UNItivity 5000
Initial System Setup
User Manual
Copyright © 2022 Zinwave. All rights reserved.
10-8
data immediately prior to the
“Download System Log” button being clicked. System Logs may be sent
to Zinwave to facilitate diagnosis of system issues. System Logging is disabled by default and should
be enabled only where a problem is suspected.
Ensure that the System Log is downloaded within 15 minutes of the occurrence of the issue that
is to be investigated by Zinwave.
Event Log filtering can be enabled to avoid some repetitive warnings/alarms filling up the Event Log.
For example, by
customizing the Service Warning Alarm Relay to ‘ignore’ Uplink AGC service warnings
on the RUs, and then enabling Event Log filtering, it is possible to eliminate unwanted AGC warnings
from the Event Log.
10.6 Hub Setup
On this GUI screen, the user can Restart the Primary Hub, set the IP network settings, configure the
SNMP Traps, choose between a secure (https) or insecure (http:) connection, set the Date & Time and
configure the User Security Settings.
10.6.1
Restart Hub
Click the 'Restart Hub' button to reboot the Primary Hub.
10.6.2
IP Settings
IP Address
The address of the Hub on the network. Ensure that it does not clash with an existing device on the network.
Subnet Mask
This defines how IP addresses are partitioned on your network.
Gateway Address
The address of a router on your network that provides access to other networks and/or the internet. If you do not
have such a device set this field to 0.0.0.0.
10.6.3
SNMP Settings
Trap IP Address
The network address to which traps are to be sent. This would usually be the network management computer.
Setting this field to 0.0.0.0 disables traps.
Trap Port
The UDP port number to which traps are sent. For most systems this will be 162.
Trap Type
SNMP traps can be configured to use either the “Trap” or “Inform” transport mechanism. “Trap” is more widely