background image

4.

Con necting the MX82 to the track or a power bus

The ac ces sory de coder MX82 is con nected with the 

red and black wire

 to

the track or the power bus com ing from the com mand sta tions track out put.
Po lar ity is ir rel e vant. Any num ber of ac ces sory de cod ers may be con nected 
in par al lel since their own power con sump tion is ex tremely low. 

NOTE: Con necting the ac ces sory de coder to the track is only prac ti cal if the track sec tion con -
cerned is con nected it self di rectly to the com mand sta tion or booster. 

An ac ces sory de coder must not be con nected to a sec tion of track that is con nected to a track sec tion
mod ule with oc cu pancy de tec tion be cause the small cur rent con sump tion will cause the track sec tion
mod ule to in di cate an oc cu pied track that in re al ity is not true. 

5.

Con necting the MX82 to accessories

DOU BLE COIL SWITCH MA CHINES AND SIG NALS:

Such ac ces so ries are con nected with

 3 wires.

The blue wire sup plies the power and is con nected 
to the com mon wire of the turn out and the grey and
or ange wires are con nected to the sin gle wires.

MO TOR IZED SWITCH MA CHINES AND SIG NALS: 

Such units are con nected with 

2 wires.

 

The blue

wire is not needed in this ap pli ca tion. The other
wires (grey/or ange) are con nected with the switch
ma chine. The power-on time has to be pro -
grammed with CV #515, 516, 517 de pend ing on
the sub ad dress used. 

EPL SWITCH MACHINES (LGB):

EPL switch ma chines are elec tri cally iden ti cal to the
mo tor ized switch ma chine (see above). The de fault
power on time of .2 sec onds can be left as is since the
ac tual switch time of the EPL ma chine is rather short. 

SIG NALS:

Com mer cially avail able sig nals have a com mon wire
that con nect to the blue wire (pos i tive) of the de coder.
The sin gle wires are con nected with the or ange and
grey wire.

Pay at ten tion to po lar ity in case of LED’s  (only sig nals
with com mon an ode) and use an ap pro pri ate re sis tor
(usu ally 1Kohm).

                                         

 

 Page  8   

                                                      ACCESSORY DECODER MX82

                  SIGNAL

  Red bulb        green bulb

grey
orange
blue

+

TWIN COIL SWITCH MACHINE

    left coil               right coil

grey
orange
blue

      

MOTORIZED OR EPL SWITCH

MACHINE

M

grey
orange

COMMAND  

  STATION

      MX1

  

 

MX82

MX82

MX82

black,

red 

blue

grey

orange

black

red

Common positive for accessories

with 3 wires

Right turnout connection

Left turnout connection

Track

Track

MX82 Top View

Содержание MX82E

Страница 1: ...ioned in this manual Such missing or incomplete functions can be installed later by updating the software or replacing the EPROM only at the factory Beginning in October 2004 all decoders MX82 with SW...

Страница 2: ...ng with production date September October 2004 Zimo decoders are equipped to handle a software update by the end user That requires a Zimo MXDECUP decoder update module available in November 2004 as w...

Страница 3: ...s but also a sub address 2 sub addresses for the MX82V The address is required for decoder access with a cab and the sub address determines with which function key the turnout will be operated Althoug...

Страница 4: ...Identifies the decoder as accessory decoder 546 resp 34 Light uptime only when continuous on is selected as in CV 515 516 517or518 0 0 255 10 For prototypical signal operation Time in 1 10 of a second...

Страница 5: ...ed according to CV 557 556 resp 44 Motor deceleration with pulse width modula tion only if CV 515 516 517 or 518 0 0 255 0 Slow deceleration of motor drive time in 1 10ofasecond max 25sec untilthemoto...

Страница 6: ...coderhas its own CV for power on time e g one uses 515 thenext 516 and so on andthere is no chance that another decoder gets re programmed unintentionally If 2 motorized switch machines are used with...

Страница 7: ...sly with solenoid or motorized turnouts or signals or exclusively Attention The 4 servo connections are set to the next higher address by default through the CV settings 553 110 and 554 132 the servos...

Страница 8: ...o the single wires MOTORIZED SWITCH MACHINES AND SIGNALS Such units are connected with 2 wires The blue wire is not needed in this application The other wires grey orange are connected with the switch...

Страница 9: ...eets the natural requirements of many such machines For example an old fashioned non electronic model railroadpower packmaybe used But pay attentionthatonlytheDCoutput is suitable Under no circumstanc...

Страница 10: ...Turnouts 1 4 at the LENZ cab MX82 address 1 Sub address 0 3 Turnouts 5 8 at the LENZ cab MX82 address 2 Sub address 0 3 Turnouts 9 12 at the LENZ cab Address 3 DEFAULT Sub address 0 3 and so on If for...

Отзывы: