background image

F

C

Dual Seal Certification

 

Meets ANSI/ISA-12.27.01-2003 dual seal certification

 

Annunciation Check Valve 
(a dual seal feature) 

 

Visually indicates a primary seal failure. 
Unlike open holes found on competitive models the Robinson check 
valve prevents moisture and debris from contaminating internal  
components. 

Certification Areas

 

Class 1 - Flammable Gas or Vapor, Division 1 - Intermittent Hazard 

Gas Groups B, C, D 

Ensures safety for Hydrogen, Ethylene and Propane in environment 

IEC 

Robinson Pressure Switch has been tested to international standards. 

External Adjustment

 

Simply rotate knurled adjustment collar to increase or decrease pres-
sure setting.

 

Security/Lockout 

To prevent tampering or unauthorized use of the Pressure Switch a Car 
Seal lockout devise can be installed on three components 1) electrical 
enclosure cover 2) calibration screw/cap, and 3) set point adjustment 
collar. 

Process Connection NACE 
(for sour service)

 

Process Connection Materials are chosen in accordance to NACE 
MR0175-2003

 

Piston Orientation

 

Eliminate the need for pulsation dampening

 

Field Service

 

Microswitch replaceable, no need to disassemble Pressure Switch.

 

Diaphragm Servicing 

Diaphragm can be replaced without disassembling Pressure Switch , 
Pin socket available for Diaphragm Nut, contact Robinson Pressure 
Controls. 

Low Ownership Costs

 

Maintenance kits are available to renew Pressure Switch for service. 

Cool Running Micro Switch 

Microswitch life is greatly extended 

as this pressure switch is  

engineered to provide a much lower electrical enclosure temperature. 

Features 

Recommend Service 

7.1 

3 month interval 

- Verify operation by pressure testing, most importantly prior to cold 

weather season. 

7.2 

Ensure Annunciation port (breathe cap/check valve) is free from obstruction. 

7.3 

Any amount of leakage no matter how slight indicates a primary seal failure and the 
switch will need to be removed from service and rebuilt. 

ZIMCO INSTRUMENTATION INC.

11141 15 Street NE, Calgary, AB, T3K 0Z5, Canada 

Phone: 

403-253-8320 

Email: 

[email protected] 

Website: 

www.zimco.ca

 

Содержание RS74A-750F

Страница 1: ...A 750F RS74M 750F High Temp Pressure Switch Installation Operation Manual Hazardous Location Pressure Switch 11141 15 Street NE Calgary AB T3K 0Z5 Canada Phone 403 253 8320 Email info zimco ca Website www zimco ca ...

Страница 2: ... Knurled Pipe Strap Wrench Area Process Connection Trim Bushing Adjustment Collar 1 Safety 1 1 Power supply must be disconnected before installation calibration and maintenance 1 2 Keep all components dry and free from damage 1 3 Review applicable standards to ensure Robinson Pressure Switch is the correct switch for the application 1 4 Personnel must wear appropriate safety approved apparel for w...

Страница 3: ...hex key to loosen the Enclosure Cover Security feature 3 2 Use a spanner wrench 1 4 pin 2 4 3 4 span to break loose the Enclosure Cover and Complete removal by hand 3 3 Connect wires to micro switch as required 3 4 Thread 1 2 MNPT electrical cord Union into the Electrical Port located on the side of the electrical enclosure housing 5 Turns 3 5 Thread Enclosure Cover back onto the Electrical Enclos...

Страница 4: ...ning of Pressure Adjusting Collar 4 2 Pressure Setting Turn Collar Clockwise to Increase Pressure Setting Turn Collar Counter Clockwise to Decrease Pressure Setting 4 3 Tighten Cap Screw Tighten Cap Screw to lock Pressure Adjusting Collar in position 5 Notes Regarding Calibration 5 1 Calibration is not required after re setting verifying trip pressure 5 2 Calibration micro switch gap setting is re...

Страница 5: ...0F Manual Reset Figure 6 IMPORTANT INFORMATION about Process Temperature Testing Pressure Switches with the minimum Class 1 Div 1 name plate markings do not meet CSA C22 2 No E60079 0 2007 which requires a maximum process temperature to be applied for explosion proof test ing All Robinson Pressure Switches in addition to meeting the minimum Class 1 Div 1 have also been tem perature tested to CSA C...

Страница 6: ...service Process Connection Materials are chosen in accordance to NACE MR0175 2003 Piston Orientation Eliminate the need for pulsation dampening Field Service Microswitch replaceable no need to disassemble Pressure Switch Diaphragm Servicing Diaphragm can be replaced without disassembling Pressure Switch Pin socket available for Diaphragm Nut contact Robinson Pressure Controls Low Ownership Costs M...

Страница 7: ... train its employees and contractors in the safe use of Robinson products in con nec on with the specific applica on While the informa on and specifica ons contained in this literature are believed to be accurate they are sup plied for informa ve purposes only and should not be considered cer fied or as a guarantee of sa sfactory re sults by reliance thereon Nothing contained herein is to be construe...

Отзывы: