![Zikodrive ZD10UART Series Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/zikodrive/zd10uart-series/zd10uart-series_operating-manual_3711670028.webp)
28
Zikodrive Motor Controllers, Unit 4B, Top Land Country Business Park, Cragg Vale, Hebden Bridge, West Yorkshire,
UK, HX7 5RW
–
www.Zikodrive.com
- +44 (0)333 123 1730
M_STEP (0x10)
The M_STEP register carries the value of the Microstepping resolution carried out by the ZikoDrive
controller. The resolutions can be set between full step and 128 Microsteps per step.
The following commands depending on the Microstep resolution for correct step counting and
absolute positioning:
•
RUN_STPS
•
MOV_HOME
•
MOV_ABS
Please Note
–
Changing the M_STEP at any time will put the motor outputs into a high impedance
state (same as setting HOLD_CUR = 0x00).
IMPORTANT
–
DO NOT CHANGE THE MICROSTEP RESOLUTION DURING ABSOLUTE POSITIONING
SEQUENCE AS DOING SO WILL MAKE THE DRIVER LOSE POSITION.
VERY IMPORTANT
IF THE MODE IS CHANGED FROM PRECISION MODE TO STANDARD
MODE,
YOU MUST
MODIFY ALL THE CURRENT SETTINGS OR EXCESSIVE CURRENT MAY
PERMANENTLY DAMAGE THE ZIKODRIVE OR THE MOTOR...
Precision Mode
The precision mode allows the ZikoDrive controller to drive stepper motors with a very smooth
and very accurate position ability with 128 Microsteps per step resolution. The precision mode
operates by sending a PWM voltage into each motor phase to obtain a high resolution. However,
as this mode does not directly monitor the motor current, the motor may be more susceptible to
motor resonance.
This Mode is more suited for lower speed (a couple of hundred RPM) high precision applications.