Zhone Technologies, Inc. @Zhone Way, 7001 Oakport St., Oakland, CA 94621 (510) 777-7000 Fax: (510) 777-7001
Figure 2: IMACS-900 Power Cable Location
The Power Supply cable is located on the front of the IMACS-900 and extends between
the top power supply portion of the shelf behind slot F2 and the lower shelf backplane
behind circuit card slot U8.
Note that the brown wire of the cable is oriented to the top of the cable connector.
Cable Removal:
In order to remove the cable, it will be necessary to remove power from the shelf. Prior to
starting, it should be recorded what cards occupy which slots. It is highly recommended
to perform a database backup prior to beginning the procedure (save to flash, save off-
shelf). In order to have room to maneuver, it is recommended that the cards around the
cable connector be removed to allow for plenty of room to work on the shelf.
Procedurally:
1.
Back up system image to flash. On the main login screen, enter ‘Y’ for
system. Select ‘B’ for backup, and change ‘PROTOCOL’ from ASCII to