Temperature monitoring brake chopper/brake resistor (ZETADYN 3C: X-BC, ZAdyn4C: X-MON)
ZETADYN 3C
ZAdyn4C: 2
Temperature monitoring brake chop-
per/brake resistor (X-BC)
Temperature monitoring brake chop-
per/brake resistor (X-MON)
+24V
(2)
->
+24V
(5)
BC
(3)
->
BC
(6)
PE
(4)
->
PE
(7)
Connection terminal X-BC ZETADYN 3C
Connection terminal X-MON ZAdyn4C
Digital inputs (X-IN)
The connection assignment is identical on both ZETADYN 3C and ZAdyn4C. The connecting lead can
be reconnected directly from the ZETADYN 3C to the ZAdyn4C. The connector on the ZAdyn4C must
then be removed.
ZETADYN 3C
ZAdyn4C: 2
Digital inputs (X-I)
Digital inputs (X-IN)
+24V
(1)
->
+24V
(1)
+24V_IN
(2)
->
+24V_IN
(2)
I01
(3)
->
I01
(3)
I02
(4)
->
I02
(4)
I03
(5)
->
I03
(5)
I04
(6)
->
I04
(6)
I05
(7)
->
I05
(7)
I06
(8)
->
I06
(8)
I07
(9)
->
I07
(9)
I08
(10)
->
I08
(10)
GND_IN
(11)
->
GND_IN
(11)
GND
(12)
->
GND
(12)
Technische Information
R-TIA14_12-GB 1528
Part.-No.
8/22