– 10 –
OPERATION DETAILS
DRY MODE OPERATION
•
The compressor will stop when operational frequency reached the minimum frequency and that condition has
been kept for
★
1 seconds and the room temperature becomes 1.3
℃ lower than it
was set.
•
The compressor will re-start when room temperature becomes 0.7
℃
higher than
it
was set.
•
The operational frequency will be set every
★
2 seconds of operation.
The operational frequency setting will be calculated based on the deviation of the room temperature and the
set temperature on one end and the deviation factor at the time of previous setting on another.
Indoor fan
Selected speed
Stop
Super low
3min.
MAX
MAX
0
Hz
Frequency of
compressor
Designated
temperature
Room temperature
★
3
★
3
MIN
★
4
MIN
★
4
Selected speed
-1.3˚C
0.7˚C
★
1
120
180
★
2
40
60
★
3
68.0Hz
72.0Hz
★
4
32.0Hz
32.0Hz
S 1731
S 1735
Model
Содержание S1731
Страница 24: ... 23 ELECTRIC CIRCUIT DIAGRAM S1731Outdoor S1735Outdoor ...
Страница 31: ... 30 PCB AC 377 AC 379 SCHEMATIC DIAGRAM AND PCB S S1731Outdoor S1735Outdoor Bottom View ...
Страница 32: ... 31 FILTER PCB AC 378 SCHEMATIC DIAGRAM AND PCB S S1731Outdoor S1735Outdoor Bottom View ...
Страница 33: ... 32 SCHEMATIC DIAGRAM AC 383 AC 382 AC 359 SCHEMATIC DIAGRAM AND PCB S S1731Indoor S1735Indoor ...
Страница 34: ... 33 SCHEMATIC DIAGRAM AC 377 AC 379 SCHEMATIC DIAGRAM AND PCB S S1731Outdoor S1735Outdoor ...
Страница 35: ... 34 FILTER PCB AC 378 SCHEMATIC DIAGRAM AND PCB S S1731Outdoor S1735Outdoor ...
Страница 47: ... 46 SEMICONDUCTOR PIN FUNCTION Fig 1 Fig 2 Fig 3 5V 0V t 10ms 20 R P M FAN MOTOR 5V 0V t s 5V 0V t 10ms ...
Страница 66: ...ISSUED DEC 2005 RA 42 1 Printed in Japan ...