www.zi
mm
er-instruments.com
7
|
16
Enter New / Change End value of the Output 1, first digit entered,
Enter New / Change End value of the Output 1, second digit entered,
New / Change End value of the Output 1
Pressing the “
Down” key will scroll the value of the
first digit from 0 through to 2, the value will wrap from 2
round to 0.
Pressing the “
Up” key will advance the operation to
the next digit and set the first digit, in this case to “1”.
prompting for second digit.
(*Denotes that digit will be flashing).
Pressing the “
Down” key will scroll the value of the
second digit from 0 through to 9, the value will wrap from
9 round to 0, if first digit is set to 1.
Pressing the “
Up” key will advance the operation to the
next digit and set the second digit, in this case to “8”.
prompting for third digit.
(*Denotes that digit will be flashing).
Pressing the “
Down” key will scroll the value of the
third digit from 0 through to 9, the value will wrap from 9
round to 0.
Pressing the “
Up” key will advance the operation to
the next digit and set the third digit, in this case to “0”.
Enter New / Change End value of the Output 1, third digit entered,
prompting for fourth digit. (* denotes that digit will be
flashing).
Pressing the “
Down” key will scroll the value of the
fourth digit from 0 through to 9, the value will wrap from
9 round to 0.
Pressing the “
Up” key will advance the operation to the
“New / Changed End value of the Output 1” and set the fourth digit,
in this case to “0”.
(*Denotes that digit will be flashing).
New/changed End value of the Output 1 confirmed.
Pressing the “
Down” key will re-enter to the
“New / Change End value of the Output 1 edit” mode.
Pressing the “
Up” key will confirm New End value of the Output 1
and advance to the Start value of Output 1(section 3.1.6.1.2).
The End value of Current Output can be set up to 20mA.
Pressing “
Up” key will confirm the present value as
End value of the Output 1 and advance to the Start value
of Output 1(section 3.1.6.1.2).
Pressing the “
Down” key will enter the “New/Change
End value of the Output 1 edit” mode.
3.1.6.1 Output 1 parameter selection
3.1.6 Output parameter selection
3.1.6.1.1 End value of output 1
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
*
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
*
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
*
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
*
This screen allows the user to set the End value of Output 1
(,considerd as DC Current).
New / Change
value of the Output 1
Start
Pressing the “
Down” key will not affect the first digit
It always remains 0.
Pressing the “
Up” key will advance the operation to
the next digit and set the first digit, in this case to “0”.
Enter New / Change
value of the Output 1, second digit entered,
Start
prompting for second digit.
(*Denotes that digit will be flashing).
Pressing the “
Down” key will scroll the value of the
second digit from 0 through to 4, the value will wrap from
4 round to 0 depending on the set End value of Output.
Pressing the “
Up” key will advance the operation to the
next digit and set the second digit, in this case to “0”.
prompting for third digit.
(*Denotes that digit will be flashing).
Pressing the “
Down” key will scroll the value of the
third digit from 0 through to 9, the value will wrap from 9
round to 0 depending on the set End value of Output.
Pressing the “
Up” key will advance the operation to
the next digit and set the third digit, in this case to “0”.
Enter New / Change
value of the Output 1, third digit entered, prompting
Start
for fourth digit. (* denotes that digit will be
flashing).
Pressing the “
Down” key will scroll the value of the
fourth digit from 0 through to 9, the value will wrap from
9 round to 0 depending on the set End value of Output.
Pressing the “
Up” key will advance the operation to
the “New / Changed
value of the Output 1” and set the fourth digit,
Start
in this case to “0”.
(*Denotes that digit will be flashing).
New/changed
value of the
confirmed.
Start
Output 1
Pressing the “
Down” key will re-enter to the
“New / Change
value of the Output 1”.
Start
Pressing the “
Up” key will confirm New
value of the Output 1
Start
and advance to the selection of Elbow value of Output(section 3.1.6.1.3)
This screen allows the user to set the
value of Output 1
Start
(,considerd as DC Current).
Pressing “
Up” key will confirm the present value as
Start
value of the Output 1 and advance to the selection of
Elbow value of Output(section 3.1.6.1.3) or Output 2 parameter
selection(section 3.1.6.2)
Pressing the “
Down” key will enter the “
New/Change
Start
value of the Output 1 edit” mode.
3.1.6.1.2 Start value of output 1
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
*
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
*
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
*
ON O/P1 O/P2
COM
Zi
mm
er
PRO
-V
O/P 1
A
*
Start value of Output can be set up to 20% of set End value of Output.
or Output 2 parameter selection(section 3.1.6.2)
Enter New / Change
value of the Output 1, first digit entered,
Start
Содержание PRO -V
Страница 16: ...www zimmer instruments com 16 16 NOTES ...