background image

 

 

www.zinexts.com                             20                     MagPurix 12 EVO Instruction Manual 

5.

  6.

 

7.

 

2.5 Extraction 

(1) Plastic consumable set up:   

 

 

 

 

Insert the cartridges

 

Push down each cartridges 
(ST cartridges with “click”

 

sound)

 

Insert Reaction Chambers 
(push down each wells)

 

Insert Tip Holder

 

 

Содержание MagPurix 12 EVO

Страница 1: ...rification System 12 EVO Catalog No ZP01018 Rev Date Sep 07 2022 Manual No IFU MP01 01018 Version 3 3 Instruction Manual Obelis s a Bd Général Wahis 53 1030 Brussels Belgium Tel 32 2 732 59 54 Fax 32 2 732 60 03 mail obelis net ...

Страница 2: ...gent Kits 9 1 3 Operating Environment Condition 9 1 4 Unpack the MagPurix 12 EVO system 11 1 5 Overall View 12 2 0 Getting Started 13 2 1 Turning ON the power 14 2 2 Touch Panel and User Interface 18 2 3 Preparation 18 Function Test 19 2 5 Extraction 20 3 0 Cleaning Maintaining the MagPurix 12 EVO 25 4 0 Troubleshooting 29 5 0 Specifications 31 6 0 Warranty 32 7 0 Revision history 32 ...

Страница 3: ...ins important information regarding the safe use of the MagPurix 12 EVO Please read this manual carefully before you start to run the system for the first time especially for Safety Information If there is any question about how to install or operate the system please contact our certified distributors agents or email our technical support center support zinexts com Manufacturer Info Manufacturer ...

Страница 4: ...ructions or procedures may lead to physical injury or even death or could cause damage to the instrument Important Important points an important note for appropriate usage as well as prohibited actions Note Note indicates the procedures that should be obeyed and supplementary information for use HOT SURFACE This symbol labels potentially hot surfaces on the instrument IVD This symbol shows this in...

Страница 5: ... power cable For maintenance disconnect the power plug from the outlet Do not touch the power plug when you hear the crash of thunder Do not pour any liquid on the MagPurix 12 EVO system Do not place any objects containing liquid on the MagPurix 12 EVO system Doing so may cause device failure fire or electric shock If the device starts to smoke or smells strange immediately unplug the power cable ...

Страница 6: ...ent is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired About Reagent Kits CAUTION When handling any of the kits refer to the respective handbook Reagents in each kit should be handled by observing the safety information and precautions regarding the kit Extraction should be performed in an appropriate laboratory or workplace Note The kits...

Страница 7: ...on sterilization and or disinfection When you use a third party company to dispose of wastes outsource this work to an operator licensed to handle medical waste subject to special control and give them the medical waste manifest at the same time Zinexts Service Center For technical problem and instrument maintenance http tw dictionary yahoo com dictionary p maintainceplease contact our service cen...

Страница 8: ...on other devices Caution TURN OFF POWER BEFORE INSERT AND PICK UP SD CARD To insert the Un locked SD card in right direction Please make sure all the components are free from damages as soon as you get the system If any damage is found please contact your local representative for instant support Note Zinexts global warranty does not cover damages from transportation or improper operation A MagPuri...

Страница 9: ... tip F Sample tube G Elution tube Note Reagent kits are to be purchased separately Please contact your local agents or representatives to get further info The contents of reagent kits will vary Refer to the handbook of kits enclosed in reagent box for details 1 3 Operating Environment Condition Use the MagPurix 12 EVO system in a location that meets the following conditions ...

Страница 10: ...ht Block the sunlight by closing curtains or blinds as necessary A location which is well ventilated and not dusty A location where the temperature does not go up and down suddenly Warming a cold room suddenly or moving the MagPurix 12 EVO system from a room with low temperature to a warm room may cause condensation inside the device resulting in abnormal extraction A location where the temperatur...

Страница 11: ...MagPurix 12 EVO system under direct sunlight or close to a heating device It may shorten the life of the MagPurix 12 EVO system or cause troubles Do not open the maintenance door while performing the experiment Do not open the front door while performing the experiment Operating Conditions 1 4 Unpack the MagPurix 12 EVO system Open the packing box and take out the instrument and related accessorie...

Страница 12: ...12 EVO system movement handling will lead to instrument damages For correct and safe use of the MagPurix 12 EVO install the device in a location close to the electrical outlet and that has enough space for installation and main switch operation 1 5 Overall View Front view with Door closed Main power switch Power Outlet Scanner Port Engineer Port Smart view window Door Handle 7 Touch Panel Bottom l...

Страница 13: ...VO Instruction Manual Front view with Door opened Inside view UV Lamp Camera R d Operation Area There is a total of 12 strips from left to right Piston Reagent kit holder Heating module Tip holder plate M module Holder lid Sample rack ...

Страница 14: ...paration to extraction completion be careful not to expose the samples to foreign contaminants such as sweat saliva etc 2 1 Turning ON the power Follow the steps below to release the fixed part inside the instrument i Plugin the power cord to the instrument and connect to the electric outlet ii Connect the barcode reader to instrument Turn the power ON and log in with User ID Display will delay st...

Страница 15: ...alization and device will release transportation fixing parts automatically Dashcam time adjustment Dashcam time adjustment is suggested for the first use Fallow the steps below to set the dashcam time Step 1 remove the dashcam as below Step 2 turn on instrument and find System from Settings ...

Страница 16: ...p 4 find each button from left side of camera and follow below steps Step 5 the dashcam will automatically start recording after turn off sensor Press OK button to pause Step 6 long press M button access to menu Step 7 press M button again to move to the next page Step 8 select Date Time and press OK ...

Страница 17: ...n Manual Step 9 use the button to adjust time to the current time and press OK Step 10 after adjustment press M button to return to the main screen Step 11 back to panel and click camera to open sensor And then hang camera back follow the same way ...

Страница 18: ... lock access to user to certain Admin options v Once logged in you will able to set up at least 10 other users with their own password Important Keep the shipping box and fixing block materials They will be needed again when transporting the MagPurix 12 EVO system 2 2 Touch Panel and User Interface 2 3 Preparation The following preparations are required for extraction operation Function Bar Homepa...

Страница 19: ...unction Test Enter the settings menu and check the position of each axis Y Z P M 1 Press button first then axis will go back to home position 2 Press button then system will going to check the position automatically Please refer to System Status for the operate information 1 2 3 4 Gloves Mask Safety Goggles MagPurix Kit ...

Страница 20: ...Purix 12 EVO Instruction Manual 5 6 7 2 5 Extraction 1 Plastic consumable set up Insert the cartridges Push down each cartridges ST cartridges with click sound Insert Reaction Chambers push down each wells Insert Tip Holder ...

Страница 21: ...ck the barcode label Note How to pull apart reagent cartridges strips Slash open the dotted line with a cutter The position of piercing pins on the right and filter tips on the left The 2nd row in the middle should be EMPTY Insert Sample Tube Insert Elution Tube Load the sample s On Sample Rack On Sample Rack To Sample Tube ...

Страница 22: ...artridges respecting the numbers order from left to right Make sure that Cartridges are inserted into the Cartridge Tray tightly You can load 1 12 strips on the tray depending on the number of samples you intend to process 2 Start Program Please refer to System Status for operating information Select the desired targets from homepage Select the Protocol then Press NEXT ...

Страница 23: ... EVO Instruction Manual Select Sample and Elution Volume then Press NEXT Select the Sample number then Press NEXT Edit the Sample ID then Press NEXT Edit the Elution ID then Press NEXT Scan Reagent Cartridge Barcode then Press NEXT ...

Страница 24: ... details Make sure the Sample Tray is placed correctly in the instrument Store the purified nucleic acids at 4 for short term storage or store at 70 for long term storage 2 6 System fixing before transportation 1 Enter to settings and select Fixing Please refer to System Status for operating information 2 Put back the Fixing block at the Position of cartridge holder System display a consumable Che...

Страница 25: ... M motor To elevate M motor before cleaning of rubbish tray and M motor 1 Enter to setting and select Function Test 2 Select CLEAN to elevate M motor 3 Cleaning of rubbish tray and M motor with mild detergent and rinse with deionized water Allow the parts to dry before use Clean and disinfect the platform surface by wiping with deionized water followed by 75 ethanol 4 To down M motor by click FINS...

Страница 26: ...x 12 EVO Instruction Manual 3 2 Cleaning of Piston 1 Enter to setting and select System 2 Clean piston Red Square by kimwipes with select Piston 75 ETOH and change new piston if there is 1 significant impurity stain salt crystal ...

Страница 27: ...ne Cleaning of sample Tray M module piston and holder lid by 75 EtOH Cleaning of heating module and using cotton swab to check buffer residue in hold of heating module User Bi weekly Check SD Memory space Cleaning of instrument body outside Cleaning of instrument body inside User Two times a year or Annually Preventive Grease ball screws if required Check motor movement Check the air tight status ...

Страница 28: ...use Clean and disinfect the platform surface by wiping with deionized water followed by 75 ethanol Clean the instrument body by removing dust gently with a dry soft cloth If the outside of the MagPurix 12 EVO system is heavily soiled or if any sample that may cause infection are adhering to the outside of the MagPurix 12 EVO system wipe with a soft paper tissue soaked with 75 ethanol ...

Страница 29: ...nstructions shown in this manual Note you cannot resume the protocol after stopping it you may lose your samples Problem with motion sensors Turn off the power and remove all samples and plastic wares Contact your local representatives Bubbles form during extraction Miss adding sample or sample volume is lower than the recommended volume Be sure to add the sample to tubes prior starting the protoc...

Страница 30: ... cartridge To collect any bead solution from the foil tap the cartridge to deposit the bead solution at the bottom of the well Clogged Tips resulting in DNA loss Ensure that the lysate does not contain any particulate material that can clog the tip sprout If needed centrifuge the sample prior to the MagPurix purification No DNA recovered Magnetic beads stored or handled improperly Store cartridge ...

Страница 31: ...xtractor Sample Processing 1 to 12 samples per batch Sample Volume Handling 100 2000 µL Processing Time See purification kit manual for details Heat Block Temperature 60 C to 70 C assuming the room temperature of 25 C Protocol Input Touch Panel UV Light 30 minutes 250 nm Built in Features 7 Touch Panel Instrument Dimensions 62 3 cm W x 63 5 cm D x 60 9 cm H Weight 70 kg Input Power AC 100 240 V 10...

Страница 32: ...es not cover any problem that is caused by i Conditions malfunctions or damage not resulting from defects in material or workmanship ii Any consumption spare parts including fuses light bulbs UV lights LED lighting sets 2 For further information about the Warranty Policy and Extended Warranty offers please contact your local representative agent or visit our website www zinexts com ...

Страница 33: ... address to Xizhi 3 0 2022 05 10 Change warranty policy 3 1 2022 07 04 Add dashcam time adjustment 3 2 2022 08 18 Change SD card capacity 3 3 2022 09 07 Change manual number Zinexts Life Science Corporation www zinexts com 16F No 93 Sec 1 Xintai 5th Rd Xizhi Dist New Taipei City 221416 Taiwan R O C Tel 886 2 2246 3579 Fax 886 2 2243 8570 Mail info zinexts com ...

Отзывы: