7  Technical data

INFORMATION

 

You can find the information in the technical data sheet on our website.

This data varies within the series, depending on the specific design.

 

Please contact Zimmer Customer Service if you have any questions.

NOTICE

Non-compliance may result in material damage.

Misuse and/or overload of the product due to exceeding the maximum on-time.

 

Adhere to the maximum on-time.

8  Accessories/scope of delivery

INFORMATION

If any accessories not sold or authorized by Zimmer GmbH are used, the function of the product cannot be 

guaranteed. Zimmer GmbH accessories are specifically tailored to the individual products.

 

For optional accessories and those included in the scope of delivery, refer to our website.

9  Transportation/storage/preservation

 

Transport and storage of the product must be done only with the original packaging.

 

If the product has already been installed on the superordinate machine unit, care must be taken during transport to 

ensure that no unexpected movements can occur. 

 

Before commissioning the product and after transport, check all power and communication connections as well as 

all mechanical connections.

 

If the product is stored for an extended period, the following points are to be observed:

 

Keep the storage location as dust-free and dry as possible.

 

Avoid temperature fluctuations.

 

Avoid wind/drafts/water condensation formation.

 

Package the product so that it is protected from corrosion.

 

Place additional desiccant under the film as necessary.

 

Pack the product and do not expose it to direct sunlight during storage.

 

Clean all components. There must be no soiling left on the components.

 

Visually inspect all components.

 

Remove all foreign substances.

 

Seal pneumatic connections with suitable covers.

Zimmer GmbH • Im Salmenkopf 5 • 

 77866 Rheinau, Germany • 

 +49 7844 9138 0 • www.zimmer-group.com

INSTALLATION AND OPERATING INSTRUCTIONS: 

AEPN1100-00-A

DDOC01693 / a

EN / 2023-03-20

Содержание AEPN1100-00-A

Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Unit electro pneumatic AEPN1100 00 A DDOC01693 THE KNOW HOW FACTORY www zimmer group com...

Страница 2: ......

Страница 3: ...eservation 8 10 Installation 9 10 1 Installing the product 10 10 2 Installing the energy supply 11 10 2 1 Connecting consumers 11 10 2 2 Setting the pressure range 12 10 2 3 Installing the wiring 12 1...

Страница 4: ...these dangers The warning symbols are assigned according to the type of danger WARNING This notice warns of a situation that is potentially hazardous to personal health Ignoring these notices can cau...

Страница 5: ...product make sure that the product cannot be actuated by mistake Perform maintenance tasks renovation work or attachment work outside of the machine s danger zone when possible Always adhere to the re...

Страница 6: ...laints about a product with a modified or removed type plate 6 Functional description The product enables the generation and maintenance of pneumatic pressure You can choose between two preset pressur...

Страница 7: ...operation again 24 V DC Warning 2x flashing No motor signal because the temperature of the driver stage is too high Wait until the product has cooled down 24 V DC 3x flashing No motor signal because t...

Страница 8: ...product has already been installed on the superordinate machine unit care must be taken during transport to ensure that no unexpected movements can occur Before commissioning the product and after tra...

Страница 9: ...ement of the product when the power supply is connected Switch off the power supply to the machine before carrying out any work Secure the power supply against being switched on unintentionally Check...

Страница 10: ...found in the accessories list on our website The necessary ordering information can also be found there NOTICE Material damage from overheating of the product This can shorten the service life of the...

Страница 11: ...consumers and compare this value with the values to be observed Remove the seal with an Allen key 1 Pneumatic connection 2 Seal Insert the screw fitting into the connection designated for this purpose...

Страница 12: ...rial damage Secure the electrical supply lines to be mounted with a suitable strain relief to prevent the uncontrolled removal of the pins Connect the product according to its assignment diagram 1 1 E...

Страница 13: ...the pressure range 5 Input for valve 1 Signal P1 24 V DC opens valve 1 6 Input for valve 2 Signal P2 24 V DC opens valve 2 7 Analog output 0 to 10 V DC output Proportional to the pressure in bar 0 V...

Страница 14: ...check the operational readiness of the product with suitable electrical consumers Check all mounting screws for the prescribed tightening torque Check all connections for leaks Check the operating pr...

Страница 15: ...d Permissible humidity not observed Moist wet environment Unprotected environment Even though the product is maintenance free as mentioned above perform a regular visual inspection to check for any da...

Страница 16: ...eumatic Type designation AEPN1100 00 A conforms to the requirements of the directive in its design and the version we put on the market Michael Hoch Rheinau Germany 2022 09 06 Authorized representativ...

Страница 17: ...have been used DIN EN ISO 12100 Safety of machinery General principles for design Risk assessment and risk reduction DIN EN ISO 13732 1 Ergonomics of the thermal environment Methods for the assessmen...

Отзывы: