Information
The ZAdyn4C 011-032 requires less space than the ZETADYN 3C. It is possible to replace it without
adapting the switch cabinet.
Ensuring the parameter values of the ZETADYN 3C
In order to continue operating the lift with same travel properties, the same parameter settings must
be made on the ZAdyn4C as on the ZETADYN 3C.
There are two ways of ensuring the parameter values:
Noting the parameters of the ZETADYN 3C
There is a table at the end of this technical information in which you can note the parameter values of
the ZETADYN 3C behind the parameter names. After mechanical and electrical installation, you can
set the parameter values on the ZAdyn4C.
Saving the parameters of the ZETADYN 3C on the memory card
Alternatively, you can save the parameters of the ZETADYN 3C on the memory card and use it to load
them onto the ZAdyn4C.
Pecedure for saving the parameters on the memory card
"
Insert the memory card in the X-MMC card slot on the controller unit (see
fi
gure).
Memory card in the X-MMC card slot
Statistics
->Memory Card
MMC Recorder
Encoder-adjust.
Select
"Memory Card"
menu
Con
fi
rming menu selection
Memory Card
|
-
"
SAV_PAR OFF
|
-
"
ON
Select
"SAV_PAR"
parameter
Con
fi
rming menu selection
Select "SAV_PAR=EIN"
Con
fi
rm with the
key.
Please wait ...
Copy1:_ _ _ _ _ _ _
The parameters are saved.
Mechanical installation
Danger!
It is forbidden to carry out work on electrically live parts.
In frequency inverters of the ZAdyn type, the intermediate circuit (terminals ZK+ / ZK- or +DC / -DC)
are still under voltage even after switching off.
You must wait at least three minutes.
"
Remove all lines connected to the ZETADYN 3C.
"
Remove ZETADYN 3C.
"
Install ZAdyn4C. Observe the installation conditions described in the operating instructions!