In the case of 2 or 3 stops:
In the case of 4 or more stops:
"
Give a travel command one
fl
oor higher.
"
Give a travel command two
fl
oors higher.
✓
Cabin accelerates and comes to a standstill. It does not reach the speci
fi
ed
fl
oor. It is possible that
the elevator control system automatically starts a further subsequent travel. In this case allow the
subsequent travel.
"
Subsequently, drive the cabin to the bottom
fl
oor.
"
In order to determine the target values, proceed as follows:
–
Give a travel command to the 2nd lowest
fl
oor.
–
Give a travel command to the bottom
fl
oor.
–
Repeat both these steps several times. Pay attention to the values (HY_)O_A as well as
(HY_)OFFS in the
INFO menu
on
page 03
. The ZAdyn4CA HY adjusts these values in the
course of upward journeys. The ZAdyn4CA HY is programmed for load-free operation when the
values have approached their target value no longer changing only in one direction. The
ZAdyn4CA HY automatically recognises this status displaying it in the
INFO menu
on
page 03
in
the 3.rd line by showing the small dot in bold type.
Dot in the info menu/page 03
It is possible that even after 30 travels the target value is not reached. This can be recognised by the
fact that the small dot in the 3.rd line in the
INFO menu
on
page 03
is not shown in bold type. The
reason is that the ZAdyn4CA HY overcompensates by determining values around a target value which
are
fi
rst higher and then lower. In this case manually calculate an average from the different target
values and programme it in the parameter
Start-up/HY_O_A
or
Start-up/HY_OFFS
. Afterwards the
tuning process for load-free operation is ended and you can continue as normal.
"
Leave the info menu with the key.
"
Set the parameter
Start-up/HY_Auto
to "Off".
Tuning function for load operation
"
Load the cabin with nominal load.
"
Set the parameter
Start-up/HY_Auto
to "3: full 1".
"
Switch to the info menu with the key.
"
With the arrow keys select
page 03
in the
INFO menu
.
In the case of 2 or 3 stops:
In the case of 4 or more stops:
"
Give a travel command one
fl
oor higher.
"
Give a travel command two
fl
oors higher.
✓
Cabin accelerates slightly and comes to a standstill again. It does not reach the speci
fi
ed
fl
oor. It is
possible that the elevator control system used automatically starts a further subsequent travel. In
this case allow the subsequent travel.
"
Subsequently, drive the cabin to the bottom
fl
oor.
"
In order to determine the target value, proceed as follows:
–
Give a travel command to the 2nd lowest
fl
oor.
–
Give a travel command to the bottom
fl
oor.
–
Repeat both these steps several times. Pay attention to the value (HY_)La_V in the
INFO menu
on
page 03
. The ZAdyn4CA HY adjusts this value in the course of upward travels. The
ZAdyn4CA HY is programmed for load operation when the value has approached its target value
no longer changing only in one direction. The ZAdyn4CA HY automatically recognises this status
displaying it in the
INFO menu
on
page 03
in the 3.rd line by showing the small dot in bold type.
Quick Start Guide
ZAdyn4CA HY
Start-up
R-TBA16_01-GB 1845 Index 003
Part.-No. 00163456-GB
16/28
Содержание ZAdyn4CA HY Series
Страница 3: ...9 4 Index 24 Quick Start Guide ZAdyn4CA HY R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 3 28 ...
Страница 25: ...Quick Start Guide ZAdyn4CA HY Index R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 25 28 ...
Страница 26: ...Quick Start Guide ZAdyn4CA HY Index R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 26 28 ...
Страница 27: ...Quick Start Guide ZAdyn4CA HY Index R TBA16_01 GB 1845 Index 003 Part No 00163456 GB 27 28 ...