background image

Matrix Switcher Series

User Manual 

78 

 

D-2.4 ACK Type D 

ACK Byte + LB + INF + OP + IP + Name 1 + Name 2 + Name 3 +.....+ CRC Byte 

Name 

Bit 7 

Bit 6 

Bit 5 

Bit 4 

Bit 3 

Bit 2 

Bit 1 

Bit 0 

AB 

ACC 

Device ID (0 - 31) 

LB 

Length for the total data bytes (INFO +.....+ Name n) 

INFO 

Audio 

Video 

Extend 

Total Memory Location (0 - 15) 

OP 

Total Output Port 

IP 

Total Input Port 

NB 1 

Device Name (ASCII code) 

… 

 

NB n 

Device Name (ASCII code) 

CB 

CRC 

AB & CB:

 These are the same as the ACK Type A. 

LB: 

LB value is the total length of the data bytes, not include the AB, LB and CB.   

The maximum LB value of the ACK Type D is 19. 

INFO:

 Device information 

Bit  7:  1  -  Support  Audio  switch  tools  request.  (Request  0x02,  0x04,  0x06  and 

0x08) 

0 - Not support Audio switch tools request. 

Bit  6:  1  -  Support  Video  switch  tools  request.  (Request  0x01,  0x03,  0x05  and 

0x07) 

0 - Not support Video switch tools request. 

Bit 5:  1 - Extended information exists. (Request 0x3F [0x01]) 

0 - Extended information does not exist. 

Bit 4: Reserve, always 0. 

Bit 3~0: Total Memory location ranges from 0 to 15. 

 

Request [Index], if 0x3F [0x01] 

 Request = 0x3F and Index = 0x01 

OP:

 The total number of output. 

IP:

 The total number of input. 

NB:

 Device Name (ASCII code). (The maximum length is 16) 

 

Содержание HX-1616

Страница 1: ...Matrix Switching System User Manual User Manual Matrix Switcher 4x4 8x8 16x16 HX 44 HX 88 HX 1616 V 2012 HX 4881616 00 Copyright and Trademarks...

Страница 2: ...g to their respective companies Before You Begin Follow all instructions marked on the device during using Do not attempt to maintain the device by yourself any faults please contact your vendor Provi...

Страница 3: ...6 4 Power Connection 21 6 5 Matrix Switcher Remote Control 22 6 6 Ports and Switchers 23 6 6 1 RS 232 23 6 6 2 RS 485 25 6 6 3 LAN Port 27 6 6 4 DIP Switcher 8 Pins 28 6 6 5 DIP Switcher 2 Pins 28 6 6...

Страница 4: ...x Switcher Remote Controller 64 Appendix B IR Mini Controller 65 Appendix C Firmware Upgrade 66 Appendix D RS 232 Communication Protocol 69 D 1 Host Request 69 D 1 1 Device Byte 69 D 1 2 Request Byte...

Страница 5: ...put source signal to one or more HDCP compliant displays All to one one to all combination HX 44 88 1616 HDBT matrix switchers are ideal for use in bars restaurants commercial medical military governm...

Страница 6: ...tchers 1 2 Packing Or Or HDMI Matrix Switcher 1 HX 44 HX 88 or HX 1616 RS 232 Communication Connected Cable 1 Power Cord 1 IR Receiver Cable 1 LAN Line 1 Female 1x5 Pole Captive Screw Socket 2 Matrix...

Страница 7: ...Centralized control upon 32 series connections via RS 485 Memory control up to 8 sets HX 44 only up to 4 sets Support resolution up to 4K x 2K 30Hz 8 bit or 1080P 60Hz 12 bit Support original 3D pass...

Страница 8: ...Mini Controller to select the input channel through Output configuration Support RS 232 control Support RS 485 serial control Support Ethernet control Internal universal power supply 1U rack for HX 4...

Страница 9: ...ck Aluminum Mounting Rack mountable 1U rack mount kits for HX 44 2U rack mount kits for HX 88 3U rack mount kits for HX 1616 Weight HX 44 3550g HX 88 4250g HX 1616 7500g Dimensions LxWxH HX 44 332x482...

Страница 10: ...J45 4 Device Installation The Matrix Switcher has a black metallic housing It can be placed on a sturdy desk directly or installed on a 1U HX 44 2U HX 88 or 3U HX 1616 19in bracket See below Figure 4...

Страница 11: ...for 4 Output Input Keys HX 88 supports up to 8 Output Input switching keys on the Front Panel allowing you to switch signal quickly Figure 5 2 HX 88 Front Panel for 8 Output Input Keys HX 1616 support...

Страница 12: ...isable all the displayed switching settings In addition to switching port menu press OFF key can return to the main screen during implementing in other menu You can also press OFF key to disable the l...

Страница 13: ...tatus switching if the previously saving channel is selected Press and hold STO and RCL keys simultaneously at least 1 sec to restore to factory default values HX 44 Memory control only up to 4 sets A...

Страница 14: ...output jacks The HX 44 signal input output terminal channels are numbered as IN1 4 OUT1 4 channels Figure 5 5 HX 88 Rear Panel for 8 Output Input Jacks HX 88 supports up to 8 input jacks HDMI Type A a...

Страница 15: ...computer then can be deployed to control the Matrix Switcher after installing of application software Refer to 7 1 Software Introduction for a software control or Appendix D RS 232 Communication Proto...

Страница 16: ...ut jacks are connected to extensible accessory devices HVX 100 R for HDTVs projectors or other sink devices connection OUTPUT1 8 or 16 RJ45 jacks are only used for extender HVX 100 R connection IR Tx1...

Страница 17: ...Connections The HX 44 HX 88 HX 1616 supports up to 2 4 8 I O modules for reparation or upgrade Each module can be configured individually based on module number You can search these module numbers by...

Страница 18: ...Matrix Switcher Series User Manual 17 Figure 6 4 Modules Deployment...

Страница 19: ...DMI jack of the Blu ray DVD player graphics workstations number displays Use the Cat 5e cable to connect the output RJ45 jack No 1 No 4 8 or 16 to the RJ45 jack of extenders HVX 100 R Through the exte...

Страница 20: ...Encryption 6 1 2 Output Cable HDBaseT was designed to provide Full HD performance up to 100 meters of Cat 5e or superior cables In a typical installation the cable is stretched to its full length bet...

Страница 21: ...d IR Blaster Cable can be connected to IR TX ports on the rear panel Support you an IR channel to control the player from TV or control the TV from player Support all kinds of IR frequency band IR pas...

Страница 22: ...s difficult for you to aim at IR Receiver on the front panel due to the location of Matrix switcher please connect IR Receiver Cable to the IR EXT port located on the rear panel for optional position...

Страница 23: ...n software Aside from using the front panel keys for switching operation you are also permitted to use the RS 232 connection port for remote operation Figure 6 10 RS 232 and Control PC connection Matr...

Страница 24: ...anel for key switching operation you can also use the RS 232 or RS 485 serial communication port to carry out remote operation 6 6 1 RS 232 The RS 232 Pin functions are described as below Pin No Abbre...

Страница 25: ...Switcher Series User Manual 24 Figure 6 12 a RS 232 From Female DB9 PC to Male DB9 Matrix Figure 6 12 b RS 232 From Female DB9 PC to Male DB9 Matrix Figure 6 13 RS 232 From Female DB25 PC to Male DB9...

Страница 26: ...an be used effectively over long distances and in electrically noisy environments This Matrix Switcher supports up to two RS 485 ports allows you to control more than one Matrix Switcher If the master...

Страница 27: ...Matrix Switcher Series User Manual 26 Figure 6 16 RS 485 Connection for HX 1616 Figure 6 17 RS 485 Connection for HX 88 and HX 1616...

Страница 28: ...5 RX RX Received Data RS 232 and RS 485 baud rates 9600bps no odd or even calibration address 8bit data transmission address 1bit stop address 96 N 8 1 6 6 3 LAN Port This Matrix Switcher supports a n...

Страница 29: ...isable C DIP Switcher Pin 7 Switch between RS 232 port and LAN port connection ON RS 232 OFF LAN D DIP Switcher Pin 8 Reset the web server IP address to 192 168 0 3 The steps are as below 1 Please adj...

Страница 30: ...Switching Positions SW5 SW4 SW3 SW2 SW1 0 00 00000 ON ON ON ON ON 1 01 00001 ON ON ON ON OFF 2 02 00010 ON ON ON OFF ON 3 03 00011 ON ON ON OFF OFF 4 04 00100 ON ON OFF ON ON 5 05 00101 ON ON OFF ON O...

Страница 31: ...r Manual 30 25 19 11001 OFF OFF ON ON OFF 26 1A 11010 OFF OFF ON OFF ON 27 1B 11011 OFF OFF ON OFF OFF 28 1C 11100 OFF OFF OFF ON ON 29 1D 11101 OFF OFF OFF ON OFF 30 1E 11110 OFF OFF OFF OFF ON 31 1F...

Страница 32: ...matrix testing and application The software operation environment is as below Window98 2000 NT XP operating systems 32M internal memory or above 10M hard disk space or above CD ROM At least one seria...

Страница 33: ...er to the previous section 6 6 1 RS 232 7 2 Matrix Configuration After finishing installation click to active AV Matrix Application In the Options window select the connected PC Port number and Baud r...

Страница 34: ...all output ports for audio video EDID Type FIX fix mode and TV1 access the first output channel selection key FIX mode The Matrix Switcher will supply a set of fixed EDID values to support up to only...

Страница 35: ...select the Output number keys 002 then select 003 and final select 004 to the right of the blue configuration area and select the Input number key 001 to the bottom Then press consecutively the previo...

Страница 36: ...x Application configuration When the device name located on the left of main configuration window is empty you can click the Scan to research and update the device ID and Name and other related inform...

Страница 37: ...e 7 4 a below Figure 7 4 Disconnect Function Key a for HX 1616 Reference Follow the steps as below to disable the output ports including port 003 002 and 001 Step 1 First press down the output number...

Страница 38: ...Matrix Switcher Series User Manual 37 The final results will be as shown in Figure 7 4 b below Figure 7 4 Disconnect Function Key b for HX 1616 Reference...

Страница 39: ...ume Bass Treble Subwoofer and Delay by sliding the scrollbar You can also enable disable the Mute function here Figure 7 5 Audio Configuration Window Mute Function Description To mute the volume A spe...

Страница 40: ...One Port Configuration A specific example of Mute all function is described below Click Select all check box all of configuration sections will become as light blue block then click Mute check box to...

Страница 41: ...Matrix Switcher Series User Manual 40 Figure 7 7 Mute All Ports Configuration...

Страница 42: ...ously Beside all ports for EDID functions are also processed entirely You cannot configure the port separately FIX mode The Matrix Switcher will supply a set of fixed EDID values to support up to only...

Страница 43: ...nput output switching relations to Location 1 First select Location 1 as shown below Then click the Save key to save all the present input output switching relations to Location 1 Figure 7 9 Retrieve...

Страница 44: ...select one of the COM ports as shown in Figure 7 11 b for an example in Baud rate select 9600 for signal transmission as shown in Figure 7 11 a 7 2 7 Other Application In the right main window displa...

Страница 45: ...mand Code Communication Protocol Baud rate 9600bps no odd or even calibration bit address 8bit transmission address 1bit stop address Please refer to the Command list pdf in the CD ROM for more relati...

Страница 46: ...ated on the rear panel Beside please adjust the DIPs to LAN and Master for the web control device Set Click this button to set the connected combinations both output and input ports OFF Disable the en...

Страница 47: ...n the window the all channels output will become 5 value Figure 7 14 All Output Check Box Function AV Link Link between audio and video Key In A Hot key that is for key in the value 0 99 quickly After...

Страница 48: ...s 7 3 2 Video Configuration For video configuration click Video button directly to pop up Video Settings window Figure 7 17 Video Operation In Video Settings window you can click Change button to swit...

Страница 49: ...tal Memory Total Output and Total Input information Click Refresh button to renew related information in real time Figure 7 21 Device Status Information 7 3 4 Device Output View When your Matrix Switc...

Страница 50: ...2 3 and 4 output channel 3 inputs to channel 1 output Figure 7 23 AV Matrix Control for HX 1616 Reference Step 1 For channel 2 3 4 Output please key in the value 1 in the Audio fields Step 2 For chan...

Страница 51: ...g relations to Location 2 First select Location 2 as shown in the figure below Then click the Save button to save the present input output switching relations to Location 2 Retrieve Function Descripti...

Страница 52: ...ure 7 25 Network Settings In the Network Settings window you can set the IP information by yourself Fix IP or click the Enable DHCP check box to get the IP from the DHCP Float IP Click the Default but...

Страница 53: ...e entire connected Device name will be showed on the Console List as Figure 7 26 For this model the software utility will show at least 1 up to 32 devices The example as below shows you an ID 0 for th...

Страница 54: ...xample 1 Switch the NO 1 input signal to the NO 2 output channel Key LCD Display Operation HX 44 1 Press the NO 2 key of the output channel then the input channel will begin to flicker HX 88 HX 1616 H...

Страница 55: ...ut channels Key LCD Display Operation HX 44 1 Press the NO 1 key of the output channel then the input channel will begin to flicker HX 88 HX 1616 HX 44 2 Press the NO 1 key of the Input channel HX 88...

Страница 56: ...ual 55 HX 1616 HX 44 4 Press the NO 2 key of the Input channel HX 88 HX 1616 Example 3 All settings Key LCD Display Operation HX 44 1 Press the ALL key on the front panel and then press the OFF key to...

Страница 57: ...icate all outputs will switch to selected inputs E g Input is 4 HX 88 2a Press ALL key then select input 8 that indicate all outputs will switch to selected inputs E g Input is 8 HX 1616 2b Press ALL...

Страница 58: ...s the STO key on the front panel The Store to Memory begins to flicker about 8 seconds HX 88 HX 1616 HX 44 2 Press the IN1 key or OUT1 key to save the setting in the NO 1 memory location HX 88 HX 1616...

Страница 59: ...1616 Example 5 STO and RCL combinations restore to factory default values Key LCD Display Operation HX 44 1 Press and hold the STO and RCL keys about 2 3 seconds simultaneously on the front panel to r...

Страница 60: ...59 HX 44 2 After finish resetting All of settings will restore to the factory default values HX 88 HX 1616 Example 6 EDID functions Key LCD Display Operation HX 88 Press the EDID key to switch FIX an...

Страница 61: ...44 Press the PLUG key individually to show you the status of I O jack O is specified for the I O jack is used and X is specified for unused HX 88 HX 1616 Example 8 INFO functions Key LCD Display Opera...

Страница 62: ...Operation HX 44 1 Press the PLUG and INFO keys simultaneously on the front panel The screen will show you the firmware version of module HX 88 HX 1616 HX 44 2 If one of modules firmware upgrade is fa...

Страница 63: ...lso check if the computer communication port is in good order Check the ID address and DIP Switcher are configured correctly Refer to 6 6 6 Device ID Settings and 6 6 5 DIP Switcher 2 Pins 4 What to d...

Страница 64: ...of the product please send for repair by qualified technical engineer 7 What to do if operation and function failure occurred Answer Check if the equipment and the Matrix system are in proper connecti...

Страница 65: ...o control the channels and video features switch of Matrix Switcher through remote controller OSD SCAN AUDIO VIDEO and 10 keys are useless ID key is the same as INFO function on the front panel Power...

Страница 66: ...avoid the event occurs described above you can configure the positions of your IR Receivers based on different environments The IR Mini Controller is optional 0 9 keys are used for channel selection...

Страница 67: ...our device from web server Follow the steps as below to upgrade the firmware 1 Open the Browser on your PC key in the default IP address http 192 168 0 3 to login the AV MA TRIX Control configuration...

Страница 68: ...allow you to select target device based on ID 0 to 31 for upgrading firmware 5 Select 2 Matrix I O Module will allow you to upgrade I O modules You have to decide which device you want to configure an...

Страница 69: ...though the web connection is fail suddenly Please check with the LCD screen to confirm the firmware upgrade has been finished successfully or wait at least 2 minutes then power off to restart your PC...

Страница 70: ...t panel keys for operation you are also permitted to use the RS 232 connection port for remote operation D 1 Host Request A standard command is 5 bytes Device Request Index Value CRC Byte 1 Device Byt...

Страница 71: ...Status Setting Memory A 2 3 0x05 Recall Video Status Setting Memory A 2 0x06 Recall Audio Status Setting Memory A 2 0x07 Request Video Output Channel Output Memory B 0x08 Request Audio Output Channel...

Страница 72: ...ontrol Audio Output Delay High Output Delay2 A 2 0X1F Request Audio Output Delay High Output Memory B Video Control 0x20 Select Input EDID Type 0 EDID A 2 0x21 Request Input EDID Type 1 0 B Device Inf...

Страница 73: ...quest List and Table Command Index List Table Command Index List Index Description Output The output that will be selected Port 1 1 Port 2 2 Port n n 0 All outputs Input The input that will be selecte...

Страница 74: ...Status Can t be stored Enable 1 Enable Status example Mute Plug 0 Disable Status example Un mute Unplug Level Level Range 0 100 0x81 Increase a step 0x82 Decrease a step Delay Audio delay time is 16...

Страница 75: ...2F 71 93 CD 90 11 4F AD F3 70 2E CC 92 D3 8D 6F 31 B2 EC 0E 50 A0 AF F1 13 4D CE 90 72 2C 6D 33 D1 8F 0C 52 B0 EE B0 32 6C 8E D0 53 0D EF B1 F0 AE 4C 12 91 CF 2D 73 C0 CA 94 76 28 AB F5 17 49 08 56 B...

Страница 76: ...CB Type E AB LB EXINF VEINF AEINF PLUG CB D 2 1 ACK Type A ACK Byte CRC Byte Total 2 Bytes Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 AB ACC 0 0 Device ID 0 31 CB CRC ACC The devices acknow...

Страница 77: ...sponse the status refers to the table Request Description Index Value 0x07 Request Video Output Channel Output Input 0x08 Request Audio Output Channel 0x09 Request Video Input Plug Status Input Enable...

Страница 78: ...ERB VERC Version Type A RS 232 Protocol Version contains the VER1 and VER2 ex VER1 VER2 VER1 Data 1 Bit 7 Bit 0 Range 0 99 VER2 Data 2 Bit 7 Bit 0 Range 0 99 If the Data 1 is 0x01 and Data 2 is 0x07 V...

Страница 79: ...data bytes not include the AB LB and CB The maximum LB value of the ACK Type D is 19 INFO Device information Bit 7 1 Support Audio switch tools request Request 0x02 0x04 0x06 and 0x08 0 Not support A...

Страница 80: ...nd 0 The maximum LB is 64 Bytes default 1 The maximum LB is 128 Bytes 2 The maximum LB is 254 Bytes 255 is reserved 3 Reserved The LB value of the Ack packet is not limited by LBMAX If the extended in...

Страница 81: ...the device support Request 0x04 0x02 and 0x06 0x02 PLUG Plug Detect Support Information VIPD Video input plug detection command flag Request 0x09 1 Support Video input plug detection 0 Not support Vi...

Страница 82: ...o 100 meter away by using an Extender and Cat 5e cable HDMI Extender is ideal for Test bench facilities Data Center Help desks Front View Rear View LED Indicators Green LED Off Blink On POWER Power Of...

Страница 83: ...o install easily Specifications Function HVX 100 R HDMI OUT HDMI A Type Female LINK RJ45 Connector IR OUT 3 5 Stereo Jack IR2 IN 3 5 Stereo Jack F W UPGRADE DB9 Female Max Resolution 4K x 2K Cable Dis...

Страница 84: ...Matrix Switcher Series User Manual 83...

Страница 85: ...laster Cable Directions Plug IR Blaster Cable into Extender HX RW IR OUT port located on the front panel IR Emitter HDMI Output Connector Pin Signal Pin Signal 1 TMDS Data 2 11 TMDS Clock Shield 2 TMD...

Страница 86: ...Brown However sometimes especially in demonstrations or in a lab environment the cable is rolled randomly in small turns for convenience The randomly rolled UTP cable suffers additional signal impair...

Страница 87: ...ender HVX 100 R firmware 1 Connect the power cord to the power port on the panel of Extender HVX 100 R The other end of the power cord connected to a suitable power source 2 Connect the control PC and...

Страница 88: ...Matrix Switcher Series User Manual 87 5 The burning windows will pop up and begin to upgrade 6 Final the burning is finish as below...