Zibro Kamin SRE 156 Скачать руководство пользователя страница 9

exceeds the set temperature by 3°C. Subsequently, when the room temperature has

dropped again to the set temperature, the heater will automatically switch on again. 

Activate the 'SAVE' setting by pressing the appropriate 

key. The SAVE indicator

light will light up (Fig. J). Switch off the function by pressing the SAVE key once

again.

Without the 'SAVE' setting your heater will maintain the set temperature by

approximation as well, by adjusting its heating capacity. 'SAVE' is an economy

setting, which you can use when, for instance, you are not present in the room

or to keep it frost-free.

K

THE 'FUEL' INDICATOR LIGHT

When the FUEL indicator light lights up, there is enough fuel left for another 10

minutes of heater use. The count-down of the remaining heating time can be seen

in the information display 

(Fig. K). Every two minutes an alarm signal is

sounded, warning you to refill the removable tank. If you do not react, the heater

will extinguish by itself. The heater will also sound a warning signal, when it

switches off. The FUEL indicator light will blink, while four lines are blinking in the

information display. You can stop this by pressing the 

button 

once.

Once the heater has used up all its fuel and extinguished, it will take some time,

after the refill, before the heater is completely ready for use again.

L

THE 'VENT' INDICATOR LIGHT

When the VENT indicator light starts blinking, this is a sign that the room is not

vented sufficiently (Fig. L). If you do not provide additional ventilation, the heater

will switch off automatically after some time. If the indicator light continues

blinking after extra ventilation, please contact your Zibro Kamin dealer.

M

MAINTENANCE

Switch off the heater and let it cool down, before you start any maintenance

work. Also disconnect the plug from the mains.

Your Zibro Kamin needs hardly any maintenance. It is, however, important that

you clean the air filter cap 

and the vent filter 

with a vacuum cleaner and the

grid 

 

with a damp cloth, both on a weekly basis. Remove the air filter cap

occasionally (Fig. M) and clean it with soapy water. Prior to reinstallation, make

sure that the air filter cap has fully dried. 

Regularly inspect the fuel filter as well:

Remove the removable tank 

from the heater and remove the fuel filter 

(Fig. N). Some drops may leak from the filter; keep a cloth at hand.

Remove the dirt by tapping the fuel filter upside-down against a hard surface. 

(Never clean it with water!)

Reinstall the fuel filter into the heater.

We  recommend that you remove dust and stains in time with a damp cloth,

because otherwise these may cause stains that are hard to remove.

3

2

1

4

49

J: When the SAVE light

lights up, the heater will

automatically switch on

or off in order to remain

within a specified

temperature range.

N

M

Fuel filter

L: A blinking VENT

indicator light is a sign

that you need extra

ventilation.

K: When the FUEL

indicator light is lit, the

information display will

show the number of

minutes of fuel left in 

the tank.

+

SAVE

TEMP

CLOCK

TIMER

VENT

FUEL

2 0 :

1 0

SET  ROOM

TIMER

VENT

2 0 : 1 5

SET  ROOM

Содержание Kamin SRE 156

Страница 1: ... SRE 156 2 12 22 32 42 52 62 MANUEL D UTILISATION GEBRAUCHSANWEISUNG BRUGSANVISNING INSTRUCCIONES DE USO OPERATING MANUAL ISTRUZIONI D USO GEBRUIKSAANWIJZING 3 2 6 5 4 1 ...

Страница 2: ...Please read these Directions for Use first to ensure maximum lifetime for your Zibro Kamin Your heater comes with a 24 month manufacturer s warranty on all defects in material or workmanship We wish you much warmth and comfort with your Zibro Kamin Yours sincerely PVG International b v Customer Service Department 1 READ THE DIRECTIONS FOR USE FIRST 2 IN CASE OF ANY DOUBT CONTACT YOUR ZIBRO KAMIN D...

Страница 3: ...e of parrafin oil you must first finish up all the remaining fuel in the heater MAIN COMPONENTS Front plate Grid Base plate Lid for removable tank Operation panel Handle Removable tank Air filter cap Vent filter Thermostat Plug cord Information display key Childproof lock Adjustment keys time and temperature TIMER SAVE key Indicator lights Connection weekti mer Remove all packaging materials Fig A...

Страница 4: ...valent Your Zibro Kamin heater has been designed for use with high quality water free pure paraffin oil such as Zibro Plus Only fuels of this kind will ensure clean and proper burning Lower quality fuel may result in increased possibility of malfunctioning incomplete burning reduced heater lifetime smoke and or smells deposits on the grid or mantle Using the right fuel is therefore essential for s...

Страница 5: ...0 Volts AC 50 Hz and set the correct time using the adjustment keys refer to Section C Your Zibro Kamin is now ready for use B FILLING FUEL Do not fill the removable tank in the living room but in a more suitable place there can always be some spillage Follow the procedure below Make sure that the heater is switched off Open the lid and lift the removable tank out of the heater Fig B Note Some dro...

Страница 6: ... the time needs to be set again D IGNITING THE HEATER When used for the first time a new heater may give out a smell for a short while You should therefore provide extra ventilation Always ignite the heater with the button Never use matches or a cigarette lighter Just press the button to ignite the heater The button will start blinking indicating that the ignition procedure has started This will t...

Страница 7: ... temperature at the set time When you want to switch off the heater and ignite it again with the timer all you have to do is press the TIMER key refer to Section G Press the button once to clear the timer setting If you would like more extensive timerpossibilities we advise you to procure the Zibro Kamin weektimer This timer is easy to connect with your Zibro Kamin Heater see available from 2003 G...

Страница 8: ... highest setting the burner will automatically start an autoclean procedure The display will show the autocleaningcode cl 05 running back to cl 00 The procedure takes 5 minutes during which the heater will burn at its lowest setting while the burner autocleans When the burner is clean again the heater will automatically switch back to the highest setting again I CHILDPROOF LOCK The childproof lock...

Страница 9: ...ented sufficiently Fig L If you do not provide additional ventilation the heater will switch off automatically after some time If the indicator light continues blinking after extra ventilation please contact your Zibro Kamin dealer M MAINTENANCE Switch off the heater and let it cool down before you start any maintenance work Also disconnect the plug from the mains Your Zibro Kamin needs hardly any...

Страница 10: ...tank from the heater and remove the fuel filter refer to Section M Fig N Some drops may leak from the filter keep a cloth at hand Store the fuel filter and the removable tank outside the heater Place the transportation cap into the position of the fuel filter Fig O Press it tight Always move the heater in an upright position P SPECIFICATIONS Ignition electrical Dimensions mm width 405 Fuel paraffi...

Страница 11: ...llable burning causing flames to break out Should this happen never try to move the heater but always switch off the heater immediately In case of emergency you may use a fire extinguisher but only a type B extinguisher a carbon dioxide or powder extinguisher 10 TIPS FOR SAFE USE 1 Make sure that children are always aware of the presence of a burning heater 2 Do not move the heater when it is burn...

Страница 12: ...es produits de combustion Contrôle de la qualité de la combustion absence de CO Endurance Intermittence CONSEILS D UTILISATION ET D ENTRETIEN Se reporter à la notice jointe à l appareil et à la plaque de sécurité sur l appareil Référence et numéro de lot ou de série de l article se reporter au produit Distributed in Europe by PVG International B V P O Box 96 5340 AB OSS Pays Bas Tél 31 0 412 69467...

Страница 13: ...E E E E E E E E E E E E E E E E E E E E E E E E E save timer hour min key lock save timer vent fuel 20 15 set room temp clock Q R L P O N M A E E G F D J B C I S K H ...

Страница 14: ...alderas II Comunidad La Alameda C Aurora Boreal 19 28918 LEGANÉS Madrid tel 34 91 611 31 13 fax 34 91 612 73 04 email pvgspain zibro com 4 UNITED KINGDOM Lister Gases Bridge Street Holloway Bank Wednesbury West Midlands WS10 OAW Tel 44 121 506 1818 Fax 44 121 505 1744 email gases lister co uk ITALIA PVG Italy SRL Via Niccolò Copernico 5 50051 CASTELFIORENTINO FI tel 39 571 628500 fax 39 571 628504...