2

|

16

Password Incorrect.

the Password entered.

Pressing the "

Down" key will re-enter to

the “Enter Password” entry stage.

Pressing the “

Up” key will exit the

setup menu.

New / Change Password

Pressing the “

Down” key will scroll the value of the

first digit from 0 through to 9, the value will wrap from 9

round to 0.

Pressing the “

Up” key will advance the operation to

the next digit and set the first digit, in this case to “4”

Enter New / Change Password, first digit entered, prompting for

second digit.

(*Denotes that digit will be flashing).

Pressing the “

Down” key will scroll the value of the

second digit from 0 through to 9, the value will wrap from

9 round to 0.

Pressing the “

Up” key will advance the operation to the

next digit and set the second digit, in this case to “1”

Enter New / Change Password, second digit entered, prompting for

third digit.

(*Denotes that digit will be flashing).

Pressing the “

Down” key will scroll the value of the

third digit from 0 through to 9, the value will wrap from 9

round to 0.

Pressing the “

Up” key will advance the operation to

the next digit and set the third digit, in this case to “4”

Enter New / Change Password, third digit entered, prompting

for fourth digit. (* denotes that digit will be

flashing).

Pressing the “

Down” key will scroll the value of the

fourth digit from 0 through to 9, the value will wrap from

9 round to 0.

Pressing the “

Up” key will advance the operation to

the “New Password Confirmed” and set the fourth digit,

in this case to “1”.

(*Denotes that digit will be flashing).

New/changed Password confirmed.

Pressing the “

Down” key will re-enter to the

“New/Change Password” entry stage.

Pressing the “

Up” key will confirm New Password

selection(section3.1.2).

ON   O/P1  O/P2

COM

Zimmer

 

PRO

 

-V

ON   O/P1  O/P2

COM

Zimmer

 

PRO

 

-V

*

ON   O/P1  O/P2

COM

Zimmer 

PRO

 

-V

*

ON   O/P1  O/P2

COM

Zimmer 

PRO

 

-V

*

ON   O/P1  O/P2

COM

Zimmer 

PRO

 

-V

*

ON   O/P1  O/P2

COM

Zimmer

 

PRO

 

-V

3.1.1.2 New/ChangePassword

Pressing the “

Down” key will scroll the value of the second digit

Pressing the “

Down” key will scroll the value of the fourth digit

Pressing the “

Down” key will scroll the value of the third digit

Pressing the “

Down” key will scroll the value of the first digit

3. Programming

Enter Password, prompt for first digit.

(*Denotes that digit will be flashing).

from 0 through to 9, the value will wrap from 9 round to 0.

In the special case where the Password is “0000” pressing

the “

Up” key when prompted for the first digit will

advance to the “Password Set/Confirmed” screen.

Enter Password, first digit entered, prompt for second digit.
(*Denotes that digit will be flashing).

from 0 through to 9, the value will wrap from 9 round to 0.

Enter Password, third digit entered, prompt for fourth digit.

Transformer parameter selection(section 3.1.2).

from 0 through to 9, the value will wrap from 9 round to 0.

Pressing the “

Up” key will advance the operation to

Enter Password, second digit entered, prompt for third digit.

(*Denotes that digit will be flashing).

from 0 through to 9, the value will wrap from 9 round to 0.

Pressing the “

Up” key will advance the operation to the

the “Password Set/Confirmed” and set the fourth digit.

Pressing “

Down” key will enter to the “New /

change Password” entry stage.(section 3.1.1.2)

Pressing the “

Up” key will advance to the Potential

ON   O/P1  O/P2

COM

Zi

mm

er

 

PRO

 

-V

*

ON   O/P1  O/P2

COM

Zi

mme

r

 

PRO

 

-V

*

ON   O/P1  O/P2

COM

Zi

mm

er

 

PRO

 

-V

*

ON   O/P1  O/P2

COM

Zi

mm

er

 

PRO

 

-V

*

ON   O/P1  O/P2

COM

Zi

mm

er

 

PRO

 

-V

the next digit and set the first digit.

Pressing the “

Up” key will advance the operation to the

next digit and set the second digit.

next digit and set the third digit.

Password Set/Confirmed.

3.1  Programming via Front LCD & Two keys

The following sections comprise step by step procedures for configuring the
Zi

mme

r

 

PRO

 

-

 

V

 

for individual user requirements.

To access the set-up screens press and hold the

 

 

Down”

 

and

 

 

Up”

keys simultaneously for 5 seconds.

 

This will take the User into the Password

 

Protection Entry Stage .

3.1.1. Password Protection

3.1.1.1 Password Verification

Password protection can be enabled to prevent unauthorised access to set-up
screens, by default password protection is not enabled.

Password protection is enabled by selecting a four digit number other than 0000,
setting a password of 0000 disables the password protection.

Programming of transducer can be done in three ways :

1) Programming Via Front LCD & two keys.

2) Programming Via optional RS485(MODBUS) communication port.

Pressing the “

Up” key will advance the operation to

(*Denotes that digit will be flashing).

This screen is displayed when the unit has not accepted

and advance to the Potential Transformer parameter

Содержание PRO -V

Страница 1: ...nnection Diagrams RS 485 ModBus 4 15030988_Rev A 10 11 3 1 1 1 Password verification 3 1 2 Potential Transformer parameter selection 3 1 2 2 Potential Transformer secondary value 3 1 2 1 Potential Transformer primary value 3 1 4 Output Type selection 3 1 4 1 Output 1 Type selection 3 1 4 2 Output 2 Type selection 3 1 5 Input parameter selection 3 1 5 1 End value of input 3 1 5 2 Start value of inp...

