4 Mounting
4.1 General notes
Attention!
•
Mounting is only to be undertaken by trained service personnel. The system
manufacturer or the machine builder and/or the user is responsible that the inherent
installation and security information are harmonized with the valid standard and
guidelines (EN ISO12100 / 13857).
•
Check the fan for damage, e.g. cracks, dents or damage to the electric cables, before
assembly. Start-up is not allowed in the case of transport damage!
•
The operator is responsible for installation and for ensuring the safety of the device.
Assembly must be carried out by quali
fi
ed personnel in compliance with these
instructions and the motor operating instructions.
•
Take into account easy access for cleaning and maintaining the fan.
•
Prior to installing the fan, check whether safety distances according to EN ISO 13857
are complied with.
–
If the mounting height (danger area) above the reference plane is greater than or
equal to 2700 mm and is not reduced by auxiliary means such as chairs, ladders,
working platforms or
fl
oor space on vehicles, a guard grille is not necessary on the
fan.
–
If people are located in the fan danger area, then the manufacturer or operator of
the complete system shall ensure that hazards are prevented by appropriate
protective constructions which meet the requirements to EN ISO 13857.
•
The custom designs must suit the prevailing conditions.
•
Tighten the fastenings with the speci
fi
ed torques.
•
Drilling chips, screws and other foreign bodies must not be located inside the device!
Before the
fi
rst switch-on, remove any items that may be present (drilling chips,
screws and other foreign objects) from the intake area - risk of injury from any objects
that may
fl
y out!
4.2 Handling
Attention!
•
Wear safety clothing / shoes and cut-resistant safety gloves when handling.
•
Never stand underneath the suspended fan because defective transport equipment
could cause death.
•
Pallets must be secured when unloading and during handling.
•
Fix pallets during transport.
•
Never hold or carry on the impeller.
•
Never hold or carry on the grille(s).
•
Never hold or carry on the cable(s).
•
Check the weight of elements and use suitable lifting and conveying equipment.
•
Lift the fan out of the packaging with a lifting gear (lifting beam). Attachment points are
solely the holes on the housing
fl
ange, motor bed, support plate, motor suspensions,
fastening brackets and any crane eyes of the fan (depending on the shape of the fan).
Assembly instructions
MAXvent
Mounting
L-BAL-F054-GB 2018 Index 005
Part.-No. 00501414-GB
16/32