Observe the tightening torque of the mounting screws.

 

Verify the permitted load capacity of the required screw connections in accordance with VDI 2230.

INFORMATION

Further installation information:
•  The mounting screws are not included in the scope of delivery.
• 

Strength class of the mounting screws is at least 12.9 (DIN EN ISO 4762)

Installation sizes with Ø50-90:
•  Mounting screw thread size: M5
•  Recommended tightening torque [Nm]: 9.3
Installation sizes with Ø100-160:
•  Mounting screw thread size: M6
•  Recommended tightening torque [Nm]: 15.7

10.1 Installing the product
WARNING

Risk of injury due to incorrect installation

The disassembly of housing parts decreases the holding torque. If installed incorrectly, there is the possibility of a 

complete loss of function.

 

During product installation, follow the order listed in the installation and operating instructions.

NOTICE

 

The authorized connections that are available can be found in the accessories list on our website. The 

necessary ordering information can also be found there.

 

Use compressed air in accordance with DIN ISO 8573-1 [4:4:4].

CAUTION

Risk of injury caused by falling parts

Operating pressure that is too high or short-term pressure peaks over the maximum permitted operating pressure 

can lead to a fault or the destruction of the product.
The holding torque can decrease.

 

Maintain the maximum permitted operating pressure.

 

Use a pressure relief valve.

INSTALLATION AND OPERATING INSTRUCTIONS:

 DKPS1000

DDOC01621 / a

EN / 2022-10-04

Zimmer GmbH • Im Salmenkopf 5 • 

 77866 Rheinau, Germany • 

 +49 7844 9138 0 • www.zimmer-group.com

Содержание DKPS1000 Series

Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Rotary clamping element pneumatic DKPS1000 series DDOC01621 THE KNOW HOW FACTORY www zimmer group com...

Страница 2: ......

Страница 3: ...roduct description 6 5 1 Type plate 6 6 Functional description 7 7 Technical data 7 8 Accessories scope of delivery 8 9 Transportation storage preservation 8 10 Installation 9 10 1 Installing the prod...

Страница 4: ...ing these dangers The warning symbols are assigned according to the type of danger WARNING This notice warns of a situation that is potentially hazardous to personal health Ignoring these notices can...

Страница 5: ...er extreme conditions such as aggressive fluids or abrasive dusts Use of the product as an emergency brake Additional drilled holes or threads Zimmer GmbH shall accept no liability for any damage caus...

Страница 6: ...ce must be performed externally 4 Personnel qualification Installation commissioning and maintenance may only be performed by trained specialists These persons must have read and understood the instal...

Страница 7: ...et on our website This data varies within the series depending on the specific design Please contact Zimmer Customer Service if you have any questions INFORMATION The holding torque is specified in th...

Страница 8: ...nical connections If the product is stored for an extended period the following points are to be observed Keep the storage location as dust free and dry as possible Avoid temperature fluctuations obse...

Страница 9: ...for any residual energy that may be present Make sure that the function of the air relief connections is not impaired by the mounting piece CAUTION Risk of injury due to uncontrolled movements Risk o...

Страница 10: ...alled incorrectly there is the possibility of a complete loss of function During product installation follow the order listed in the installation and operating instructions NOTICE The authorized conne...

Страница 11: ...02 3 A 0 02 0 02 A 0 02 A 3 Mounting surface You can install the product from above via the pneumatic connection or from below via the mirrored drilling pattern to the mounting piece INFORMATION Recom...

Страница 12: ...onnection designated for this purpose Apply the corresponding operating pressure to the product 6 Screw fitting Push the product onto the shaft 7 8 9 Position the product on the mounting piece Loosely...

Страница 13: ...ove the top grub screw bl 4 Remove the bottom grub screw 4 Top grub screw bl Bottom grub screw Insert the bottom grub screw into the connection from above bl Turn the grub screw until it reaches the b...

Страница 14: ...rted properly at the bottom connection bm O Ring Push the product onto the shaft 7 8 9 Position the product on the mounting piece Loosely attach the mounting screws De aerate the product completely Th...

Страница 15: ...e thread sealant Insert the top grub screw into the connection from above Loosely screw in grub screw until the surface of the product and the grub screw are flush bl Bottom grub screw INSTALLATION AN...

Страница 16: ...crew bn Attachment kit bo Countersunk screw INFORMATION For further information on installing the magnetic field sensors refer to the current installation and operating instructions for the product on...

Страница 17: ...ess of the product Depressurize the product Initiate a torque that corresponds to the maximum holding torque of the product Make sure that the shaft does not warp in this status The clamping surfaces...

Страница 18: ...mperature range not observed Even though the product is maintenance free as mentioned above perform a regular visual inspection to check for any damage or contamination Dismantling and reassembling th...

Страница 19: ...llowing harmonized standards have been used DIN EN ISO 12100 Safety of machinery General principles for design Risk assessment and risk reduction DIN EN ISO 4414 Pneumatic fluid power General rules an...