10
►
Observe the tightening torque of the mounting screws.
►
Verify the permitted load capacity of the required screw connections in accordance with VDI 2230.
INFORMATION
Further installation information:
• The mounting screws are not included in the scope of delivery.
•
Strength class of the mounting screws is at least 12.9 (DIN EN ISO 4762)
Installation sizes with Ø50-90:
• Mounting screw thread size: M5
• Recommended tightening torque [Nm]: 9.3
Installation sizes with Ø100-160:
• Mounting screw thread size: M6
• Recommended tightening torque [Nm]: 15.7
10.1 Installing the product
WARNING
Risk of injury due to incorrect installation
The disassembly of housing parts decreases the holding torque. If installed incorrectly, there is the possibility of a
complete loss of function.
►
During product installation, follow the order listed in the installation and operating instructions.
NOTICE
►
The authorized connections that are available can be found in the accessories list on our website. The
necessary ordering information can also be found there.
►
Use compressed air in accordance with DIN ISO 8573-1 [4:4:4].
CAUTION
Risk of injury caused by falling parts
Operating pressure that is too high or short-term pressure peaks over the maximum permitted operating pressure
can lead to a fault or the destruction of the product.
The holding torque can decrease.
►
Maintain the maximum permitted operating pressure.
►
Use a pressure relief valve.
INSTALLATION AND OPERATING INSTRUCTIONS:
DKPS1000
DDOC01621 / a
EN / 2022-10-04
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com