background image

AccuMix Mixing System: AccuFill Mixing Technique

1

  Transfer the tray to the 

sterile field (back table). 
Remove the mixing syringe 
and set upright in the 
tray groove; lift funnel to 
extend syringe. 

7

  Remove mixing syringe 

from tray. Remove plunger 
sleeve from plunger stem. 

DO NOT DISCARD SLEEVE!

 

8

  Thoroughly mix powder 

and saline for 60 strokes 
(~60 seconds). Twist and 
rotate while plunging 
until mix takes “paste” 
consistency.

9

  Remove blue plug. 

Reattach sleeve to stem, 
with stem fully extended.

10

  Holding syringe with cap 

upright, expel excess air 
from syringe. Connect the 
first 1 cc syringe. Inject 
AccuFill BSM into syringe. 
Repeat for remaining 
syringes.

11

  Transfer filled syringes 

to operative field.

2

  Remove vial of AccuFill 

powder from jar. Empty 
powder into funnel; 
tap until powder enters 
syringe.

3

  Remove funnel; fully 

tighten cap and plug. 
Remove blue plug and  
set in sterile tray. 

DO 

NOT DISCARD PLUG!

SET UP

MIX

HYDRATE

TRANSFER

4

  Withdraw saline from vial using the saline 

syringe and adaptor. 

P/N 201.150 (5 cc AccuFill BSM)

• 3.0 cc Saline
• Alternative: 3.4 cc Blood

P/N 201.130 (3 cc AccuFill BSM)

• 2.0 cc Saline
• Alternative: 2.3 cc Blood

5

  Connect Saline syringe to white cap; tighten. 

Inject Saline into powder; pull up on syringe 
plunger to pull excess air into saline syringe. 
Inject again, to ensure ALL SALINE FLOWS 
INTO POWDER, then repeat to release 
pressure.

6

  Remove saline syringe; set it in the sterile 

tray. Attach blue plug to cap.

NOTE: Do not empty entire contents of saline vial into 
AccuFill BSM powder. Measure and use only the exact 
volume noted above.

All content herein is protected by copyright, trademarks and 
other intellectual property rights, as applicable, owned by or 
licensed to Zimmer Biomet or its affiliates unless otherwise 
indicated, and must not be redistributed, duplicated or 
disclosed, in whole or in part, without the express written 
consent of Zimmer Biomet. This material is intended for 
health care professionals and the Zimmer Biomet sales 
force. Distribution to any other recipient is prohibited. Not 
for distribution in France. For product information, including 
indications, contraindications, warnings, precautions, 
potential adverse effects and patient counseling information, 
see the package insert and www.zimmerbiomet.com. Check 
for country product clearances and reference product specific 
instructions for use.

AccuFill

®

 BSM is Manufactured by ETEX Corporation,  

38 Sidney Street, Cambridge, MA 02139 USA • etexcorp.com 

AccuMix

®

 is Manufactured by: Zimmer Knee Creations,  

841 Springdale Drive, Exton, PA 19341 USA

©2017 Zimmer Biomet

1102.1-EMEA-en-REV0517

Authorized Representative

Zimmer GmbH 
Sulzerallee 8
8404 Winterthur
Switzerland

Legal Manufacturer

ETEX Corporation
38 Sidney Street,
Cambridge, MA 02139
USA

Legal Manufacturer

Zimmer Knee Creations 
841 Springdale Drive 
Exton, PA 19341
USA

www.zimmerbiomet.com