6.3.3
Strain relief
Cable ties must be attached to all connecting cables for strain relief. The cable ties must be
fi
xed to
the recesses provided on the housing of the retro
fi
t kit (see
fi
gure in the chapter "Connecting
connecting cables on the retro
fi
t kit/Connection").
6.4
Connecting connecting cables running from the retro
fi
t kit on the ZAdyn4C
6.4.1
Connection
Lead
Connection terminal on ZAdyn4C
X-MON
X-MON, PINs 8-13
X-MT
X-MT
X-STO
X-STO
X-OUT
X-OUT
1
2
3
4
Connection terminals on ZAdyn4C 011-032
1
X-STO
2
X-MT
3
X-MON
4
X-OUT
6.4.2
Strain relief
Cable ties must be attached to all connecting leads for strain relief. Attach the cable ties to the
recesses provided on the housing of the ZAdyn4C.
The shielding of the X-STO and X-IN connecting leads must be connected to earth potential on the
inverter side. Earthing clips are provided on the ZAdyn4C for this purpose.
Technical Information
Electrical installation
R-TIA19_02-D-GB 1942
Part.-No. 00163469-D-GB