11 Connect the Command Centre 19 SECTION 12 Commissioning 22 Contact details 36 SECTION 1 Using these instructions This document i...

Страница 3: ...ls all refrigeration must comply with AS NZS 60335 2 24 In the UK the system must be installed in accordance with water supply byelaws current IEEE regulations and local authority byelaws SECTION 2 IM...

Страница 4: ...the elements of nature The booster complies with protection class IP 20 For UK a pressure limiting valve must be fitted for mains water For continued safety of this appliance it must be installed ope...

Страница 5: ...me 72 hours or more do not fill and commission the HydroTap until ready for first use For water taste and quality reasons following any non use period of more than 72 hours Zip recommends to perform a...

Страница 6: ...200 2 0 700 7 0 200 2 0 500 5 0 Limescale filter 200 2 0 700 7 0 200 2 0 500 5 0 Specification Rating Power 230V 50 60Hz 2 20kW Power 240V 50 60Hz 2 40kW Flow rate 1 2 L min SECTION 5 Parts supplied P...

Страница 7: ...al kit parts Use of tools can be hazardous Assess the risks before you start SECTION 6 Set up the ventilation BC100 BC40 models Vent tray The vent tray must be fitted It provides a safe exhaust for re...

Страница 8: ...door or floor cut out Warm air is exhausted through upper gap provided by the door buffers 4mm door buffers supplied Inlet vent Air inlet Air outlet SECTION 7 Connect the water supply Note correct str...

Страница 9: ...out Bypass in see pages 20 21 Insert Remove Insert Remove For filter head and scale filter installation use the guide supplied with the filter head and filter respectively Bypass valve Rear of the Com...

Страница 10: ...Connect the Command Centre For HydroTap mixer tap and any optional accessories use instructions supplied with individual kit components Connections key HydroTap Braided hose Command Centre USB Tap Ge...

Страница 11: ...LING OUTLET CO2 IN USB BCS comm BCS res BC comm CHILLED OUTLET MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT C...

Страница 12: ...ack arrow to go back to previous menu 12 2 Select the language 12 1 Turn on the supplies familiarise yourself with the system Connect the mains electrical power cable to the supply Turn the power and...

Страница 13: ...ntainer if the HydroTap is mounted such that the waste water dispenses into a sink or container Note This selection will determine if water is dispensed automatically or requires operation of the tap...

Страница 14: ...en prompts the user to dispense using the tap during the process 12 7 Cleaning preparation HYDROTAP CLEAN PREPARATION 12 12 PM Step 1 Insert cloth below filter Step 2 Remove filter and refit dust cap...

Страница 15: ...se the performance of the boiling unit and perform chilled cleaning Info CAUTION Steam may vent from the tap spout Avoid touching the spout during this process Chlorinated water will be dispensed from...

Страница 16: ...Ensure cloth is below HydroTap Clean can 2 Remove can 2 from HydroTap Clean adapter 1 Unscrew the HydroTap Clean can 2 Ensure to hold the adapter in place while unscrewing the can HydroTap Clean Gentl...

Страница 17: ...ectly from the touch screen display dispensing boiling water text flashes on the screen while holding the button After the boiling tank is emptied the system progresses to the tank flush screen If NO...

Страница 18: ...LING CHILLED CHANGE FILTER SAFETY Light intensity varies from site to site therefore it is recommended that a re calibration be performed at the time of the installation All direct sunlight must be sh...

Страница 19: ...ation and maintenance ZipWater ABN46000578727 67 77AllinghamStreet CondellParkNSW2200 Postal LockedBag80 Bankstown1885 Australia Tel 612 97963100 Freecall1800947827 1800ZIPTAP As Zip policy is one of...

Отзывы: