background image

9

3920-A2-GK47-10

February 2002

Status

Configure

PList

Control

Test

SubHS

Call_Setup

Tlk/Data

Security

Remote

Does not appear in TMp Control mode.

Does not appear in Remote mode.

(Self, Loc_Digital_Loop, and Pattern

appear if the secondary channel is

used. Rem_Digital_Loop does not

appear in TMp mode.)

Choose Address

(TMp Control only)

Choose Password

(TMp only)

Secondary

Prim

(data blckd)

(

ExitRem 

appears

instead of

 Remote

 when

using Remote mode)

UNIX_Dial

(Tributary

only)

Sync_Leased

Async_Leased

Choose Mode

Answer

Originate

TMp

Choose Mode

Control

Trib

Async_Dial

Sync_Dial

Activ

(Operating)

Active

(Saved)

Customer1

Customer2

Factory

Ld EditArea frm:

Choose Function

Save

Active

(Saved)

Customer1

Customer2

"Status"

Displays current status of modem along with

data rate and error control mode.

Dial

Disconnect

Answer

Dial_Standby

or

Return_to_Dial

Change_Directory

Directory Locations 1 – 24

(Dial

Backup

only)

Display Clear Change Add

Acquire

Active

Delete

Skip

Abort

Self

Loc_Analog_Loop

Rem_Digital_Loop

Loc_Digital_Loop

Pattern

(Singleport mode

only)

97-14651-04

Speaker

Reset

Data_Stream

EIA_LEDS

Make_Busy

or

RemoveMakeBusy

Service_Line

or

DiscServLine

Download_Code

(DownloadSoftware)

VF_Thresh_Update

(3921

Plus

only)

Edit StrapGroup

Set_Access_Ctrl

Reset_Security

(Admin Password?)

EditPassWdTable

Set_Answer_Sec

Set_Orig_Secur

Set_Admin_PsWd

DTE_Interface

DTE_Dialer

Line_Dialer

Leased_Line

Test

Security

Dial_Line

V42/MNP/Buffer

Misc

MUX

Copy

Port1 Port2

*

Port3

*

Port4

*

Rate

*

Async

EIA

(Mux Enabled only)

(Singleport mode

only)

(Singleport mode

only)

(Singleport mode

only)

*

 Not shown when the Digital Bridge configuration option is enabled.

DeviceHS

VF

Identity

DTE

Backup

Options

Record

Major

Minor

Status

Dial

Thresh

Security

Port1

Port2

Port3

Port4

SigQual

RcvLevel

Sig/Noise

NrEchLv

FarEchLv

FarEchDel

EchoFreqOff

Phase Hts

Impul Hts

DropOuts

Retrains

Phas Jtr

NonLnear

FreqOffset

Gain Hts

Ser#

Mod#

FRev

HPt#

FPt#

Country

LSD

DTR

DSR

Tst

TXD

RXD

RTS

CTS

Line = Pri 4W APL

Line = Pri 2W APL

Line = Bkup 2W APL

Line = Dial Backup

Line = Dial ONLY

Line = No Sync

Display

Clear

Display Clear

Service_Log

Port Select

(Multiport

mode)

SDC

Tx

Rx

DTE Rate

Cmp Ratio

Efficiency

V.34

TxRate

RxRate

SymbolRate

TxLevel

AsymRate

Содержание 3920Plus

Страница 1: ... Models 3920Plus and 3921Plus Technical Reference Manual Document No 3920 A2 GH30 NOTE Do not download firmware with a release number lower than 4 0 to a Model 3920 A2 xxx modem Model 3920Plus modems support a wide range of modulation schemes and offer control using either AT commands the diagnostic control panel DCP or the optional COMSPHERE 6700 and 6800 Series Network Management Systems NMS The...

Страница 2: ...your geographic area COMSPHERE 3920Plus Modem The Model 3920Plus singleport modem is a standalone modem Figure 1 capable of either 4 wire 2 wire leased line or dial operation This modem is controlled using either AT commands or the DCP The DCP consists of a liquid crystal display LCD three function keys four directional keys and a row of 13 LED status indicators For a better understanding of DCP o...

Страница 3: ...ine configurations RJ11C for dial permissive configurations One 8 position 8 wire modular cord for leased backup purposes Model 3920Plus Modem Installation Before installing your modem read the Important Safety Instructions on page 10 Make sure your installation site is clean and well ventilated Allow space around the modem for installing cables and telephone cords and make sure the modem is locat...

Страница 4: ...es to the Model 3920Plus Modem Figure 2 illustrates the Model 3920Plus modem cable connections For pin assignments refer to Appendix C in the Technical Reference Manual 97 14677 01 DB 25 P CONNECTOR FOR DATA TERMINAL EQUIPMENT OPERATION SUB MINIATURE 4 POSITION PLUG FOR NETWORK MANAGEMENT SYSTEM OPERATION POWER SUPPLY 6 POSITION PLUG FOR PERMISSIVE DIAL NETWORK OPERATION 8 POSITION PLUG FOR LEASED...

Страница 5: ...2 3 Connect the power module to an ac power outlet Leased Line Network Connection Use the following steps to connect the leased line network interface 1 Insert the 8 position 8 conductor modular plug into the jack labeled LEASED Figure 2 2 Insert the other end of the modular cord into the leased line network interface 3 If the Model 3920Plus has a backup line follow the steps listed in the Dial Ba...

Страница 6: ... Feature Number 3600 F3 300 Installation Instructions Document No 3610 A2 GZ45 for a description of the 3600 Hubbing Device Installation for the 3920Plus is the same as for the 3610 DSU 2 Connect the 3600 Hubbing Device to the network management system Figure G 5 in Appendix G of the Technical Reference Manual Removing and Replacing the Model 3920Plus Modem To remove and replace the Model 3920Plus...

Страница 7: ...e modem passes the power up self test configure it for operation using one of the six factory preset configurations The Model 392xPlus modems have six factory preset templates that contain the most commonly used configuration options straps for Synchronous Leased Answer or Originate Asynchronous Leased Answer or Originate Trellis Multipoint Control or Tributary Asynchronous Dial Synchronous Dial a...

Страница 8: ...ode 4 Choose Function appears and displays the Edit and Save functions 5 Press the F3 key Save to save the new factory preset configuration to one of three configuration areas Active Saved Customer 1 or Customer 2 These three configuration areas are nonvolatile memory locations Active Saved contains the most recently saved changes to any configuration options In the event of power loss the modem r...

Страница 9: ...p Loc_Digital_Loop Pattern Singleport mode only 97 14651 04 Speaker Reset Data_Stream EIA_LEDS Make_Busy or RemoveMakeBusy Service_Line or DiscServLine Download_Code DownloadSoftware VF_Thresh_Update 3921Plus only Edit StrapGroup Set_Access_Ctrl Reset_Security Admin Password EditPassWdTable Set_Answer_Sec Set_Orig_Secur Set_Admin_PsWd DTE_Interface DTE_Dialer Line_Dialer Leased_Line Test Security ...

Страница 10: ...able Safety Standards and regulatory requirements of the country in which it is installed If necessary consult with the appropriate regulatory agencies and inspection authorities to ensure compliance 7 Input power to this product must be provided by one of the following 1 a UL Listed CSA Certified power source with a Class 2 or Limited Power Source LPS output for use in North America or 2 a certif...

Страница 11: ...GENCES DU RÈGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA Government Requirements and Equipment Return Certain governments require that instructions pertaining to modem connection to the public switched telephone network be included in the installation and operation manual Specific instructions are listed in the following sections United States Notice to Users of the Public Switched Telephone Netwo...

Страница 12: ...riffs Contact the state public utility commission public service commission or corporation commission for information 9 The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device to send any message via a telephone fax machine unless such a message clearly contains in a margin at the top or bottom of each transmitted page or on the f...

Страница 13: ... each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all devices does not exceed 100 If your equipment is in need of repair refer to the procedure in Government Requ...

Страница 14: ... 3920 A2 GK47 10 3920 A2 GK47 10 ...

Отзывы: