![Zibro SRE 440 E Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/zibro/sre-440-e/sre-440-e_operating-manual_3798757095.webp)
+
Do not remove any heater components yourself. Always contact your Zibro
dealer for repairs. When the power cord is damaged, it may only be replaced
by an authorised fitter. Use a new cord of the type H05 VV-F.
N
STORAGE (END OF THE HEATING SEASON)
At the end of the heating season, you must store the heater in a dust-free place, if
possible in its original packaging. Unused fuel cannot be used in the next heating
season. We therefore recommend that you burn up all fuel. If there is still some
fuel left, do not throw it away, but dispose of it in accordance with the local
regulations for the disposal of domestic chemical waste. Remove the batteries
from the remote control. Always start the new heating season with fresh fuel.
When you start re-using the heater follow the instructions again
(starting from
section A and as specified)
.
O
TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
1
Let the heater cool down.
2
Remove the removable tank
from the heater and remove the fuel filter
(refer to Section M, Fig. M).
Some drops may leak from the filter; keep a cloth
at hand. Store the fuel filter and the removable tank outside the heater.
3
Place the transportation cap into the position of the fuel filter (Fig. N).
Press it tight. The transportation cap will, as much as possible, prevent oil
leakage from the heater during transport.
4
Always move the heater in an upright position.
5
Make the fixed tank empty with a fuel pump before transportation or in case
of wrong or dirty fuel. First remove the fuel filter and then insert the fuel
pump into the empty fixed tank. Follow the same procedure if the fuel tank
contains water.
P
SPECIFICATIONS
Ignition
electrical
Dimensions (mm)
width
435
Fuel
paraffin
(including base plate) depth
315
Capacity (kW) max.
4,00
height 437
Capacity (kW) min.
1,05
Accessories manual fuel pump
Suitable space (m
3
)
**
65-170
transportation cap
Fuel consumption (l/hr)
*
0,417
Mains
230V
Fuel consumption (g/hr)
*
333
-- AC/50 Hz
Burning time per tank (hr)
*
18,2
Electrical consumption igniter 320 W
Capacity removable tank (litres) 7.6
continuous
24W
Weight (kg)
11,5
Fuse rating 250V, 5A
Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO
2
level (NDIR CO
2
-sensor E-Guard
).
* At maximum setting ** Specified values are indicative
4
83
transportation
cap
N
p074_087_uk_SRE440E.indd 83
04-06-13 15:11