– 8 –
TIMER OPERATION
ON Timer operation
•
Press the ON/OFF switch. Right after replacing new batteries, set the present time in advance.
•
Set the “ON Time” : Press the “TIME ADJ” button twice.
Adjust the time with the “ , ” button.
Press the “TIME ADJ” button twice.The setting of “ON Time” is completed and the present time appears on the LCD.
•
Set the “ON Timer” : Press the Timer fixing button “ON”.
OFF Timer operation
•
Press the ON/OFF switch. Right after replacing new batteries, set the present time in advance.
•
Set the “OFF Time” : Press the “TIME ADJ” button 3 times.
Adjust the time with the “ , ” button.
Press the “TIME ADJ” button once.The setting of “OFF Time” is completed and the present time appears on the LCD.
•
Set the “OFF Timer” : Press the Timer fixing button “OFF”.
Sleep Timer operation
•
Press the “SLEEP” button during the operation.
•
Set the operating period by pressing the “SLEEP” button until the period designated appears on the LCD.
Timer Cancellation
•
ON/OFF Timer : Press the Timer fixing button “ON”(On Timer) and/or “OFF”(Off Timer) once again.
•
Sleep Timer : Press the “SLEEP” button until the operating period on the LCD disappears.
AIRFLOW DIRECTION CONTROL
Vertical adjustment
When ON/OFF switch is pressed, the vertical louver will move to the adequate positions for each operation
automatically.
Swing of air flow
If air flow direction switch is pressed once, the vertical louver will move within the range of figures.
Fixing the flow direction
If air flow direction switch is pressed again, the vertical louver will be fixed and that position is memorized.
From the next operation the louver will be set at previous position automatically.
Notes :
•
In Swing Mode, the louver automatically moves up and down within the certain range, as the illustration below.
•
There is two different ranges of louver swinging; one is of cooling & dry mode operation and the other is of
heating operation.
OPERATION DETAILS
Level
Approx.10 degrees
Approx.65 degrees
Standard Position
Approx.10
Approx.50
Approx.65
(Cooling/Dry)
(Heating)
degrees
degrees
degrees
Level
Swing of Air Flow
Cooling
Dry
Heating
Содержание S1731
Страница 24: ... 23 ELECTRIC CIRCUIT DIAGRAM S1731Outdoor S1735Outdoor ...
Страница 31: ... 30 PCB AC 377 AC 379 SCHEMATIC DIAGRAM AND PCB S S1731Outdoor S1735Outdoor Bottom View ...
Страница 32: ... 31 FILTER PCB AC 378 SCHEMATIC DIAGRAM AND PCB S S1731Outdoor S1735Outdoor Bottom View ...
Страница 33: ... 32 SCHEMATIC DIAGRAM AC 383 AC 382 AC 359 SCHEMATIC DIAGRAM AND PCB S S1731Indoor S1735Indoor ...
Страница 34: ... 33 SCHEMATIC DIAGRAM AC 377 AC 379 SCHEMATIC DIAGRAM AND PCB S S1731Outdoor S1735Outdoor ...
Страница 35: ... 34 FILTER PCB AC 378 SCHEMATIC DIAGRAM AND PCB S S1731Outdoor S1735Outdoor ...
Страница 47: ... 46 SEMICONDUCTOR PIN FUNCTION Fig 1 Fig 2 Fig 3 5V 0V t 10ms 20 R P M FAN MOTOR 5V 0V t s 5V 0V t 10ms ...
Страница 66: ...ISSUED DEC 2005 RA 42 1 Printed in Japan ...