H
HOW THE AIR CONDITIONER WORKS
AUTOMATIC OPERATION
•
When you set the air conditioner in AUTO mode (button 2 on the remote
controller), it will automatically select COOLING, HEATING or FAN only ope-
ration depending on what temperature you have selected and the room
temperature.
•
The air conditioner will control room temperature automatically round the
temperature point set by you.
•
If the AUTO mode is uncomfortable, you can select desired conditions manu-
ally.
ECONOMIC OPERATION
•
When you push SLEEP button
f
during COOLING, HEATING or AUTO opera-
tion, the air conditioner will automatically increase (cooling) or decrease
(heating) 1ºC per hour. The set temperature will be steady 2 hours later. The
fan speed will be automatically controlled.
DEHUMIDIFYING OPERATION
•
The dehumidifying mode will automatically select the dehumidifying opera-
tion based on the difference between the set temperature and the actual
room temperature.
•
The temperature is regulated while dehumidifying by repeatingly turning on
and off of the cooling operation or fan only. The fan speed is LOW.
•
In normal cooling operation the airconditioner will also dehumidify the air.
G
NOTE
When the airconditioner is dehumidifying it is likely that the room temperature will decrease. It is
therefore normal that a hygrostat will measure a higher
relative
humidity. The
absolute
humidity in the room will however be lowered, depending on the amount of moisture produced
in the room (cooking, people etc).
1
1
1
1
G
CAUTION
• The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in
operation (including when the TIMER ON is set).
• Do not operate the air conditioner for long periods with the air flow direction set downward
in cooling or dry mode. Otherwise, condensation may occur on the surface of the horizontal
louver causing moisture to drop.
• Do not move the horizontal louver manually. Always use the AIR DIRECTION
h
or SWING
button
g
. If you move this louver manually, it may malfunction during operation. If the louver
malfunctions, stop the air conditioner once and restart it.
• When the air conditioner is started immediately after it was stopped, the horizontal louver
might not move for approximately 10 seconds.
• Open angle of the horizontal louver should not be set too small, as COOLING or HEATING
performance may be impaired due to too restricted air flow area.
• Do not operate unit with horizontal louver in closed position.
• When the air conditioner is connected to power (initial power), the horizontal louver may
generate a sound for 10 seconds, this is a normal operation.
4
114
Press Sleep button
Press Sleep button
COOLING
HEATING
DEHUMIDIFYING
Set
Tempe-
rature
1 hour
1 hour
1 hour
1 hour
Set
Tempe-
rature
Set temperature
Time
Room
tempe-
rature
Cooling Fan only Cooling Fan only Cooling
man_S18xx_uk.qxd 02-02-2007 11:19 Pagina 114