Страница 2: ...ssword prompt for first digit Denotes that digit will be flashing from 0 through to 9 the value will wrap from 9 round to 0 In the special case where the Password is 0000 pressing the Up key when prompted for the first digit will advance to the Password Set Confirmed screen Enter Password first digit entered prompt for second digit Denotes that digit will be flashing from 0 through to 9 the value ...

Страница 3: ... COM Zimmer PRO V INPUT x012 O P 12 y012 A A ON O P1 O P2 COM Zimmer PRO V INPUT x012 O P 12 y012 A A ON O P1 O P2 COM Zimmer PRO V INPUT x012 O P 12 y012 A A Enter New Change PT Primary value first digit entered Denotes that digit will be flashing Pressing the Down key will scroll the value of the second digit from 0 through to 9 the value will wrap from 9 round to 0 Pressing the Up key will adva...

Страница 4: ...ows the user to set RS485 parameter for instruments The range of allowable address is 1 to 247 3 1 3 Communication Parameter Selection Pressing Down key will advance to the New Change address value edit mode Pressing the Up key will confirm the present value as Address and advance to Baud Rate selection section3 1 3 2 ON O P1 O P2 COM Zimmer PRO V ON O P1 O P2 COM Zimmer PRO V ON O P1 O P2 COM Zim...

Страница 5: ...essing the Down key will scroll the value of the second digit from 0 through to 9 the value will wrap from 9 round to 0 Pressing the Up key will advance the operation to the next digit and set the second digit in this case to 5 Denotes that digit will be flashing Enter New Change End value of Input second digit entered prompting for third digit Denotes that digit will be flashing Pressing the Down...

Страница 6: ...pting New Change Elbow value of the Input Pressing the Down key will scroll the value of the second digit from 0 through to 7 the value will wrap from 7 round to 0 depending on set value of End value of Input Pressing the Up key will advance the operation to the next digit and set the first digit in this case to 4 third digit Denotes that digit will be flashing Pressing the Down key will scroll th...

Страница 7: ...set the End value of Output 1 considerd as DC Current New Change value of the Output 1 Start Pressing the Down key will not affect the first digit It always remains 0 Pressing the Up key will advance the operation to the next digit and set the first digit in this case to 0 Enter New Change value of the Output 1 second digit entered Start prompting for second digit Denotes that digit will be flashi...

Страница 8: ...2 1 End value of output 2 Enter New Change End value of the Output 2 second digit entered Enter New Change End value of the Output 2 first digit entered ON O P1 O P2 COM Zimmer PRO V O P 2 ON O P1 O P2 COM Zimmer PRO V O P 2 ON O P1 O P2 COM Zimmer PRO V O P 2 ON O P1 O P2 COM Zimmer PRO V O P 2 ON O P1 O P2 COM Zimmer PRO V O P 2 ON O P1 O P2 COM Zimmer PRO V O P 2 The End value of Voltage Output...

Страница 9: ...of the first digit from 0 through to 1 the value will wrap from 1 round to 0 depending the set End value of Output Pressing the Up key will advance the operation to the next digit and set the first digit in this case to 0 prompting for second digit Denotes that digit will be flashing Pressing the Down key will scroll the value of the second digit from 0 through to 9 the value will wrap from 9 roun...

Страница 10: ...move the Back cover of transducer by using screw driver Insert screw driver in a snap fitting slot and press in direction of arrow remove all snap fitting pillars of back cover NOTE Black portion in above diagram indicate switch position 1234 ON 1234 ON load independent current load independent voltage DIP switches T ype of output signal Type of Output Signal DIP Switch Setting Insert screw driver...

Страница 11: ...5 ModBus Zimmer PRO V supports MODBUS RS485 RTU protocol 2 wire Connection should be made using twisted pair shielded cable All A and B connections are daisy chained together The screens should also be connected to the Gnd terminal To avoid the possibility of loop currents an Earth connection should be made at one point on the network Loop ring topology does not require any termination load Line t...

Страница 12: ...o set the Analog O P Type 1 as Voltage Current Voltage 1 Current 2 40029 Sim_Output B 40035 Analog O P Type 2 This address is used to set the Analog O P Type 2 as Voltage Current Voltage 1 Current 2 Example Writing Device address Device address Start address 0E Hex Number of registers 02 Query Change Device address to 2 Byte Count Total number of data bytes received Data register 1 High Byte Most ...

Страница 13: ...in the limits of the chosen auxiliary voltage 5 5 Fusing It is recommended that all voltage lines are fitted with 1 amp HRC fuses 5 6 Earth Ground Connections For safety reasons CT secondary connections should be grounded in accordance with local regulations Table 4 RS 485 Set up Code Note Codes not listed in the table above may give rise to unpredictable results including loss of communication Ex...

Страница 14: ...perature 23 C 1 C Pre conditioning 30 min acc to IEC EN 60688 Input Variable Rated Voltage Rated Current Input waveform Sinusoidal Form Factor 1 1107 Input signal frequency 50 60Hz Auxiliary supply voltage Rated Value 1 Auxiliary supply frequency Rated Value 1 Output Load Rn 7 5 V Y2 1 With DC current output signal Rn Y2 1 mA 1 With DC Voltage output signal Miscellaneous Acc to IEC EN 60688 Additi...

Страница 15: ... surface Installation Data Mechanical Housing Lexan 940 polycarbonate Flammability Class V 0 acc To UL 94 self extinguishing non dripping free of halogen Mounting position Rail mounting wall mounting Weight Approx 0 4kg Connection Terminal Connection Element Conventional Screw type terminal with indirect wire pressure Permissible cross section of the connection lead 4 0 mm single wire or 2 x 2 5 m...

Страница 16: ...www zimmer instruments com 16 16 NOTES ...

Отзывы: