background image

Z8ENCORE000ZAC
Z8 Encore!

®

 Smart Cable

UM016207-0508

Page 4 of 6

2. Select 

Configuration: Debug

 in the drop-down 

List

 box in the upper left corner of 

the 

Settings

 dialog box.

3. Select 

Debugger

 

 

Target Name

 

 

Z8F64200100KITG

 or 

Z8F0800100KITG

.

4. Select 

Debugger

 

 

Target

 

 

Setup

.

5. Select either 

Clock Frequency

 or 

Other

. If you select 

Other

, enter the X1 Crystal 

frequency in units of MHZ. Click 

OK

.

6. Select 

Debugger

 

 

Debug Tool

 

 

SerialSmartCable

7. Select 

Debugger

 

 

Debug Tool

 

 

Setup

8. Select the appropriate COM port and Baud Rate.

Figure 4

 displays the connection of Smart Cable and Z8 Encore!

®

 device.

Figure 4. Connection Between Smart Cable and Z8 Encore!

 

Device

Содержание Z8 Encore! Smart Cable

Страница 1: ...converts the RS 232 signals into the 3 3 V bidirectional open drain signals required to communicate using the DBG pin to the Zilog on chip debugger of the Z8 Encore The Smart Cable features a 9 pin DB serial connector on one end and a box with a 6 pin DBG Interface Connector on the other end The development kit includes the following see Figure 1 Smart Cable User Manual Figure 1 Z8 Encore Smart Ca...

Страница 2: ...ctor see Figure 2 Figure 2 Connecting the Z8 Encore Smart Cable to Your Computer Connecting the Smart Cable to Your Development Board To use the Z8 Encore Smart Cable connect the application board to the Smart Cable 6 pin DBG connector Ensure that Pin 1 of the application lines up with Pin 1 of the DBG connector indicated by the horizontal vertical groove over the Pin 1 placement see Figure 3 on p...

Страница 3: ...tion board The minimum signal connections required to connect the Z8 Encore to the Smart Cable are the AVDD VDD AVSS VSS and the DBG pin signals The AVDD must be externally connected to the VDD The AVSS must also be externally connected to the VSS The Z8 Encore must be clocked to generate the DBG timing signals For the recommended crystal oscillator circuit refer to Product Specification of target...

Страница 4: ...Z8F0800100KITG 4 Select Debugger Target Setup 5 Select either Clock Frequency or Other If you select Other enter the X1 Crystal frequency in units of MHZ Click OK 6 Select Debugger Debug Tool SerialSmartCable 7 Select Debugger Debug Tool Setup 8 Select the appropriate COM port and Baud Rate Figure 4 displays the connection of Smart Cable and Z8 Encore device Figure 4 Connection Between Smart Cable...

Страница 5: ...7 0508 Page 5 of 6 Compatibility with Microsoft Operating Systems The Z8 Encore Smart Cable is compatible with the following Microsoft operating sys tems when connected directly to the serial port of the PC WIN98E WIN NT WIN2000 WIN XP WIN VISTA ...

Страница 6: ...asonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness Document Disclaimer 2008 by Zilog Inc All rights reserved Information in this publication concerning the devices applications or technology described is intended to suggest possible uses and may be superseded ZILOG INC DOES NOT ASSUME LIABILITY FOR OR PROVIDE A REPRESENTATION OF ACC...

Страница 7: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information ZiLOG Z8ENCORE000ZAC ...

Отзывы: