1 Thermal contact
5. On-site connection must be made by the customer according to the wiring diagram in the
separate terminal box of the external ventilation.
9 Enclosure
9.1
Technical data
Motor type
ZAtop SM210.60B
ZAtop SM210.70B
Suspension
1:1
2:1
1:1
2:1
typical payload*
[kg]
850
1350
1050
1600
Rated torque
[Nm]
850
1000
Maximum torque
[Nm]
1450
1700
maximum short circut torque
[U/min]
630 bei 25 [U/min]
750 bei 25 [U/min]
permissible radial load
[kg]
4500
4500
Speed
[m/s]
1.6
1.6
Total weight witout traction sheave
[kg]
435
456
Traction sheave
- Diameter
[mm]
320
400
320
400
- Width
[mm]
150
150
150
150
- Rope diameter
[mm]
8
10
8
10
- Standard number of grooves
8
8
10
8
- Standard groove distance
[mm]
17
17
14
17
Table shows typical data, other values possible.
Other rope diameters and groove distances are possible.
* Dependent on travel, compensation ropes may be necessary.
9.1.1
Protection rating
Component
Protection rating
Motor
IP 42
Absolute encoder
IP 40
Brake (electrical)
IP 54
Brake (mechanical)
IP 10
Complete machine
IP 21
Translation of the original operating instructions
ZAtop
–
model series SM210.60B/SM210.70B
Enclosure
$7%$B*%
,QGH[
Part.-No. 01013389-GB (EU-BD 1014)