background image

21

Power-on Setting

Normal mode: 

Pressing and holding the power button is required to turn on the 

powered ZHIYUN MOLUS G60.

Live mode: 

The powered ZHIYUN MOLUS G60 can be turned on without pressing 

any buttons.
You can customize the way to turn on ZHIYUN MOLUS G60 at the power-on 
setting. The default mode is Normal mode. When entering the power-on setting 
interface, you can turn the brightness knob to select the mode and single-press 
the brightness knob to save and exit the setting.

Power-on Setting

Normal Mode

Live Mode

Current Mode

How to Use ZHIYUN MOLUS G60

1. When ZHIYUN MOLUS G60 is charging via a USB charger, the Live mode will 

be disabled.

2. When the power-on mode of ZHIYUN MOLUS G60 is in Live mode, the way 

the user turns off the device may cause the power-on mode to change:

① When simply unplugging the device to turn off, the power-on mode will 

stay the same as the Live mode.

② When pressing and holding the power button to turn off, the power-on 

mode will be switched to Normal mode. To switch back to Live mode, 
please adjust in the power-on setting.

Содержание MOLUS G60

Страница 1: ...Quick Keyword Search Enter the keyword in the search box and hit the search button Quick Jump between Chapters Click the title of a specific chapter on the Contents to jump to it Reading software such...

Страница 2: ...ZHIYUN MOLUS G60 User Guide Z H I Y U N E N v 1 0 0...

Страница 3: ...r hereinafter referred to as reflector Installing the Reflector 7 Removing the Reflector 7 Installing the Tripod Installing the Tripod 8 Installing and Removing ZHIYUN Mini Softbox hereinafter referre...

Страница 4: ...The Umbrella 15 Installing and Removing ZHIYUN Extension Plate hereinafter referred to as extension plate How to Use ZHIYUN MOLUS G60 Buttons and Knobs 19 Display Screen 20 Operation Instruction 20 Po...

Страница 5: ...IYUN MOLUS G60 Never use the product in the rain or a humid environment If water accidentally enters the device when using please stop using it immediately and contact the company or authorized mainte...

Страница 6: ...s product to avoid damage to this product 6 Protect the product from dust and sand during use 7 Before storing this product please make sure it is completely cooled and store it in a dry and ventilate...

Страница 7: ...e product package In case that any item is found missing please contact ZHIYUN or your local selling agent ZHIYUN MOLUS G60 x1 ZHIYUN Mini Reflector ZY Mount x1 DC Power Adapter x1 ZHIYUN Dome Diffusi...

Страница 8: ...4 Product List Grid x1 Storage Bag x1 Items marked are only included in ZHIYUN MOLUS G60 Combo...

Страница 9: ...60 Get to Know ZHIYUN MOLUS G60 Fan Type C Power Supply Firmware Upgrade Port Display Screen Brightness Knob DC Power Supply Port Bracket 1 4 Threaded Hole Color Temperature Knob Air Outlet Power Butt...

Страница 10: ...screen in real time When the input supply power is insufficient it is unable to adjust the brightness of ZHIYUN MOLUS G60 to 100 Power Supply USB charger and USB Type C cable are not provided AC Powe...

Страница 11: ...G60 accessory mount Install the reflector to the ZHIYUN MOLUS G60 and rotate the reflector clockwise until you hear a click sound The reflector is then installed Installing the Reflector Toggle the lo...

Страница 12: ...drive the bracket screw firmly Align the 1 4 screw of the tripod with the 1 4 threaded hole of the bracket and make sure a firm installation To adjust the angle you can loosen the bracket screw and ro...

Страница 13: ...60 accessory mount Install the softbox to the ZHIYUN MOLUS G60 and rotate the softbox as shown in the image until you hear a click sound Loosen the softbox straps push the axis to the right as shown i...

Страница 14: ...oving the Softbox Remove the grid from the softbox and unlock the softbox mount swivel as shown in the image Toggle the lock to another side while turning the softbox as shown in the image Remove the...

Страница 15: ...diffusion with the reflector Engage the groove ring of the dome diffusion in the reflector Removing Dome Diffusion You can remove the dome diffusion from the reflector with your hand Installing and Re...

Страница 16: ...se until you hear a click sound Align the standard reflector mount with the adapter mount and install the standard reflector to the adapter Turn the standard reflector counterclockwise until the refle...

Страница 17: ...g the adapter to a softbox with a Bowens mount the diameter of the softbox should be equal to or less than 30cm and the weight should be equal to or less than 1 3kg Bowens Mount Adapter ZY Mount A Ins...

Страница 18: ...the top of the adapter and turn the standard reflector as shown in the image Remove the reflector from the adapter Press and hold the lock at the gap of the adapter as shown in the image while turnin...

Страница 19: ...Insert the umbrella handle into the umbrella hole of the adapter and turn the knob clockwise Turn counterclockwise to unlock and pull out the umbrella handle Bowens Mount Adapter ZY Mount A Instructi...

Страница 20: ...ht stand Align the 1 4 threaded hole of the ZHIYUN MOLUS G60 bracket with the 1 4 threaded hole of the extension plate Fix the ZHIYUN MOLUS G60 on the extension plate with the screw You can connect mu...

Страница 21: ...17 Installing and Removing ZHIYUN Extension Plate hereinafter referred to as extension plate...

Страница 22: ...18 Installing and Removing ZHIYUN Extension Plate hereinafter referred to as extension plate ZHIYUN extension plate is sold separately...

Страница 23: ...de to Live mode In the power on setting interface Turn counterclockwise Decrease brightness value Switch from Live mode to Normal mode In the power on setting interface Single press Quick setting of b...

Страница 24: ...ingle press brightness color temperature knob for quick adjustment of brightness color temperature Turn the brightness color temperature knob clockwise counterclockwise to fine tune brightness color t...

Страница 25: ...ress the brightness knob to save and exit the setting Power on Setting Normal Mode Live Mode Current Mode How to Use ZHIYUN MOLUS G60 1 When ZHIYUN MOLUS G60 is charging via a USB charger the Live mod...

Страница 26: ...irmware and download 2 Unzip the firmware for the files with the ptz file extension 3 Connect the Type C port of ZHIYUN MOLUS G60 to the USB port of the computer with the USB Type C cable 4 Open Zhiyu...

Страница 27: ...23 Firmware Upgrade...

Страница 28: ...ated Output Voltage Current 24V 2 7A Lab Data 1 The data is collected in the following conditions No reflectors 25 temperature indoor illuminance lower than 0 1lux test distance 1m and the color tempe...

Страница 29: ...e or your place of purchase for detailed warranty information 1 Products subjected to unauthorized repair misuse collision neglect mishandling soaking accident and unauthorized alteration 2 Products s...

Страница 30: ...ber Address Sales Information Sales date Product Serial Number Distributor Name Distributor s Contact Number First Maintenance Record Service Date Repairman Signature Cause of Problem Service Result S...

Страница 31: ...27 Website Weibo Facebook Zhiyun Support Youtube Google Youku Vimeo Facebook Zhiyun Tech Wechat Instagram Contact Card...

Страница 32: ...hereunder may be trademarks or registered trademarks of their respective holders Copyright 2022 ZHISHEN All rights reserved Tel 86 400 900 6868 USA Hotline 1 808 319 6137 9 00 18 00 GMT 7 Mon Fri Eur...

Страница 33: ......

Отзывы: